Furnace, kiln & high-temp zone
Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Product
FEP/C/FEP 4×0.22 RTD features four colour-coded silver-plated copper conductors (2× red, 2× white) in FEP insulation, ≥ 85% silver/tinned copper braid, and a white chemical-proof FEP jacket for 4-wire Pt100 RTD sensors.
Typical values for this cable type, based on IEC 60751 (Pt100 RTD) · DIN VDE 0812 · UL VW-1 — confirmed in the datasheet and quotation for your order.
Application fit
FEP/C/FEP 4×0.22 RTD features four colour-coded silver-plated copper conductors (2× red, 2× white) in FEP insulation, ≥ 85% silver/tinned copper braid, and a white chemical-proof FEP jacket for 4-wire Pt100 RTD sensors.
Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.
Stable 300 V FEP construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Low-noise 300 V FEP pair/core geometry preserves 4–20 mA and sensor signals from field transmitters to DCS marshalling cabinets.
Thermal-aged 300 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
300 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of FEP/C/FEP 4×0.22 RTD: IEC 60228 Class 5 flexible silver-plated annealed copper, Extruded FEP fluoropolymer (2× red, 2× white per IEC 60751), and White chemical- & steam-resistant extruded FEP outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible silver-plated annealed copperIEC 60228 Class 5 |
| 2 | Dielectric / core insulation | Extruded FEP fluoropolymer (2× red, 2× white per IEC 60751)IEC 60751 (Pt100 RTD) |
| 3 | Core assembly & separator | Concentric cabled core assembly with low-friction fleece/polyester separator tapeIEC 60751 (Pt100 RTD) |
| 4 | Metallic EMC screen | Overall ≥ 85% tinned/silver-plated copper braid shieldEMC ≥ 85% shield |
| 5 | Outer sheath | White chemical- & steam-resistant extruded FEP outer sheath200 °C Continuous FEP |
Four IEC 60751 silver-plated copper cores (2× red, 2× white) under overall braid and FEP jacket.
Technical data
Sizes
| Cores × mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 4×0.22 mm² (Pt100) | 4.2 | 90.64 | 18 | 36 | 42 |
| 4×0.25 mm² (Pt100) | 4.5 | 81.37 | 21 | 41 | 45 |
| 4×0.34 mm² (Pt100) | 4.9 | 59.23 | 26 | 49 | 49 |
| 4×0.5 mm² (Pt100) | 5.5 | 40.09 | 34 | 62 | 55 |
| 4×0.75 mm² (Pt100) | 6.2 | 26.73 | 45 | 79 | 62 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -75 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 200 °C Continuous FEP · ≥ 85% EMC Braid Screen | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.