Furnace, kiln & high-temp zone
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Product
SiF/GL 300/500 V armours standard 180 °C halogen-free SiF silicone rubber insulation over Class 5 tinned copper with a dense varnished fibreglass outer braid (GL) for heavy mechanical wear in kilns and motors.
Typical values for this cable type, based on DIN VDE 0250-502 · IEC 60228 Class 5 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.
Application fit
SiF/GL 300/500 V armours standard 180 °C halogen-free SiF silicone rubber insulation over Class 5 tinned copper with a dense varnished fibreglass outer braid (GL) for heavy mechanical wear in kilns and motors.
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Flexible 300/500 V SiR heat-resistant insulation terminates cleanly inside motor junction boxes, heaters, and hot windings.
Thermal-aged 300/500 V SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
High-dielectric 300/500 V SiR winding insulation handles compact submersible, traction, and industrial motor stator slots reliably.
300/500 V SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300/500 V SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of SiF/GL 300/500 V: IEC 60228 Class 5 flexible tinned annealed copper, Halogen-free 180 °C silicone rubber primary insulation, and Off-white varnished fibreglass outer braid over silicone (silicone/glass).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5 |
| 2 | Primary insulation | Halogen-free 180 °C silicone rubber primary insulationDIN VDE 0250-502 |
| 3 | Fibreglass outer braid | Off-white varnished fibreglass outer braid over silicone (silicone/glass)180 °C Silicone + Glass Braid |
Single high-temperature conductor insulated in silicone rubber and protected by a varnished fibreglass outer braid.
Technical data
Sizes
| Conductor mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 6×D mm |
|---|---|---|---|---|---|
| 1×0.5 mm² | 2.6 | 40.09 | 5 | 14 | 16 |
| 1×0.75 mm² | 2.9 | 26.73 | 7 | 17 | 17 |
| 1×1 mm² | 3.0 | 20.05 | 10 | 22 | 18 |
| 1×1.5 mm² | 3.3 | 13.67 | 14 | 29 | 20 |
| 1×2.5 mm² | 4.2 | 8.20 | 24 | 49 | 25 |
| 1×4 mm² | 4.8 | 5.09 | 38 | 73 | 29 |
| 1×6 mm² | 5.4 | 3.39 | 58 | 106 | 32 |
| 1×10 mm² | 6.7 | 1.96 | 96 | 172 | 40 |
| 1×16 mm² | 7.8 | 1.24 | 154 | 266 | 47 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +180 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 180 °C Silicone + Glass Braid · High Cut-Through Resistance | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.