Contact

MIL-DTL-16878/6 Type ET 250 V Thin-Wall PTFE Wire200 °C 250 V ultra-thin 6-mil PTFE silver-plated copper hook-up wire

MIL-DTL-16878/6 Type ET (NEMA HP3) uses a compact 6-mil extruded PTFE dielectric over silver-plated copper conductors for lightweight, high-density 250 V aerospace modules and miniature sensors.

Flame-retardant
Oil-resistant
Approved
Order designation
MIL-DTL-16878/6 Type ET 1×26 AWG
Outer Ø
0.8 mm
Max. R20
150.00 Ω/km
Weight
9 kg/km
Min. bend R
4.0 mm
All sizes (7)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
250 V
Test voltage 1.5 kV AC
Temp. (fixed)
-65°C…+200°C
Flexing: -55 °C to +200 °C
Insulation
PTFE
6-mil thin-wall blue extruded PTFE
Min. bend radius
5 × OD
Fixed & equipment routing
Conductor
Silver-Plated Cu
Per MIL-DTL-16878/6 Type ET
Size range
1×32–1×20
7 standard configurations

Typical values for this cable type, based on MIL-DTL-16878/6 Type ET · NEMA HP3 · ASTM B298 Silver Cu — confirmed in the datasheet and quotation for your order.

Application fit

Is MIL-DTL-16878/6 Type ET right for your machine?

MIL-DTL-16878/6 Type ET (NEMA HP3) uses a compact 6-mil extruded PTFE dielectric over silver-plated copper conductors for lightweight, high-density 250 V aerospace modules and miniature sensors.

Switchgear & control cabinet wiring

Suitable

Compact 250 V PTFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 250 V PTFE insulation maintains dielectric safety across continuous high-temperature zones up to +200 °C.

Aerospace avionics bay & airframe loom

Suitable

Low-weight, high-temperature 250 V PTFE construction meets compact avionics racks, flight-control looms, and aerospace harnesses.

Precision test bench & clean equipment

Suitable

Clean, low-outgassing 250 V PTFE construction fits laboratory instruments, precision test benches, and controlled indoor enclosures.

Energy chain / drag chain

Not suitable

250 V PTFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

250 V PTFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesAerospace & AvionicsIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of MIL-DTL-16878/6 Type ET: ASTM B298 Class K stranded silver-plated annealed copper, 6-mil thin-wall blue extruded PTFE fluoropolymer insulation, and Blue 6-mil thin-wall extruded PTFE fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B298 Class K stranded silver-plated annealed copperASTM B298 Silver Cu
2Extruded insulation6-mil thin-wall blue extruded PTFE fluoropolymer insulationMIL-DTL-16878/6 Type ET

MIL-DTL-16878/6 Type ET Single-Core

Single-conductor high-temperature wire with extruded 6-mil thin-wall blue extruded PTFE fluoropolymer insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on MIL-DTL-16878/6 Type ET · NEMA HP3 · ASTM B298 Silver Cu. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
250 V
Test voltage
1.5 kV AC
Conductor
Silver-Plated Cu
Insulation
6-mil thin-wall blue extruded PTFE
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-65 °C to +200 °C
Temp. range (flexing)
-55 °C to +200 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
5 × OD (fixed)

Resistance

Flame / fire rating
Ultra-Thin 6-mil PTFE
Thermal / chemical
200 °C Continuous
Mechanical / special
Minimal Harness Weight
Outer finish
Blue 6-mil thin-wall extruded PTFE

Sizes

Single-Core High-Temp Hook-Up Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
5×D mm
1×32 AWG0.5600.00192.5
1×30 AWG0.6378.00193.0
1×28 AWG0.7238.00193.5
1×26 AWG0.8150.00194.0
1×24 AWG0.994.202114.5
1×22 AWG1.059.403125.0
1×20 AWG1.236.705146.0
  • Conductor DC resistance R20 at 20 °C per ASTM B298 Silver Cu.
  • Minimum bending radius calculated at 5 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test1.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B298 Silver Cu at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -65 °C to +200 °C continuousPer production lot
Flame, chemical & mechanical qualificationUltra-Thin 6-mil PTFE · 200 °C ContinuousType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

MIL-DTL-16878/6 Type ETNEMA HP3ASTM B298 Silver CuEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

MIL-DTL-16878/6 Type ET 250 V TEBAOFLEX.COM [MIL-DTL-16878/6 Type ET] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes MIL-DTL-16878/6 Type ET suited for 250 V and -65 °C to +200 °C operation?
MIL-DTL-16878/6 Type ET combines ASTM B298 Class K stranded silver-plated annealed copper with 6-mil thin-wall blue extruded PTFE fluoropolymer insulation and Blue 6-mil thin-wall extruded PTFE fluoropolymer outer insulation. 6-mil PTFE wall minimizes bundle diameter and weight inside compact airborne electronics enclosures.
What is the minimum bending radius of MIL-DTL-16878/6 Type ET during installation?
Maintain a minimum bending radius of 5 × OD across -55 °C to +200 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can MIL-DTL-16878/6 Type ET be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies MIL-DTL-16878/6 Type ET cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany MIL-DTL-16878/6 Type ET?
MIL-DTL-16878/6 Type ET conforms to MIL-DTL-16878/6 Type ET, NEMA HP3, ASTM B298 Silver Cu (Ultra-Thin 6-mil PTFE) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for MIL-DTL-16878/6 Type ET

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MIL-DTL-16878/6 Type ET 250 V Thin-Wall PTFE Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote