Furnace, kiln & high-temp zone
Thermal-rated 600 V Mica build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.
Product
MGT 450 °C UL 5128 / 5107 combines 27% nickel-plated copper with phlogopite mica tapes and a tan heat-cured fibreglass outer braid rated 600 V and +450 °C for commercial ovens, industrial kilns, and cartridge heaters.
Typical values for this cable type, based on UL AWM Style 5128 · UL AWM Style 5107 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.
Application fit
MGT 450 °C UL 5128 / 5107 combines 27% nickel-plated copper with phlogopite mica tapes and a tan heat-cured fibreglass outer braid rated 600 V and +450 °C for commercial ovens, industrial kilns, and cartridge heaters.
Thermal-rated 600 V Mica build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.
Durable 600 V Mica geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Thermal-aged 600 V Mica insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
High-dielectric 600 V Mica winding insulation handles compact submersible, traction, and industrial motor stator slots reliably.
600 V Mica construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600 V Mica outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of MGT 450°C UL 5128/5107 Wire: ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp), Helically wrapped phlogopite mica glass tape dielectric (MGT), and Tan high-temperature treated fibreglass outer braid (mica/glass).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B355 Class K stranded nickel-plated copper (27% Ni high-temp)ASTM B355 Nickel Cu |
| 2 | Mica / PTFE tape dielectric | Helically wrapped phlogopite mica glass tape dielectric (MGT)UL AWM Style 5128 |
| 3 | Fibreglass outer braid | Tan high-temperature treated fibreglass outer braid (mica/glass)450 °C Continuous MGT |
Single high-temperature conductor wrapped in overlapping thermal dielectric tape and varnished fibreglass outer braid.
Technical data
Sizes
| Conductor AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×18 AWG | 2.7 | 25.984 | 8 | 20 | 22 |
| 1×16 AWG | 3.0 | 16.464 | 12 | 28 | 24 |
| 1×14 AWG | 3.5 | 10.158 | 19 | 43 | 28 |
| 1×12 AWG | 4.0 | 6.395 | 31 | 66 | 32 |
| 1×10 AWG | 4.6 | 4.021 | 49 | 99 | 37 |
| 1×8 AWG | 5.4 | 2.531 | 78 | 153 | 43 |
| 1×6 AWG | 6.4 | 1.590 | 124 | 237 | 51 |
| 1×4 AWG | 7.7 | 0.999 | 197 | 371 | 62 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric withstand test | 2.5 kV AC without breakdown | Every manufactured length |
| Continuity & conductor DC resistance | Per ASTM B355 Nickel Cu at 20 °C | Every drum / assembly |
| Sample tests | ||
| Tensile, dimensional & pressure check | Rated -60 °C to +450 °C continuous | Per production lot |
| Environmental, thermal & mechanical qualification | 450 °C Continuous MGT · UL VW-1 Flame | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.