Switchgear & control cabinet wiring
Compact 500 V PTFE/FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
LL142 Expanded-PTFE Coax pairs a silver-plated copper centre conductor and microporous expanded-PTFE (ePTFE) dielectric with double silver-plated copper shields and a blue FEP jacket for low-loss RF runs up to 18 GHz.
Typical values for this cable type, based on MIL-DTL-17 (ref.) · IEC 61196 · 50 Ω ± 1 Ω RF Coax — confirmed in the datasheet and quotation for your order.
Application fit
LL142 Expanded-PTFE Coax pairs a silver-plated copper centre conductor and microporous expanded-PTFE (ePTFE) dielectric with double silver-plated copper shields and a blue FEP jacket for low-loss RF runs up to 18 GHz.
Compact 500 V PTFE/FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Stable 500 V PTFE/FEP construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.
Low-weight, high-temperature 500 V PTFE/FEP construction meets compact avionics racks, flight-control looms, and aerospace harnesses.
Controlled-impedance 500 V construction delivers low-attenuation telemetry across industrial Ethernet, fieldbus, and control racks.
500 V PTFE/FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR500 V PTFE/FEP build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of LL142 50Ω ePTFE Coax: ASTM B298 Class K stranded silver-plated annealed copper, Low-loss microporous expanded PTFE (ePTFE, 50 Ω), and Blue 200 °C chemical-resistant extruded FEP outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu |
| 2 | Dielectric / core insulation | Low-loss microporous expanded PTFE (ePTFE, 50 Ω)MIL-DTL-17 (ref.) |
| 3 | Metallic EMC screen | Flat silver-plated copper strip + Al-foil + round SPC outer braidEMC ≥ 85% shield |
| 4 | Outer sheath | Blue 200 °C chemical-resistant extruded FEP outer jacketUp to 18 GHz Low-Loss |
Silver-plated centre conductor in 50 Ω PTFE dielectric inside braided silver-plated copper shield.
Technical data
Sizes
| Impedance · Centre | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 10×D mm |
|---|---|---|---|---|---|
| 50 Ω · 19 AWG SPC (ePTFE) | 5.0 | 27.20 | 34 | 64 | 50 |
| 50 Ω · 18 AWG SPC (ePTFE) | 5.6 | 21.50 | 42 | 78 | 56 |
| 50 Ω · 16 AWG SPC (ePTFE) | 6.4 | 13.60 | 56 | 102 | 64 |
| 50 Ω · 13 AWG SPC (ePTFE) | 8.5 | 6.80 | 92 | 168 | 85 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 1.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B298 Silver Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -65 °C to +200 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | Up to 18 GHz Low-Loss · > 90 dB Shielding | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.