Furnace, kiln & high-temp zone
Thermal-rated 300 V PFA insulation maintains dielectric safety across continuous high-temperature zones up to +260 °C.
Product
ANSI Type K Duplex PFA 260 °C uses matched NiCr/NiAl thermocouple alloy conductors with high-temperature PFA insulation and a translucent-tan extruded PFA flat outer jacket rated up to +260 °C continuous.
Typical values for this cable type, based on ASTM E230 · ANSI MC96.1 Type K · IEC 60584-3 — confirmed in the datasheet and quotation for your order.
Application fit
ANSI Type K Duplex PFA 260 °C uses matched NiCr/NiAl thermocouple alloy conductors with high-temperature PFA insulation and a translucent-tan extruded PFA flat outer jacket rated up to +260 °C continuous.
Thermal-rated 300 V PFA insulation maintains dielectric safety across continuous high-temperature zones up to +260 °C.
Stable 300 V PFA construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Thermal-aged 300 V PFA insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Low-noise 300 V PFA pair/core geometry preserves 4–20 mA and sensor signals from field transmitters to DCS marshalling cabinets.
300 V PFA construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300 V PFA outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of ANSI Type K PFA Cable: Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductors, High-temperature extruded PFA fluoropolymer (yellow + / red -), and Tan/natural chemical-proof 260 °C extruded PFA flat outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Matched ASTM E230 Type K Chromel (NiCr +) / Alumel (NiAl -) thermocouple alloy conductorsASTM E230 / IEC 60584 |
| 2 | Dielectric / core insulation | High-temperature extruded PFA fluoropolymer (yellow + / red -)ASTM E230 |
| 3 | Outer sheath | Tan/natural chemical-proof 260 °C extruded PFA flat outer jacketUL VW-1 Flame |
ANSI MC96.1 yellow (+) Chromel and red (-) Alumel parallel duplex fluoropolymer thermocouple cores.
Technical data
Sizes
| Pair × AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 2×24 AWG (Type K) | 2.5 | 4,880.00 | 4 | 14 | 20 |
| 2×20 AWG (Type K) | 3.2 | 1,930.00 | 10 | 24 | 26 |
| 2×18 AWG (Type K) | 3.8 | 1,215.00 | 16 | 36 | 30 |
| 2×16 AWG (Type K) | 4.4 | 765.00 | 25 | 52 | 35 |
| 2×14 AWG (Type K) | 5.2 | 480.00 | 39 | 76 | 42 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM E230 / IEC 60584 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -190 °C to +260 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | UL VW-1 Flame · 260 °C Continuous PFA | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.