Contact

FEP/C/FEP 4×0.22 mm² 200 °C Pt100 RTD Sensor Cable4-wire silver-plated copper screened FEP/FEP 200 °C Pt100 RTD cable

FEP/C/FEP 4×0.22 RTD features four colour-coded silver-plated copper conductors (2× red, 2× white) in FEP insulation, ≥ 85% silver/tinned copper braid, and a white chemical-proof FEP jacket for 4-wire Pt100 RTD sensors.

Flame-retardant
Low-EMC design
EMC screen
Oil-resistant
Order designation
FEP/C/FEP 4×0.22 RTD 4×0.22 mm² (Pt100)
Outer Ø
4.2 mm
Max. R20
90.64 Ω/km
Weight
36 kg/km
Min. bend R
42 mm
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Test voltage 1.5 kV AC
Temp. (fixed)
-75°C…+200°C
Flexing: -40 °C to +200 °C
EMC / Shield
≥ 85% Braid
Overall ≥ 85% tinned/silver-plated
Min. bend radius
10 × OD
Fixed & equipment routing
Conductor
Silver-Plated Cu
Per IEC 60751 (Pt100 RTD)
Size range
4×0.22–4×0.75
5 standard configurations

Typical values for this cable type, based on IEC 60751 (Pt100 RTD) · DIN VDE 0812 · UL VW-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is FEP/C/FEP 4×0.22 RTD right for your machine?

FEP/C/FEP 4×0.22 RTD features four colour-coded silver-plated copper conductors (2× red, 2× white) in FEP insulation, ≥ 85% silver/tinned copper braid, and a white chemical-proof FEP jacket for 4-wire Pt100 RTD sensors.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.

Fixed installation

Suitable

Stable 300 V FEP construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.

Process instrumentation & DCS field loop

Suitable

Low-noise 300 V FEP pair/core geometry preserves 4–20 mA and sensor signals from field transmitters to DCS marshalling cabinets.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 300 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

300 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial Automation CableIndustrial kilns, autoclaves & heat-treatment furnacesChemical reactors, refineries & process skidsAerospace composite curing & thermal testingSemiconductor, pharmaceutical & laboratory chambers

Construction

Layer by layer

Representative construction of FEP/C/FEP 4×0.22 RTD: IEC 60228 Class 5 flexible silver-plated annealed copper, Extruded FEP fluoropolymer (2× red, 2× white per IEC 60751), and White chemical- & steam-resistant extruded FEP outer sheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 5 flexible silver-plated annealed copperIEC 60228 Class 5
2Dielectric / core insulationExtruded FEP fluoropolymer (2× red, 2× white per IEC 60751)IEC 60751 (Pt100 RTD)
3Core assembly & separatorConcentric cabled core assembly with low-friction fleece/polyester separator tapeIEC 60751 (Pt100 RTD)
4Metallic EMC screenOverall ≥ 85% tinned/silver-plated copper braid shieldEMC ≥ 85% shield
5Outer sheathWhite chemical- & steam-resistant extruded FEP outer sheath200 °C Continuous FEP

FEP/C/FEP 4×0.22 RTD 4-Wire Pt100

Four IEC 60751 silver-plated copper cores (2× red, 2× white) under overall braid and FEP jacket.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60751 (Pt100 RTD) · DIN VDE 0812 · UL VW-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V
Test voltage
1.5 kV AC
Conductor
Silver-Plated Cu
Insulation
Extruded FEP fluoropolymer (2× red, 2×
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-75 °C to +200 °C
Temp. range (flexing)
-40 °C to +200 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
10 × OD (fixed)

Resistance

Flame / fire rating
200 °C Continuous FEP
Thermal / chemical
≥ 85% EMC Braid Screen
Mechanical / special
Acid, Steam & Oil Proof
Outer finish
White chemical- & steam-resistant

Sizes

4-Wire Screened Pt100 RTD (mm²)
Cores ×
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
10×D mm
4×0.22 mm² (Pt100)4.290.64183642
4×0.25 mm² (Pt100)4.581.37214145
4×0.34 mm² (Pt100)4.959.23264949
4×0.5 mm² (Pt100)5.540.09346255
4×0.75 mm² (Pt100)6.226.73457962
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 5.
  • Minimum bending radius calculated at 10 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test1.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer IEC 60228 Class 5 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -75 °C to +200 °C continuousPer production lot
Flame, chemical & mechanical qualification200 °C Continuous FEP · ≥ 85% EMC Braid ScreenType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60751 (Pt100 RTD)DIN VDE 0812UL VW-1EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

FEP/C/FEP 4×0.22 RTD 300 V TEBAOFLEX.COM [IEC 60751 (Pt100 RTD)] [Size] [Metre mark]
Delivery form
Cut-to-length or wooden export drums
Standard lengths
100 m · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes FEP/C/FEP 4×0.22 RTD suited for 300 V and -75 °C to +200 °C operation?
FEP/C/FEP 4×0.22 RTD combines IEC 60228 Class 5 flexible silver-plated annealed copper with Extruded FEP fluoropolymer (2× red, 2× white per IEC 60751) and White chemical- & steam-resistant extruded FEP outer sheath. Balanced 4-wire geometry eliminates lead-resistance error on high-precision Pt100/Pt1000 temperature probes.
What is the minimum bending radius of FEP/C/FEP 4×0.22 RTD during installation?
Maintain a minimum bending radius of 10 × OD across -40 °C to +200 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can FEP/C/FEP 4×0.22 RTD be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies FEP/C/FEP 4×0.22 RTD cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany FEP/C/FEP 4×0.22 RTD?
FEP/C/FEP 4×0.22 RTD conforms to IEC 60751 (Pt100 RTD), DIN VDE 0812, UL VW-1 (200 °C Continuous FEP) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for FEP/C/FEP 4×0.22 RTD

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FEP/C/FEP 4×0.22 mm² 200 °C Pt100 RTD Sensor Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote