Contact

UL AWM 10475 15–40 kVDC High-Voltage Silicone WireUL 758 Style 10475 15–40 kVDC corona-resistant HV equipment lead wire

UL 10475 15–40 kVDC HV Wire pairs stranded tinned copper with heavy-wall white corona-resistant silicone/fluoropolymer insulation rated 15–40 kV DC and 150–200 °C for X-ray generators, lasers, and HV power supplies.

Flame-retardant
Oil-resistant
Approved
Order designation
UL 10475 15-40 kVDC HV Wire 1×18 AWG (30 kV DC)
Outer Ø
5.4 mm
Max. R20
23.20 Ω/km
Weight
46 kg/km
Min. bend R
54 mm
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
15–40 kV DC
Test voltage 50 kV DC
Temp. (fixed)
-60°C…+200°C
Flexing: -40 °C to +180 °C
Insulation
SiR
Heavy-wall white corona-resistant
Min. bend radius
10 × OD
Fixed & equipment routing
Conductor
Tinned Cu · Cl.K
Per UL AWM Style 10475
Size range
1×22–1×14
5 standard configurations

Typical values for this cable type, based on UL AWM Style 10475 · UL 758 · CSA AWM I A/B — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 10475 15-40 kVDC HV Wire right for your machine?

UL 10475 15–40 kVDC HV Wire pairs stranded tinned copper with heavy-wall white corona-resistant silicone/fluoropolymer insulation rated 15–40 kV DC and 150–200 °C for X-ray generators, lasers, and HV power supplies.

Switchgear & control cabinet wiring

Suitable

Compact 15–40 kV DC SiR profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Fixed installation

Suitable

Stable 15–40 kV DC SiR construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.

Precision test bench & clean equipment

Suitable

Clean, low-outgassing 15–40 kV DC SiR construction fits laboratory instruments, precision test benches, and controlled indoor enclosures.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 15–40 kV DC SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

15–40 kV DC SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

15–40 kV DC SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial oil/gas burners & steam boilersStationary CHP gas engines & cogenerationAutomotive, motorsport & heavy-duty ignitionX-ray, laser & high-voltage DC power supplies

Construction

Layer by layer

Representative construction of UL 10475 15-40 kVDC HV Wire: ASTM B172 / B33 Class K flexible tinned annealed copper, Heavy-wall white corona-resistant silicone rubber HV insulation, and White 15–40 kV DC corona-resistant silicone rubber outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 / B33 Class K flexible tinned annealed copperASTM B172 / B33
2Extruded insulationHeavy-wall white corona-resistant silicone rubber HV insulationUL AWM Style 10475

UL 10475 15-40 kVDC HV Wire Single-Core

Single-conductor high-temperature wire with extruded Heavy-wall white corona-resistant silicone rubber HV insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL AWM Style 10475 · UL 758 · CSA AWM I A/B. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
15–40 kV DC
Test voltage
50 kV DC
Conductor
Tinned Cu · Cl.K
Insulation
Heavy-wall white corona-resistant
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-60 °C to +200 °C
Temp. range (flexing)
-40 °C to +180 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
10 × OD (fixed)

Resistance

Flame / fire rating
Up to 40 kV DC Rated
Thermal / chemical
UL VW-1 Flame
Mechanical / special
Corona & Ozone Proof
Outer finish
White 15–40 kV DC corona-resistant

Sizes

15–40 kV DC High-Voltage Equipment Wire (AWG)
Conductor ·
DC Rating
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
10×D mm
1×22 AWG (15 kV DC)3.459.4031834
1×20 AWG (20 kV DC)4.236.7052842
1×18 AWG (30 kV DC)5.423.2084654
1×16 AWG (40 kV DC)6.814.70127268
1×14 AWG (40 kV DC)7.49.07199274
  • Conductor DC resistance R20 at 20 °C per ASTM B172 / B33.
  • Minimum bending radius calculated at 10 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test50 kV DC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B172 / B33 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -60 °C to +200 °C continuousPer production lot
Flame, chemical & mechanical qualificationUp to 40 kV DC Rated · UL VW-1 FlameType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL AWM Style 10475UL 758CSA AWM I A/BEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

UL 10475 15-40 kVDC HV Wire 15–40 kV DC TEBAOFLEX.COM [UL AWM Style 10475] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes UL 10475 15-40 kVDC HV Wire suited for 15–40 kV DC and -60 °C to +200 °C operation?
UL 10475 15-40 kVDC HV Wire combines ASTM B172 / B33 Class K flexible tinned annealed copper with Heavy-wall white corona-resistant silicone rubber HV insulation and White 15–40 kV DC corona-resistant silicone rubber outer insulation. Engineered for high-voltage DC medical X-ray, electrostatic precipitator, and semiconductor ion-implanter leads.
What is the minimum bending radius of UL 10475 15-40 kVDC HV Wire during installation?
Maintain a minimum bending radius of 10 × OD across -40 °C to +180 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can UL 10475 15-40 kVDC HV Wire be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies UL 10475 15-40 kVDC HV Wire cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany UL 10475 15-40 kVDC HV Wire?
UL 10475 15-40 kVDC HV Wire conforms to UL AWM Style 10475, UL 758, CSA AWM I A/B (Up to 40 kV DC Rated) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for UL 10475 15-40 kVDC HV Wire

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL AWM 10475 15–40 kVDC High-Voltage Silicone Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote