TT-2800 RTD 600 V 530 °C Mica-Glass Screened RTD CableIEC 60751 / UL 5128 · 600 V · -60 °C to +530 °C 3×18 AWG nickel-plated copper RTD sensor cable

TT-2800 RTD 600 V +530 °C three-wire RTD sensor cable featuring 3 × 18 AWG 2% nickel-plated copper conductors, mica tape plus color-coded fiberglass core insulation, NPC braid screen with drain wire, PTFE barrier tape and a woven fiberglass jacket.

EMC screen
Low-EMC design
Flame-retardant
Approved
Order designation
TT-2800 RTD 3×18 AWG Screened
Outer Ø ≈
7.4 mm
Weight ≈
86 kg/km
Tensile load ≈
0.6 kN
Core / stranding
19/30 AWG 2% NPC + NPC braid
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
3-wire Pt100 / Pt1000 RTD sensor
Operating temp.
−60…+530 °C
Continuous thermal operating range
Min. bend radius
8 × OD
Installed / dynamic routing limit
Core / conductor
3×18 AWG NPC
2% nickel-plated copper + drain
Outer protection
Fiberglass Braid
Woven glass + PTFE tape + NPC braid
Standard
IEC 60751
IEC 60751 / UL AWM 5128

Typical values for this cable type, based on IEC 60751 / UL AWM 5128 — confirmed in the datasheet and quotation for your order.

Application fit

Is TT-2800 RTD right for your machine?

TT-2800 RTD 600 V +530 °C three-wire RTD sensor cable featuring 3 × 18 AWG 2% nickel-plated copper conductors, mica tape plus color-coded fiberglass core insulation, NPC braid screen with drain wire, PTFE barrier tape and a woven fiberglass jacket.

Furnace, kiln & high-temp zone

Suitable

Composite mica-tape, PTFE barrier and heavy fiberglass braid operate continuously at conductor temperatures up to +530 °C.

Switchgear & control cabinet wiring

Suitable

Red/Red/White IEC/ANSI 3-wire RTD color coding and 85% NPC braid screen preserve millivolt Pt100 accuracy.

Fixed installation

Suitable

Skived PTFE fluoropolymer barrier over the screen blocks hot oil mist and moisture ingress.

Immersion & wet locations

Not suitable

Woven fiberglass outer jacket is designed for dry radiant heat and furnace zones, not permanent water submersion.

HFPS-3020-19
Typical machinesOil & Gas CableSteelworks Blast Furnaces, Coke Ovens & Continuous CastersGlass Melting Furnaces, Ceramic Kilns & Heat-Treat OvensPetrochemical Reformers, Boilers & Exhaust Gas DuctsAluminium Smelting Cells & Foundry Temperature Loops

Construction

Layer by layer

Shown: TT-2800 RTD (IEC 60751 / UL AWM 5128) featuring rtd conductors (3x18 awg), composite core insulation and braided outer jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1RTD Conductors (3x18 AWG)Three 18 AWG (0.82 mm²) finely stranded 2% nickel-plated copper conductors engineered for 530 °C (986 °F) three-wire RTD bridge compensationIEC 60751 / UL AWM 5128
2Composite Core InsulationLapped phlogopite mica dielectric tapes covered with color-coded woven fiberglass braid (Red / Red / White per IEC/ANSI RTD coding)IEC 60751 / UL AWM 5128
3Drain Wire & Overall ShieldStranded nickel-plated copper drain wire in continuous contact with an 85% coverage nickel-plated copper (NPC) overall braid shieldIEC 60751 / UL AWM 5128
4Dielectric Barrier TapeHelically wrapped skived polytetrafluoroethylene (PTFE) fluoropolymer barrier tape sealing the shield against moisture and furnace dustIEC 60751 / UL AWM 5128
5Braided Outer JacketHeavy-duty high-temperature treated woven fiberglass outer braid jacket resistant to radiant heat, molten splash, and abrasionIEC 60751 / UL AWM 5128

TT-2800 RTD — Standard Execution

Built to IEC 60751 / UL AWM 5128 with rtd conductors (3x18 awg) and braided outer jacket

TT-2800 RTD — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

TT-2800 RTD — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60751 / UL AWM 5128. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (IEC 60751 / UL AWM 5128)
Core / conductor construction
RTD Conductors (3x18 AWG) — Three 18 AWG (0.82 mm²) finely stranded 2% nickel-plated copper conductors engineered for 530 °C (986 °F) three-wire RTD bridge compensation
Primary dielectric / insulation
Composite Core Insulation — Lapped phlogopite mica dielectric tapes covered with color-coded woven fiberglass braid (Red / Red / White per IEC/ANSI RTD coding)

Thermal

Continuous operating temperature
−60…+530 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
Braided Outer Jacket — Heavy-duty high-temperature treated woven fiberglass outer braid jacket resistant to radiant heat, molten splash, and abrasion
Minimum bending radius
8 × OD
Structural layer count
5 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per IEC 60751 / UL AWM 5128
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60751 / UL AWM 5128
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TT-2800 RTD
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

4 standard TT-2800 RTD configurations

Manufactured to IEC 60751 / UL AWM 5128 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
TT-2800 RTD Construction Schedule (−60…+530 °C)
TT-2800 RTD 3×20 AWG Screened3 × 20 AWG (0.56 mm²) RTD19/32 AWG 2% NPC + NPC braid6.4620.452
TT-2800 RTD 3×18 AWG Screened3 × 18 AWG (0.89 mm²) RTD19/30 AWG 2% NPC + NPC braid7.4860.660
TT-2800 RTD 4×18 AWG Screened4 × 18 AWG (0.89 mm²) RTD19/30 AWG 2% NPC + NPC braid8.21080.866
TT-2800 RTD 3×16 AWG Screened3 × 16 AWG (1.34 mm²) RTD26/30 AWG 2% NPC + NPC braid8.61180.970
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per IEC 60751 / UL AWM 5128.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (IEC 60751 / UL AWM 5128)Electrical parameters and outer diameter within IEC 60751 / UL AWM 5128 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (IEC 60751 / UL AWM 5128)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (IEC 60751 / UL AWM 5128)Verified structural and dielectric integrity across −60…+530 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60751 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TT-2800 RTD IEC 60751 600 V CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is TT-2800 RTD engineered for?
TT-2800 RTD 600 V +530 °C three-wire RTD sensor cable featuring 3 × 18 AWG 2% nickel-plated copper conductors, mica tape plus color-coded fiberglass core insulation, NPC braid screen with drain wire, PTFE barrier tape and a woven fiberglass jacket. It is built to IEC 60751 / UL AWM 5128 for steelworks blast furnaces, coke ovens & continuous casters and glass melting furnaces, ceramic kilns & heat-treat ovens.
What are the minimum bending radius and operating temperature range for TT-2800 RTD?
The minimum bending radius for TT-2800 RTD is 8 × OD across its continuous operating temperature range of -60 °C to +530 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of TT-2800 RTD arranged from inside to outside?
From inside to outside, the construction sequence is: (01) RTD Conductors (3x18 AWG) (Three 18 AWG (0.82 mm²) finely stranded 2% nickel-plated copper conductors engineered for 530 °C (986 °F) three-wire RTD bridge compensation); (02) Composite Core Insulation (Lapped phlogopite mica dielectric tapes covered with color-coded woven fiberglass braid (Red / Red / White per IEC/ANSI RTD coding)); (03) Drain Wire & Overall Shield (Stranded nickel-plated copper drain wire in continuous contact with an 85% coverage nickel-plated copper (NPC) overall braid shield); (04) Dielectric Barrier Tape (Helically wrapped skived polytetrafluoroethylene (PTFE) fluoropolymer barrier tape sealing the shield against moisture and furnace dust); (05) Braided Outer Jacket (Heavy-duty high-temperature treated woven fiberglass outer braid jacket resistant to radiant heat, molten splash, and abrasion).
What factory test certificates are supplied with TT-2800 RTD?
Every production drum of TT-2800 RTD undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per IEC 60751 / UL AWM 5128, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TT-2800 RTD

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TT-2800 RTD 600 V 530 °C Mica-Glass Screened RTD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote