Switchgear & control cabinet wiring
Compact 600 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Product
UL 5196 PTFE Glass Braid reinforces extruded PTFE insulation over nickel-plated copper with a high-temperature PTFE-impregnated fibreglass outer braid for severe mechanical abrasion in 250 °C industrial ovens and steelworks.
Typical values for this cable type, based on UL AWM Style 5196 · UL 758 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.
Application fit
UL 5196 PTFE Glass Braid reinforces extruded PTFE insulation over nickel-plated copper with a high-temperature PTFE-impregnated fibreglass outer braid for severe mechanical abrasion in 250 °C industrial ovens and steelworks.
Compact 600 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.
Thermal-rated 600 V PTFE insulation maintains dielectric safety across continuous high-temperature zones up to +250 °C.
Thermal-aged 600 V PTFE insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
High-dielectric 600 V PTFE winding insulation handles compact submersible, traction, and industrial motor stator slots reliably.
600 V PTFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600 V PTFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of UL 5196 PTFE Glass Wire: ASTM B355 Class K stranded nickel-plated annealed copper, Extruded PTFE fluoropolymer primary insulation, and Off-white PTFE-impregnated fibreglass outer braid (glass/fluoro).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B355 Class K stranded nickel-plated annealed copperASTM B355 Nickel Cu |
| 2 | Primary insulation | Extruded PTFE fluoropolymer primary insulationUL AWM Style 5196 |
| 3 | Fibreglass outer braid | Off-white PTFE-impregnated fibreglass outer braid (glass/fluoro)UL VW-1 Flame |
Single high-temperature conductor insulated in PTFE and protected by a varnished fibreglass outer braid.
Technical data
Sizes
| Conductor AWG | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×24 AWG | 1.9 | 102.68 | 2 | 11 | 15 |
| 1×22 AWG | 2.1 | 64.75 | 3 | 12 | 17 |
| 1×20 AWG | 2.3 | 40.00 | 5 | 14 | 18 |
| 1×18 AWG | 2.5 | 25.29 | 7 | 18 | 20 |
| 1×16 AWG | 2.9 | 16.02 | 12 | 28 | 23 |
| 1×14 AWG | 3.3 | 9.89 | 19 | 41 | 26 |
| 1×12 AWG | 3.8 | 6.22 | 30 | 62 | 30 |
| 1×10 AWG | 4.4 | 3.91 | 48 | 94 | 35 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2.5 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per ASTM B355 Nickel Cu at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -65 °C to +250 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | UL VW-1 Flame · Fibreglass Abrasion Armour | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.