Switchgear & control cabinet wiring
Compact 300 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
M17/176-00002 PFA Twinax delivers two 24 AWG silver-plated high-strength copper-alloy conductors in PTFE insulation, ≥ 90% silver-plated copper braid, and a blue PFA jacket built for MIL-STD-1553B avionics data buses.
Typical values for this cable type, based on MIL-DTL-17/176-00002 · MIL-STD-1553B · 77 Ω ± 7 Ω Twinax — confirmed in the datasheet and quotation for your order.
Application fit
M17/176-00002 PFA Twinax delivers two 24 AWG silver-plated high-strength copper-alloy conductors in PTFE insulation, ≥ 90% silver-plated copper braid, and a blue PFA jacket built for MIL-STD-1553B avionics data buses.
Compact 300 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Stable 300 V PTFE/PFA construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Low-weight, high-temperature 300 V PTFE/PFA construction meets compact avionics racks, flight-control looms, and aerospace harnesses.
Controlled-impedance 300 V construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.
300 V PTFE/PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V PTFE/PFA build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of M17/176-00002 PFA Twinax: ASTM B298 Class K stranded silver-plated annealed copper, Extruded PTFE fluoropolymer (white & blue 77 Ω pair), and Blue 200 °C chemical-resistant extruded PFA outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu |
| 2 | Dielectric / core insulation | Extruded PTFE fluoropolymer (white & blue 77 Ω pair)MIL-DTL-17/176-00002 |
| 3 | Core assembly & separator | Concentric cabled core assembly with low-friction fleece/polyester separator tapeMIL-DTL-17/176-00002 |
| 4 | Metallic EMC screen | Overall ≥ 90% silver-plated copper wire braid shieldEMC ≥ 85% shield |
| 5 | Outer sheath | Blue 200 °C chemical-resistant extruded PFA outer jacket200 °C Continuous PFA |
White and blue 77 Ω PTFE twisted pair under ≥ 90% silver-plated copper braid and PFA jacket.
Technical data
Sizes
| Impedance · Pair | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 77 Ω · 2×24 AWG (MIL-STD-1553B) | 3.3 | 98.00 | 16 | 30 | 33 |
| 77 Ω · 2×22 AWG (Extended Run) | 3.9 | 62.00 | 23 | 42 | 39 |
| 77 Ω · 2×20 AWG (Long Bus) | 4.6 | 39.00 | 32 | 58 | 46 |
| 77 Ω · 2×26 AWG (Lightweight) | 2.8 | 155.00 | 12 | 23 | 28 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B298 Silver Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -65 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 200 °C Continuous PFA · ≥ 90% Silver-Cu Braid | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.