FZLSi 10/12 kV 180 °C Silicone Burner Ignition CableDIN-style 10/12 kV flexible tinned copper silicone boiler ignition cable

FZLSi 10/12 kV Ignition uses IEC 60228 Class 5 flexible tinned copper inside heavy-wall red-oxide 180 °C halogen-free silicone rubber rated up to 12 kV peak for industrial oil/gas burners, boilers, and furnaces.

Flame-retardant
Oil-resistant
Approved
Order designation
FZLSi 10/12 kV Ignition 1×1.5 mm² (12 kV)
Outer Ø
6.4 mm
Max. R20
13.67 Ω/km
Weight
67 kg/km
Min. bend R
51 mm
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
10/12 kV
Test voltage 25 kV AC
Temp. (fixed)
-60°C…+180°C
Flexing: -25 °C to +180 °C
Insulation
SiR
Heavy-wall red-oxide 180 °C
Min. bend radius
8 × OD
Fixed & equipment routing
Conductor
Tinned Cu · Cl.5
Per DIN VDE 0250 (ref.)
Size range
1×1.0–1×4.0
4 standard configurations

Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 5 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.

Application fit

Is FZLSi 10/12 kV Ignition right for your machine?

FZLSi 10/12 kV Ignition uses IEC 60228 Class 5 flexible tinned copper inside heavy-wall red-oxide 180 °C halogen-free silicone rubber rated up to 12 kV peak for industrial oil/gas burners, boilers, and furnaces.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 10/12 kV SiR insulation maintains dielectric safety across continuous high-temperature zones up to +180 °C.

Fixed installation

Suitable

Stable 10/12 kV SiR construction routes cleanly in stationary conduits, raceways, ducts, and equipment bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 10/12 kV SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Control cabinet & internal panel wiring

Suitable

Compact flame-retardant 10/12 kV SiR geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.

Energy chain / drag chain

Not suitable

10/12 kV SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

10/12 kV SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesIndustrial oil/gas burners & steam boilersStationary CHP gas engines & cogenerationAutomotive, motorsport & heavy-duty ignitionX-ray, laser & high-voltage DC power supplies

Construction

Layer by layer

Representative construction of FZLSi 10/12 kV Ignition: IEC 60228 Class 5 flexible tinned annealed copper, Heavy-wall red-oxide 180 °C corona-resistant silicone rubber, and Red-oxide heavy-wall 180 °C halogen-free silicone rubber outer insulation.

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 5 flexible tinned annealed copperIEC 60228 Class 5
2Extruded insulationHeavy-wall red-oxide 180 °C corona-resistant silicone rubberDIN VDE 0250 (ref.)

FZLSi 10/12 kV Ignition Single-Core

Single-conductor high-temperature wire with extruded Heavy-wall red-oxide 180 °C corona-resistant silicone rubber.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 5 · IEC 60754-1 Halogen-Free. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
10/12 kV
Test voltage
25 kV AC
Conductor
Tinned Cu · Cl.5
Insulation
Heavy-wall red-oxide 180 °C
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-60 °C to +180 °C
Temp. range (flexing)
-25 °C to +180 °C
Peak / short-circuit
+220 °C (short-term)
Min. bending radius
8 × OD (fixed)

Resistance

Flame / fire rating
12 kV Peak Burner Ignition
Thermal / chemical
180 °C Continuous Silicone
Mechanical / special
Ozone & Corona Resistant
Outer finish
Red-oxide heavy-wall 180 °C halogen-free

Sizes

10/12 kV Silicone Burner Ignition (mm²)
Conductor ·
Voltage
Outer Ø ≈
mm
Max. R20
Ω/km
Metal index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×1.0 mm² (10 kV)5.620.05105145
1×1.5 mm² (12 kV)6.413.67146751
1×2.5 mm² (12 kV)7.28.20249458
1×4.0 mm² (15 kV)8.45.093813667
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 5.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom core counts and lengths available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric spark / withstand test25 kV AC without breakdownEvery manufactured drum
Conductor DC resistance checkPer IEC 60228 Class 5 at 20 °CEvery reel / drum length
Sample tests
Dimensional, wall thickness & thermal agingRated -60 °C to +180 °C continuousPer production lot
Flame, chemical & mechanical qualification12 kV Peak Burner Ignition · 180 °C Continuous SiliconeType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250 (ref.)IEC 60228 Class 5IEC 60754-1 Halogen-FreeEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

FZLSi 10/12 kV Ignition 10/12 kV TEBAOFLEX.COM [DIN VDE 0250 (ref.)] [Size] [Metre mark]
Delivery form
Spools, coils or wooden export reels
Standard lengths
100 m · 500 m · 1,000 m
MOQ
100 m (stock sizes) · 500 m (production)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-22
Updated
2026-11-22

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes FZLSi 10/12 kV Ignition suited for 10/12 kV and -60 °C to +180 °C operation?
FZLSi 10/12 kV Ignition combines IEC 60228 Class 5 flexible tinned annealed copper with Heavy-wall red-oxide 180 °C corona-resistant silicone rubber and Red-oxide heavy-wall 180 °C halogen-free silicone rubber outer insulation. Heavy-wall corona-resistant silicone feeds high-voltage spark electrodes on industrial boilers and gas turbines.
What is the minimum bending radius of FZLSi 10/12 kV Ignition during installation?
Maintain a minimum bending radius of 8 × OD across -25 °C to +180 °C flexing temperatures to protect conductor stranding and dielectric integrity.
Can FZLSi 10/12 kV Ignition be supplied in custom lengths, colours, or core configurations?
Yes. TEBAOFLEX supplies FZLSi 10/12 kV Ignition cut-to-length or on export reels with optional colour coding, jacket printing, and factory pre-termination.
What standards and quality certificates accompany FZLSi 10/12 kV Ignition?
FZLSi 10/12 kV Ignition conforms to DIN VDE 0250 (ref.), IEC 60228 Class 5, IEC 60754-1 Halogen-Free (12 kV Peak Burner Ignition) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for FZLSi 10/12 kV Ignition

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FZLSi 10/12 kV 180 °C Silicone Burner Ignition Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote