Switchgear & control cabinet wiring
Compact 750 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
M17/93-00001 PFA Coax 250 °C features a silver-plated copper-clad steel centre conductor, solid PTFE dielectric (50 Ω), ≥ 95% silver-plated copper braid, and a translucent-tan PFA jacket for 250 °C RF interconnects.
Typical values for this cable type, based on MIL-DTL-17/93-00001 · RG-178 / RG-316 Class · 50 Ω ± 2 Ω Coax — confirmed in the datasheet and quotation for your order.
Application fit
M17/93-00001 PFA Coax 250 °C features a silver-plated copper-clad steel centre conductor, solid PTFE dielectric (50 Ω), ≥ 95% silver-plated copper braid, and a translucent-tan PFA jacket for 250 °C RF interconnects.
Compact 750 V PTFE/PFA profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Stable 750 V PTFE/PFA construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Low-weight, high-temperature 750 V PTFE/PFA construction meets compact avionics racks, flight-control looms, and aerospace harnesses.
Thermal-aged 750 V PTFE/PFA insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
750 V PTFE/PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR750 V PTFE/PFA build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of M17/93-00001 PFA Coax 250°C: ASTM B298 Class K stranded silver-plated annealed copper, Solid extruded PTFE fluoropolymer (50 Ω), and Translucent-tan 250 °C extruded PFA fluoropolymer outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu |
| 2 | Dielectric / core insulation | Solid extruded PTFE fluoropolymer (50 Ω)MIL-DTL-17/93-00001 |
| 3 | Metallic EMC screen | Overall ≥ 95% silver-plated copper wire braid shieldEMC ≥ 85% shield |
| 4 | Outer sheath | Translucent-tan 250 °C extruded PFA fluoropolymer outer jacket250 °C Continuous PFA |
Silver-plated centre conductor in 50 Ω PTFE dielectric inside braided silver-plated copper shield.
Technical data
Sizes
| Impedance · Style | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 50 Ω · 30 AWG SCCS (RG-178) | 1.8 | 780.00 | 5 | 14 | 18 |
| 50 Ω · 26 AWG SCCS (RG-316) | 2.5 | 276.00 | 10 | 21 | 25 |
| 50 Ω · 26 AWG Dual-Braid | 2.9 | 276.00 | 15 | 28 | 29 |
| 50 Ω · 19 AWG SCCS (RG-142) | 4.9 | 64.00 | 32 | 66 | 49 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B298 Silver Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -70 °C to +250 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 250 °C Continuous PFA · ≥ 95% Silver-Cu Braid | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.