Contact

DIN VDE 6YI1 205 °C FEP High-Temp Equipment WireDIN VDE 0207-6 6YI1 dark-blue 205 °C extruded FEP equipment wire

VDE 6YI1 205 °C FEP uses Class 5 silver/tinned copper conductors with VDE-compound 6YI1 dark-blue extruded FEP fluoropolymer insulation rated 300/500 V and 205 °C for European machinery, kilns, and heating fixtures.

Flame-retardant
Oil-resistant
Approved
Order designation
VDE 6YI1 205°C FEP 1×1.5 mm²
Outer Ø
2.3 mm
Max. R20
13.67 Ω/km
Weight
26 kg/km
Min. bend R
18.0 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Test voltage 2.5 kV AC
Temp. (fixed)
-100°C…+205°C
Flexing: -55 °C to +205 °C
Insulation
FEP
Dark-blue extruded FEP (6YI1)
Min. bend radius
8 × OD
Fixed & equipment routing
Conductor
Tinned Cu · Cl.5
Per DIN VDE 0207-6 (6YI1)
Size range
1×0.25–1×6
8 standard configurations

Typical values for this cable type, based on DIN VDE 0207-6 (6YI1) · IEC 60228 Class 5 · IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.

Application fit

Is VDE 6YI1 205°C FEP right for your machine?

VDE 6YI1 205 °C FEP uses Class 5 silver/tinned copper conductors with VDE-compound 6YI1 dark-blue extruded FEP fluoropolymer insulation rated 300/500 V and 205 °C for European machinery, kilns, and heating fixtures.

Switchgear & control cabinet wiring

Suitable

Compact 300/500 V FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 300/500 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +205 °C.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 300/500 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 300/500 V FEP geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Energy chain / drag chain

Not suitable

300/500 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

300/500 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of VDE 6YI1 205°C FEP: IEC 60228 Class 5 flexible tinned annealed copper, Dark-blue extruded FEP (6YI1) fluoropolymer insulation, and Dark-blue extruded FEP (6YI1) fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5
2Extruded insulationDark-blue extruded FEP (6YI1) fluoropolymer insulationDIN VDE 0207-6 (6YI1)

VDE 6YI1 205°C FEP Single-Core

Single-conductor high-temperature wire with extruded Dark-blue extruded FEP (6YI1) fluoropolymer insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0207-6 (6YI1) · IEC 60228 Class 5 · IEC 60332-1-2. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300/500 V
Test voltage
2.5 kV AC
Conductor
Tinned Cu · Cl.5
Insulation
Dark-blue extruded FEP (6YI1)
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-100 °C to +205 °C
Temp. range (flexing)
-55 °C to +205 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
8 × OD (fixed)

Resistance

Flame / fire rating
205 °C Compound 6YI1
Thermal / chemical
Weather & Solvent Proof
Mechanical / special
Zero Flame Propagation
Outer finish
Dark-blue extruded FEP (6YI1)

Sizes

Metric Single-Core Fluoropolymer Wire (mm²)
Conductor
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×0.25 mm²1.481.3721111.2
1×0.5 mm²1.640.0951413.0
1×0.75 mm²1.826.7371714.0
1×1 mm²2.020.05102116.0
1×1.5 mm²2.313.67142618.0
1×2.5 mm²3.18.20244625.0
1×4 mm²3.65.09387029.0
1×6 mm²4.23.395810434.0
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 5.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test2.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer IEC 60228 Class 5 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -100 °C to +205 °C continuousPer production lot
Flame, chemical & mechanical qualification205 °C Compound 6YI1 · Weather & Solvent ProofType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0207-6 (6YI1)IEC 60228 Class 5IEC 60332-1-2EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

VDE 6YI1 205°C FEP 300/500 V TEBAOFLEX.COM [DIN VDE 0207-6 (6YI1)] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
100 m · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes VDE 6YI1 205°C FEP suited for 300/500 V and -100 °C to +205 °C operation?
VDE 6YI1 205°C FEP combines IEC 60228 Class 5 flexible tinned annealed copper with Dark-blue extruded FEP (6YI1) fluoropolymer insulation and Dark-blue extruded FEP (6YI1) fluoropolymer outer insulation. DIN VDE 0207-6 6YI1 FEP compound ensures consistent 205 °C thermal aging in European OEM equipment.
What is the minimum bending radius of VDE 6YI1 205°C FEP during installation?
Maintain a minimum bending radius of 8 × OD across -55 °C to +205 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can VDE 6YI1 205°C FEP be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies VDE 6YI1 205°C FEP cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany VDE 6YI1 205°C FEP?
VDE 6YI1 205°C FEP conforms to DIN VDE 0207-6 (6YI1), IEC 60228 Class 5, IEC 60332-1-2 (205 °C Compound 6YI1) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for VDE 6YI1 205°C FEP

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

DIN VDE 6YI1 205 °C FEP High-Temp Equipment Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp