Contact

SAE AS22759/16 600 V 150 °C ETFE Aerospace WireTinned copper extruded ETFE 600 V lightweight airframe hook-up wire

SAE AS22759/16 combines stranded tinned copper with tough extruded ETFE fluoropolymer insulation rated 600 V and 150 °C for abrasion-prone commercial aircraft wire harnesses and instrumentation panels.

Flame-retardant
Oil-resistant
Approved
Order designation
SAE AS22759/16 1×18 AWG
Outer Ø
2.0 mm
Max. R20
23.20 Ω/km
Weight
17 kg/km
Min. bend R
12.0 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Test voltage 2.5 kV AC
Temp. (fixed)
-65°C…+150°C
Flexing: -55 °C to +150 °C
Insulation
ETFE
Extruded white ETFE fluoropolymer
Min. bend radius
6 × OD
Fixed & equipment routing
Conductor
Tinned Cu · Cl.K
Per SAE AS22759/16
Size range
1×24–1×10
8 standard configurations

Typical values for this cable type, based on SAE AS22759/16 · MIL-W-22759/16 · ASTM B33 Tinned Cu — confirmed in the datasheet and quotation for your order.

Application fit

Is SAE AS22759/16 right for your machine?

SAE AS22759/16 combines stranded tinned copper with tough extruded ETFE fluoropolymer insulation rated 600 V and 150 °C for abrasion-prone commercial aircraft wire harnesses and instrumentation panels.

Switchgear & control cabinet wiring

Suitable

Compact 600 V ETFE profile simplifies high-density routing inside control panels, avionics racks, and equipment chassis.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 600 V ETFE insulation maintains dielectric safety across continuous high-temperature zones up to +150 °C.

Aerospace avionics bay & airframe loom

Suitable

Low-weight, high-temperature 600 V ETFE construction meets compact avionics racks, flight-control looms, and aerospace harnesses.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 600 V ETFE geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Energy chain / drag chain

Not suitable

600 V ETFE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

600 V ETFE outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesAerospace & AvionicsIndustrial ovens, kilns & thermal processingAerospace avionics, defence & instrumentationSteelworks, glassworks & foundry equipmentSwitchgear cabinets, motors & heating appliances

Construction

Layer by layer

Representative construction of SAE AS22759/16: ASTM B172 / B33 Class K flexible tinned annealed copper, Extruded white ETFE fluoropolymer insulation, and White extruded ETFE fluoropolymer outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorASTM B172 / B33 Class K flexible tinned annealed copperASTM B172 / B33
2Extruded insulationExtruded white ETFE fluoropolymer insulationSAE AS22759/16

SAE AS22759/16 Single-Core

Single-conductor high-temperature wire with extruded Extruded white ETFE fluoropolymer insulation.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on SAE AS22759/16 · MIL-W-22759/16 · ASTM B33 Tinned Cu. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V
Test voltage
2.5 kV AC
Conductor
Tinned Cu · Cl.K
Insulation
Extruded white ETFE fluoropolymer insulation
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-65 °C to +150 °C
Temp. range (flexing)
-55 °C to +150 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
6 × OD (fixed)

Resistance

Flame / fire rating
150 °C Tough ETFE
Thermal / chemical
High Cut-Through Strength
Mechanical / special
FAR 25.869 Flame
Outer finish
White extruded ETFE fluoropolymer outer

Sizes

Single-Core High-Temp Hook-Up Wire (AWG)
Conductor
AWG
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
6×D mm
1×24 AWG1.494.202118.4
1×22 AWG1.659.403129.6
1×20 AWG1.836.7051410.8
1×18 AWG2.023.2071712.0
1×16 AWG2.414.70122514.0
1×14 AWG2.89.07193717.0
1×12 AWG3.35.71305720.0
1×10 AWG3.93.59488923.0
  • Conductor DC resistance R20 at 20 °C per ASTM B172 / B33.
  • Minimum bending radius calculated at 6 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test2.5 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer ASTM B172 / B33 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -65 °C to +150 °C continuousPer production lot
Flame, chemical & mechanical qualification150 °C Tough ETFE · High Cut-Through StrengthType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SAE AS22759/16MIL-W-22759/16ASTM B33 Tinned CuEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

SAE AS22759/16 600 V TEBAOFLEX.COM [SAE AS22759/16] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
305 m (1,000 ft) · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes SAE AS22759/16 suited for 600 V and -65 °C to +150 °C operation?
SAE AS22759/16 combines ASTM B172 / B33 Class K flexible tinned annealed copper with Extruded white ETFE fluoropolymer insulation and White extruded ETFE fluoropolymer outer insulation. ETFE delivers superior cut-through and cold-flow resistance versus PTFE at lighter airframe weight.
What is the minimum bending radius of SAE AS22759/16 during installation?
Maintain a minimum bending radius of 6 × OD across -55 °C to +150 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can SAE AS22759/16 be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies SAE AS22759/16 cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany SAE AS22759/16?
SAE AS22759/16 conforms to SAE AS22759/16, MIL-W-22759/16, ASTM B33 Tinned Cu (150 °C Tough ETFE) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for SAE AS22759/16

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SAE AS22759/16 600 V 150 °C ETFE Aerospace Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote