ANSI Type K Duplex FEP 200 °C Thermocouple CableASTM E230 / ANSI MC96.1 parallel FEP-insulated 200 °C Type K cable

ANSI Type K Duplex FEP 200 °C pairs matched Chromel (+) / Alumel (-) thermocouple alloy conductors in ANSI yellow/red FEP insulation and a brown extruded FEP flat outer jacket for 200 °C process sensing.

Flame-retardant
Oil-resistant
Approved
Order designation
ANSI Type K FEP Cable 2×20 AWG (Type K)
Outer Ø
3.2 mm
Max. R20
1,930.00 Ω/km
Weight
24 kg/km
Min. bend R
26 mm
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Test voltage 1.5 kV AC
Temp. (fixed)
-75°C…+200°C
Flexing: -40 °C to +200 °C
Insulation
FEP
Extruded FEP fluoropolymer (ANSI
Min. bend radius
8 × OD
Fixed & equipment routing
Conductor
Type K NiCr/NiAl
Per ASTM E230
Size range
2×24–2×14
5 standard configurations

Typical values for this cable type, based on ASTM E230 · ANSI MC96.1 Type K · IEC 60584-3 — confirmed in the datasheet and quotation for your order.

Application fit

Is ANSI Type K FEP Cable right for your machine?

ANSI Type K Duplex FEP 200 °C pairs matched Chromel (+) / Alumel (-) thermocouple alloy conductors in ANSI yellow/red FEP insulation and a brown extruded FEP flat outer jacket for 200 °C process sensing.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.

Fixed installation

Suitable

Stable 300 V FEP construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 300 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Process instrumentation & DCS field loop

Suitable

Low-noise 300 V FEP pair/core geometry preserves 4–20 mA and sensor signals from field transmitters to DCS marshalling cabinets.

Energy chain / drag chain

Not suitable

300 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableIndustrial kilns, autoclaves & heat-treatment furnacesChemical reactors, refineries & process skidsAerospace composite curing & thermal testingSemiconductor, pharmaceutical & laboratory chambers

Construction

Layer by layer

Representative construction of ANSI Type K FEP Cable: Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductors, Extruded FEP fluoropolymer (ANSI yellow + / red -), and Brown chemical- & moisture-resistant extruded FEP flat outer jacket.

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorMatched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductorsASTM E230 / IEC 60584
2Dielectric / core insulationExtruded FEP fluoropolymer (ANSI yellow + / red -)ASTM E230
3Outer sheathBrown chemical- & moisture-resistant extruded FEP flat outer jacketUL VW-1 Flame

ANSI Type K FEP Cable ANSI Type K

ANSI MC96.1 yellow (+) Chromel and red (-) Alumel parallel duplex fluoropolymer thermocouple cores.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ASTM E230 · ANSI MC96.1 Type K · IEC 60584-3. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V
Test voltage
1.5 kV AC
Conductor
Type K NiCr/NiAl
Insulation
Extruded FEP fluoropolymer (ANSI yellow +
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-75 °C to +200 °C
Temp. range (flexing)
-40 °C to +200 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
8 × OD (fixed)

Resistance

Flame / fire rating
UL VW-1 Flame
Thermal / chemical
Chemical & Moisture Proof FEP
Mechanical / special
±1.1 °C Special Limits
Outer finish
Brown chemical- & moisture-resistant

Sizes

ANSI Type K Duplex Thermocouple (AWG)
Pair ×
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
2×24 AWG (Type K)2.54,880.0041420
2×20 AWG (Type K)3.21,930.00102426
2×18 AWG (Type K)3.81,215.00163630
2×16 AWG (Type K)4.4765.00255235
2×14 AWG (Type K)5.2480.00397642
  • Conductor DC resistance R20 at 20 °C per ASTM E230 / IEC 60584.
  • For flat cable geometries, Outer Ø indicates nominal bending-plane thickness; minimum bending radius is 8 × nominal thickness.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test1.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM E230 / IEC 60584 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -75 °C to +200 °C continuousPer production lot
Flame, chemical & mechanical qualificationUL VW-1 Flame · Chemical & Moisture Proof FEPType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ASTM E230ANSI MC96.1 Type KIEC 60584-3EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

ANSI Type K FEP Cable 300 V TEBAOFLEX.COM [ASTM E230] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export drums
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes ANSI Type K FEP Cable suited for 300 V and -75 °C to +200 °C operation?
ANSI Type K FEP Cable combines Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductors with Extruded FEP fluoropolymer (ANSI yellow + / red -) and Brown chemical- & moisture-resistant extruded FEP flat outer jacket. Chemically inert FEP fluoropolymer withstands corrosive vapours, steam, and continuous 200 °C kiln sensing.
What is the minimum bending radius of ANSI Type K FEP Cable during installation?
Maintain a minimum bending radius of 8 × OD across -40 °C to +200 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can ANSI Type K FEP Cable be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies ANSI Type K FEP Cable cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany ANSI Type K FEP Cable?
ANSI Type K FEP Cable conforms to ASTM E230, ANSI MC96.1 Type K, IEC 60584-3 (UL VW-1 Flame) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for ANSI Type K FEP Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ANSI Type K Duplex FEP 200 °C Thermocouple Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote