Furnace, kiln & high-temp zone
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Product
SiFF 300/500 V Class 6 upgrades SiF with ultra-fine IEC 60228 Class 6 tinned copper stranding inside blue 180 °C halogen-free silicone rubber for tight bending, vibration, and thermal cycling in hot machinery.
Typical values for this cable type, based on DIN VDE 0250-502 · IEC 60228 Class 6 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.
Application fit
SiFF 300/500 V Class 6 upgrades SiF with ultra-fine IEC 60228 Class 6 tinned copper stranding inside blue 180 °C halogen-free silicone rubber for tight bending, vibration, and thermal cycling in hot machinery.
Thermal-rated 300/500 V SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.
Flexible 300/500 V SiR heat-resistant insulation terminates cleanly inside motor junction boxes, heaters, and hot windings.
Thermal-aged 300/500 V SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
High-dielectric 300/500 V SiR winding insulation handles compact submersible, traction, and industrial motor stator slots reliably.
300/500 V SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR300/500 V SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of SiFF 300/500V Class 6: IEC 60228 Class 6 flexible tinned annealed copper, Blue halogen-free 180 °C silicone rubber insulation, and Blue 180 °C halogen-free silicone rubber outer insulation.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 6 flexible tinned annealed copperIEC 60228 Class 6 |
| 2 | Extruded insulation | Blue halogen-free 180 °C silicone rubber insulationDIN VDE 0250-502 |
Single-conductor high-temperature wire with extruded Blue halogen-free 180 °C silicone rubber insulation.
Technical data
Sizes
| Conductor mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Metal index kg/km | Weight ≈ kg/km | Min. bend R 5×D mm |
|---|---|---|---|---|---|
| 1×0.5 mm² | 2.1 | 40.09 | 5 | 14 | 10.5 |
| 1×0.75 mm² | 2.4 | 26.73 | 7 | 17 | 12.0 |
| 1×1 mm² | 2.5 | 20.05 | 10 | 21 | 12.0 |
| 1×1.5 mm² | 2.8 | 13.67 | 14 | 26 | 14.0 |
| 1×2.5 mm² | 3.7 | 8.20 | 24 | 45 | 18.0 |
| 1×4 mm² | 4.3 | 5.09 | 38 | 69 | 22.0 |
| 1×6 mm² | 4.9 | 3.39 | 58 | 101 | 24.0 |
| 1×10 mm² | 6.2 | 1.96 | 96 | 166 | 31.0 |
| 1×16 mm² | 7.3 | 1.24 | 154 | 259 | 36.0 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric spark / withstand test | 2 kV AC without breakdown | Every manufactured drum |
| Conductor DC resistance check | Per IEC 60228 Class 6 at 20 °C | Every reel / drum length |
| Sample tests | ||
| Dimensional, wall thickness & thermal aging | Rated -60 °C to +180 °C continuous | Per production lot |
| Flame, chemical & mechanical qualification | Class 6 Extra-Flexible · 180 °C Continuous Silicone | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ