Switchgear & control cabinet wiring
Compact 300/500 V FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
VDE 6YI1 205 °C FEP uses Class 5 silver/tinned copper conductors with VDE-compound 6YI1 dark-blue extruded FEP fluoropolymer insulation rated 300/500 V and 205 °C for European machinery, kilns, and heating fixtures.
Typical values for this cable type, based on DIN VDE 0207-6 (6YI1) · IEC 60228 Class 5 · IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
VDE 6YI1 205 °C FEP uses Class 5 silver/tinned copper conductors with VDE-compound 6YI1 dark-blue extruded FEP fluoropolymer insulation rated 300/500 V and 205 °C for European machinery, kilns, and heating fixtures.
Compact 300/500 V FEP profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Thermal-rated 300/500 V FEP insulation maintains dielectric safety across continuous high-temperature zones up to +205 °C.
Thermal-aged 300/500 V FEP insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
Compact flame-retardant 300/500 V FEP geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
300/500 V FEP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300/500 V FEP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of VDE 6YI1 205°C FEP: IEC 60228 Class 5 flexible tinned annealed copper, Dark-blue extruded FEP (6YI1) fluoropolymer insulation, and Dark-blue extruded FEP (6YI1) fluoropolymer outer insulation.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5 |
| 2 | Extruded insulation | Dark-blue extruded FEP (6YI1) fluoropolymer insulationDIN VDE 0207-6 (6YI1) |
Single-conductor high-temperature wire with extruded Dark-blue extruded FEP (6YI1) fluoropolymer insulation.
Technical data
Sizes
| Conductor mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×0.25 mm² | 1.4 | 81.37 | 2 | 11 | 11.2 |
| 1×0.5 mm² | 1.6 | 40.09 | 5 | 14 | 13.0 |
| 1×0.75 mm² | 1.8 | 26.73 | 7 | 17 | 14.0 |
| 1×1 mm² | 2.0 | 20.05 | 10 | 21 | 16.0 |
| 1×1.5 mm² | 2.3 | 13.67 | 14 | 26 | 18.0 |
| 1×2.5 mm² | 3.1 | 8.20 | 24 | 46 | 25.0 |
| 1×4 mm² | 3.6 | 5.09 | 38 | 70 | 29.0 |
| 1×6 mm² | 4.2 | 3.39 | 58 | 104 | 34.0 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 5 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -100 °C to +205 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | 205 °C Compound 6YI1 · Weather & Solvent Proof | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.