Furnace, kiln & high-temp zone
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Product
SiD 300/500 V combines an IEC 60228 Class 1 solid tinned copper conductor with halogen-free red-oxide 180 °C silicone rubber insulation for rigid high-temperature control panels, saunas, and heating appliances.
Typical values for this cable type, based on DIN VDE 0250-502 · IEC 60228 Class 1 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.
Application fit
SiD 300/500 V combines an IEC 60228 Class 1 solid tinned copper conductor with halogen-free red-oxide 180 °C silicone rubber insulation for rigid high-temperature control panels, saunas, and heating appliances.
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Stable 300/500 V SiR construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-aged 300/500 V SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Compact flame-retardant 300/500 V SiR geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
300/500 V SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300/500 V SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of SiD 300/500 V Solid: IEC 60228 Class 1 solid tinned annealed copper, Red-oxide halogen-free 180 °C silicone rubber insulation, and Red-oxide 180 °C halogen-free silicone rubber outer insulation.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 1 solid tinned annealed copperIEC 60228 Class 1 |
| 2 | Extruded insulation | Red-oxide halogen-free 180 °C silicone rubber insulationDIN VDE 0250-502 |
Single-conductor high-temperature wire with extruded Red-oxide halogen-free 180 °C silicone rubber insulation.
Technical data
Sizes
| Conductor mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×0.5 mm² | 2.0 | 36.70 | 5 | 14 | 16 |
| 1×0.75 mm² | 2.2 | 24.80 | 7 | 17 | 18 |
| 1×1 mm² | 2.3 | 18.20 | 10 | 21 | 18 |
| 1×1.5 mm² | 2.6 | 12.20 | 14 | 26 | 21 |
| 1×2.5 mm² | 3.4 | 7.56 | 24 | 43 | 27 |
| 1×4 mm² | 3.9 | 4.70 | 38 | 66 | 31 |
| 1×6 mm² | 4.4 | 3.11 | 58 | 97 | 35 |
| 1×10 mm² | 5.6 | 1.84 | 96 | 159 | 45 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 1 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +180 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 180 °C Continuous Silicone · Halogen-Free Self-Extinguishing | Type approval |
Marking & supply
Sheath marking