Furnace, kiln & high-temp zone
ISO 3808 Class F silicone sheath and EPDM/VMQ dielectric operate continuously from -50 °C to +220 °C (+250 °C peak).
Product
Inductive wire-wound EMI/RFI suppression HV ignition cable with an aramid/glass cord, magnetic ferrite core, helical CuNi44/SS304L resistance wire (0.5–5.6 kΩ/m), E-glass braid, and a +220 °C (+250 °C peak) silicone jacket (7, 8, 8.5 mm OD).
Typical values for this cable type, based on ISO 3808 Class F / SAE J2031 Type 3 Inductive EMI Suppression Ignition Cable — confirmed in the datasheet and quotation for your order.
Application fit
Select Wire-Wound Suppression Ignition Cable when high-energy spark ignition systems run near PLC controllers, engine ECUs, CAN-bus networks, or flame sensors that would be disrupted by broadband spark RFI.
ISO 3808 Class F silicone sheath and EPDM/VMQ dielectric operate continuously from -50 °C to +220 °C (+250 °C peak).
Helical alloy wire over a ferromagnetic ferrite core forms a distributed inductor that chokes MHz spark ringing.
Aramid/glass tensile core and E-glass reinforcement braid provide ≥ 250 N pull-off strength for spark plug and igniter boot assembly.
Designed for fixed and engine-mounted high-voltage ignition harnesses, not power reeling drums.
Use NSHTÖU for drum reelingConstruction
6-layer ISO 3808 Class F inductive suppression construction: aramid/glass core, magnetic ferrite layer, helical CuNi44/SS304L winding, HV dielectric, glass braid, and VMQ jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Aramid/glass core + ferrite + helical wire | High-tensile aramid/E-glass centre cord coated with ferromagnetic ferrite elastomer and helically wound with CuNi44 or SS304L wire (40–100 turns/cm)Acts as a distributed inductive choke (0.5 to 5.6 kΩ/m) that suppresses 30–1000 MHz spark EMI without burning out like carbon cores |
| 2 | Conductive stress-control coating | Semi-conductive elastomer encapsulation over the helical resistance windingEqualises radial electric field stress across the microscopic wire turns to prevent internal corona |
| 3 | High-voltage EPDM / VMQ inner dielectric | Extruded high-dielectric-strength EPDM or methyl-vinyl silicone rubber (VMQ) primary insulationWithstands 25 kV to 40 kV DC ignition pulses and 35–45 kV breakdown tests |
| 4 | Fibreglass mechanical reinforcement braid | Open-weave high-tenacity E-glass yarn reinforcement between inner dielectric and outer jacketBonds the inner and outer layers together and prevents jacket stripping failure during boot removal |
| 5 | ISO 3808 Class F silicone outer sheath | Oil-, fuel-, ozone-, and heat-resistant VMQ silicone rubber outer jacket (7.0 mm, 8.0 mm, or 8.5 mm OD)Seals tightly into SAE/DIN spark boots and operates from -50 °C to +220 °C (+250 °C peak) |
Standard 7.0 mm OD inductive suppression cable for industrial gas engines, CHP gensets, and burners
Low-resistance 500–1500 Ω/m heavy-wall 8.0/8.5 mm cable for high-compression biogas engines and CD igniters
Technical data
Sizes
Engineering dimensions, conductor stranding, mass and electrical ratings for Wire-Wound Suppression Ignition Cable per ISO 3808 Class F / SAE J2031 Type 3 Inductive EMI Suppression Ignition Cable.
| Order designation | Cross-section / size | Conductor build | Wall ≈ mm | Outer Ø ≈ mm | Metal kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| Standard Wire-Wound Suppression Ignition Cable configurations | ||||||||
| WWSI-7.0-5K6 (7 mm · 5.6 kΩ/m) | Ø 7.0 mm (5.6 kΩ/m) | CuNi44 on ferrite core | 2.55 | 7.00 | 12.0 | 58.0 | 42 | |
| WWSI-7.0-2K2 (7 mm · 2.2 kΩ/m) | Ø 7.0 mm (2.2 kΩ/m) | CuNi44 on ferrite core | 2.55 | 7.00 | 13.0 | 59.0 | 42 | |
| WWSI-7.0-1K0 (7 mm · 1.0 kΩ/m) | Ø 7.0 mm (1.0 kΩ/m) | CuNi44 on ferrite core | 2.50 | 7.00 | 14.0 | 60.0 | 42 | |
| WWSI-7.0-500R (7 mm · 500 Ω/m) | Ø 7.0 mm (500 Ω/m) | CuNi44 on ferrite core | 2.50 | 7.00 | 15.0 | 61.0 | 42 | |
| WWSI-8.0-5K6 (8 mm · 5.6 kΩ/m) | Ø 8.0 mm (5.6 kΩ/m) | CuNi44 on ferrite core | 3.00 | 8.00 | 14.0 | 74.0 | 48 | |
| WWSI-8.0-2K2 (8 mm · 2.2 kΩ/m) | Ø 8.0 mm (2.2 kΩ/m) | CuNi44 on ferrite core | 3.00 | 8.00 | 15.0 | 75.0 | 48 | |
| WWSI-8.0-1K5 (8 mm · 1.5 kΩ/m) | Ø 8.0 mm (1.5 kΩ/m) | CuNi44 on ferrite core | 2.95 | 8.00 | 16.0 | 76.0 | 48 | |
| WWSI-8.0-500R (8 mm · 500 Ω/m) | Ø 8.0 mm (500 Ω/m) | CuNi44 on ferrite core | 2.95 | 8.00 | 17.0 | 77.0 | 48 | |
| WWSI-8.5-500R (8.5 mm · 500 Ω/m) | Ø 8.5 mm (500 Ω/m) | CuNi44 on ferrite core | 3.15 | 8.50 | 18.0 | 86.0 | 51 | |
| Configuration | Max. DC R @ 20 °C Ω/km | Primary rating (A or kV) | Derated / AC rating | Dielectric test V AC rms |
|---|---|---|---|---|
| WWSI-7.0-5K6 (7 mm · 5.6 kΩ/m) (Ø 7.0 mm (5.6 kΩ/m)) | 5,600.00 | 30.0 | 14.0 | 35,000 |
| WWSI-7.0-2K2 (7 mm · 2.2 kΩ/m) (Ø 7.0 mm (2.2 kΩ/m)) | 2,200.00 | 30.0 | 14.0 | 35,000 |
| WWSI-7.0-1K0 (7 mm · 1.0 kΩ/m) (Ø 7.0 mm (1.0 kΩ/m)) | 1,000.00 | 30.0 | 14.0 | 35,000 |
| WWSI-7.0-500R (7 mm · 500 Ω/m) (Ø 7.0 mm (500 Ω/m)) | 500.00 | 30.0 | 14.0 | 35,000 |
| WWSI-8.0-5K6 (8 mm · 5.6 kΩ/m) (Ø 8.0 mm (5.6 kΩ/m)) | 5,600.00 | 35.0 | 16.0 | 40,000 |
| WWSI-8.0-2K2 (8 mm · 2.2 kΩ/m) (Ø 8.0 mm (2.2 kΩ/m)) | 2,200.00 | 35.0 | 16.0 | 40,000 |
| WWSI-8.0-1K5 (8 mm · 1.5 kΩ/m) (Ø 8.0 mm (1.5 kΩ/m)) | 1,500.00 | 35.0 | 16.0 | 40,000 |
| WWSI-8.0-500R (8 mm · 500 Ω/m) (Ø 8.0 mm (500 Ω/m)) | 500.00 | 35.0 | 16.0 | 40,000 |
| WWSI-8.5-500R (8.5 mm · 500 Ω/m) (Ø 8.5 mm (500 Ω/m)) | 500.00 | 40.0 | 18.0 | 45,000 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Dielectric spark / high-voltage withstand test | 100 % in-line spark and AC/DC dielectric withstand per ISO 3808 Class F / SAE J2031 Type 3 Inductive EMI Suppression Ignition Cable | Every manufactured length |
| Conductor DC resistance & continuity check | Within maximum 20 °C resistance limit specified for Wire-Wound Suppression Ignition Cable | Every spool or drum length |
| Sample tests | ||
| Thermal ageing & dimensional verification | Wall thickness, concentricity and post-ageing elongation per ISO 3808 Class F / SAE J2031 Type 3 Inductive EMI Suppression Ignition Cable | Per production batch |
| Flame, outgassing or high-temperature endurance | Qualified to ISO 3808 Class F / SAE J2031 Type 3 Inductive EMI Suppression Ignition Cable thermal and environmental performance criteria | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.