Contact

High Temperature Cable

Cables for elevated ambient and radiant heat service conditions.

How does the cable move?

Pick one or more duties — the list below updates.

119 high temperature cable

Voltage
Standard
Sheath
Features

Heating cables

Self-regulating, constant-wattage and mineral-insulated heating cables for pipes and vessels.

12 cables
ELSR-SH 250°C Heating Cable cross-section showing core geometry and red outer profile
ELSR-SH 250 °C Self-Regulating Process Heating CableELSR-SH 250 °C Self-Regulating Process Heating Cable
230 V
Fixed, furnace & kiln
IECFluoropolymer
230 V, IEC, Fluoropolymer sheathFixed, furnace & kiln
Ni80Cr20 (Cr20Ni80) — cable cross-section
Ni80Cr20 (Cr20Ni80)Ni80Cr20 Nickel-Chromium Austenitic Resistance Heating Alloy Wire
Up to 690 V AC
Fixed, furnace & kiln
DIN VDEOther
Up to 690 V AC, DIN VDE, Other sheathFixed, furnace & kiln
HSB High-Temperature Self-Regulating Heating Cable
HSBHSB High-Temperature Self-Regulating Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
ELSR-N / ELSR-M / ELSR-H Self-Regulating Heating Cable
ELSR-N / ELSR-M / ELSR-HELSR-N / ELSR-M / ELSR-H Self-Regulating Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
SECT Long-Line Skin-Effect Pipeline Heating Cable
SECTSECT Long-Line Skin-Effect Pipeline Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designOther
—, TEBAOFLEX design, Other sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
BTV 65 °C Pipe Freeze-Protection Heating Cable
BTVBTV 65 °C Pipe Freeze-Protection Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
HAX Alloy 825 Mineral-Insulated Heating Cable
HAXHAX Alloy 825 Mineral-Insulated Heating Cable
300 V · 600 V
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designOther
300 V · 600 V, TEBAOFLEX design, Other sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
HIQ1M / HIQ2M Alloy 600 Mineral-Insulated Heating Cable
HIQ1M / HIQ2MHIQ1M / HIQ2M Alloy 600 Mineral-Insulated Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designOther
—, TEBAOFLEX design, Other sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
HSQ1M Stainless-Steel Mineral-Insulated Heating Cable
HSQ1MHSQ1M Stainless-Steel Mineral-Insulated Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designOther
—, TEBAOFLEX design, Other sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
QTVR 110 °C Process Maintenance Heating Cable
QTVRQTVR 110 °C Process Maintenance Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
XTV 121 °C Industrial Process Heating Cable
XTVXTV 121 °C Industrial Process Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
KTV 150 °C High-Temperature Process Heating Cable
KTVKTV 150 °C High-Temperature Process Heating Cable
—
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
TEBAOFLEX designFluoropolymer
—, TEBAOFLEX design, Fluoropolymer sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)

Fire-resistant & fire alarm cables

Circuit-integrity and fire-alarm cables that keep emergency circuits working in a fire.

2 cables
LIHH FE180 300 V cross-section showing core geometry and orange outer profile
LIHH FE180 300 VLIHH FE180 300 V Fire-Resistant Halogen-Free Signal Cable
300 V
Fixed, furnace & kiln
DIN VDEHalogen-free
300 V, DIN VDE, Halogen-free sheathFixed, furnace & kiln
SIMH FE180 / PH120 cross-section showing core geometry and orange outer profile
SIMH FE180 / PH120SIMH FE180 / PH120 0.6/1 kV Fire-Resistant Power Cable
0.6/1 kV
Fixed, furnace & kiln
DIN VDEHalogen-free
0.6/1 kV, DIN VDE, Halogen-free sheathFixed, furnace & kiln

Instrumentation cables

Pair- and triad-screened cables for measurement and instrument circuits.

11 cables
1-FT-288-12/18 Wireline cross-section showing core geometry and grey outer profile
1-FT-288-12/18 Wireline1-FT-288-12/18 High-Temp Armored Wireline Cable
1000 V
Free-hanging, drilling rig
IEEE 1580Fluoropolymer
1000 V, IEEE 1580, Fluoropolymer sheathFree-hanging, drilling rig
1-FT-295-ETFJ Wireline cross-section showing core geometry and blue outer profile
1-FT-295-ETFJ Wireline1-FT-295-ETFJ Blue ETFE-Jacketed Wireline Cable
1000 V
Free-hanging, drilling rig
IEEE 1580Fluoropolymer
1000 V, IEEE 1580, Fluoropolymer sheathFree-hanging, drilling rig
1-FT-322-12/18-77 Wireline cross-section showing core geometry and grey outer profile
1-FT-322-12/18-77 Wireline1-FT-322-12/18-77 260 °C Armored Wireline Cable
1000 V
Free-hanging, drilling rig
IEEE 1580Fluoropolymer
1000 V, IEEE 1580, Fluoropolymer sheathFree-hanging, drilling rig
1-PFA-322 550°F Wireline cross-section showing core geometry and grey outer profile
1-PFA-322 550°F Wireline1-PFA-322 550 °F (288 °C) PFA Armored Wireline Cable
1000 V
Free-hanging, drilling rig
IEEE 1580Fluoropolymer
1000 V, IEEE 1580, Fluoropolymer sheathFree-hanging, drilling rig
ANSI Type K FEP Cable cross-section showing core geometry and brown outer profile
ANSI Type K Duplex FEP 200 °C Thermocouple CableANSI Type K Duplex FEP 200 °C Thermocouple Cable
300 V
Fixed, furnace & kiln
IECFluoropolymer
300 V, IEC, Fluoropolymer sheathFixed, furnace & kiln
ANSI Type K PFA Cable cross-section showing core geometry and grey outer profile
ANSI Type K Duplex PFA 260 °C Thermocouple CableANSI Type K Duplex PFA 260 °C Thermocouple Cable
300 V
Fixed, furnace & kiln
IECFluoropolymer
300 V, IEC, Fluoropolymer sheathFixed, furnace & kiln
ANSI Type K PTFE Cable cross-section showing core geometry and brown outer profile
ANSI Type K Fused-PTFE Tape 260 °C Thermocouple CableANSI Type K Fused-PTFE Tape 260 °C Thermocouple Cable
300 V
Fixed, furnace & kiln
IECFluoropolymer
300 V, IEC, Fluoropolymer sheathFixed, furnace & kiln
FEP/C/FEP 4×0.22 RTD cross-section showing core geometry and white outer profile
FEP/C/FEP 4×0.22 RTDFEP/C/FEP 4×0.22 mm² 200 °C Pt100 RTD Sensor Cable
300 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
300 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
FEP/C/FEP Multi-Pair KX cross-section showing core geometry and green outer profile
FEP/C/FEP Multi-Pair KXFEP/C/FEP Multi-Pair KX 200 °C Thermocouple Cable
300 V
Fixed, furnace & kiln
DIN VDEFluoropolymer
300 V, DIN VDE, Fluoropolymer sheathFixed, furnace & kiln
ACIC THERMOCOUPLE JX — cable cross-section
ACIC THERMOCOUPLE JXACIC Type JX Interlocked Aluminum Armored Thermocouple Extension
300 V
Fixed
UL / CSAPVC
300 V, UL / CSA, PVC sheathFixed
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) — cable cross-section
Type JX Thermocouple Extension + 5G1.5 Control Composite CableType JX Thermocouple Extension + 5G1.5 Control Composite Cable
300/500 V
Fixed, furnace & kiln
IECPVC
300/500 V, IEC, PVC sheathFixed, furnace & kiln

Industrial data & RF cables

PROFINET, PROFIBUS, CAN bus, RS-485 and coaxial cables for industrial networks.

4 cables
FP/FA 260°C Impedance Pair cross-section showing core geometry and white outer profile
FP/FA 260°C Impedance PairFP/FA 260 °C 100 Ω Controlled-Impedance PTFE/PFA Pair
300 V
Fixed, control cabinet
UL / CSAFluoropolymer
300 V, UL / CSA, Fluoropolymer sheathFixed, control cabinet
LL142 50Ω ePTFE Coax cross-section showing core geometry and blue outer profile
LL142 50 Ω Low-Loss Expanded-PTFE Microwave CoaxLL142 50 Ω Low-Loss Expanded-PTFE Microwave Coax
500 V
Fixed, control cabinet
IECFluoropolymer
500 V, IEC, Fluoropolymer sheathFixed, control cabinet
M17/176-00002 PFA Twinax cross-section showing core geometry and blue outer profile
M17/176-00002 PFA TwinaxMIL-DTL-17 M17/176-00002 77 Ω PFA Twinax Data Cable
300 V
Fixed, control cabinet
Fluoropolymer
300 V, , Fluoropolymer sheathFixed, control cabinet
M17/93-00001 PFA Coax 250°C cross-section showing core geometry and grey outer profile
MIL-DTL-17 M17/93-00001 50 Ω 250 °C PFA Coax CableMIL-DTL-17 M17/93-00001 50 Ω 250 °C PFA Coax Cable
750 V
Fixed, control cabinet
Fluoropolymer
750 V, , Fluoropolymer sheathFixed, control cabinet

Overhead conductors

Bare ACSR, AAAC and HTLS composite-core lines, XLPE aerial bundled cables and railway contact wires.

5 cables
ACSS — cable cross-section
ACSSACSS High-Temperature Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ACCC /TW — cable cross-section
ACCC /TWCarbon-Composite Core Trapezoidal Aluminum Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ACCR — cable cross-section
ACCRAluminum Conductor Composite Reinforced Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
GZTACSR — cable cross-section
GZTACSRGZTACSR Gap-Type Super-Thermal Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ZTACIR-AS — cable cross-section
ZTACIR-ASZTACIR / TACIR Super-Thermal Invar-Core Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed

Magnet & winding wires

Enamelled copper and aluminum magnet wires, paper-wrapped transformer conductors and hollow water-cooled profiles.

5 cables
MW 35-A / IEC 60317-25 EAIW-AL 200 — cable cross-section
MW 35-A / IEC 60317-25 EAIW-AL 200Class 200 Polyesterimide + PAI Overcoat Enamelled Aluminum Magnet Wire
1–1 kV
Motor & traction leads, VFD motor feeder
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, VFD motor feeder
CTC-AR Aramid-Paper Covered Wire — cable cross-section
Aramid Paper-Wrapped Round Copper Winding WireAramid Paper-Wrapped Round Copper Winding Wire
1–35 kV
Fixed, motor & traction leads
IECOther
1–35 kV, IEC, Other sheathFixed, motor & traction leads
POLYESTER-GLASS ENAMEL WIRE — cable cross-section
IEC 60317-48 Class 200 Polyester-Glass Yarn Covered WireIEC 60317-48 Class 200 Polyester-Glass Yarn Covered Wire
1–3.6 kV
Furnace & kiln, motor & traction leads
IECGlass braid
1–3.6 kV, IEC, Glass braid sheathFurnace & kiln, motor & traction leads
POLYIMIDE-FEP FLAT WIRE — cable cross-section
Class 240 Polyimide-FEP Film-Tape Wrapped Rectangular Copper WireClass 240 Polyimide-FEP Film-Tape Wrapped Rectangular Copper Wire
1–6 kV
Submerged, motor & traction leads
IECFluoropolymer
1–6 kV, IEC, Fluoropolymer sheathSubmerged, motor & traction leads
OFC-HC Hollow Water-Cooled Conductor — cable cross-section
Oxygen-Free Copper Hollow Water-Cooled Magnet Conductor ProfileOxygen-Free Copper Hollow Water-Cooled Magnet Conductor Profile
1–10 kV
Fixed, furnace & kiln
EN / HDOther
1–10 kV, EN / HD, Other sheathFixed, furnace & kiln

High-temperature wires

PTFE, FEP, silicone, glass-fibre and mica insulated wires for hot equipment.

57 cables
10mm 80kV Dual-Silicone Ignition cross-section showing core geometry and red outer profile
10mm 80kV Dual-Silicone Ignition10 mm 80 kV Dual-Silicone Wire-Wound Ignition Cable
80 kV
Fixed, furnace & kiln
Silicone
80 kV, , Silicone sheathFixed, furnace & kiln
AC Fire-Protected HC Cable cross-section showing core arrangement and red outer profile
AC Fire-Protected 500 °C High-Current Steel-Mill CableAC Fire-Protected 500 °C High-Current Steel-Mill Cable
1000 V
Fixed, motor & traction leads
DIN VDESilicone
1000 V, DIN VDE, Silicone sheathFixed, motor & traction leads
AC Induction 1000V 450°C Cable cross-section showing core arrangement and grey outer profile
AC Induction 1,000 V 450 °C Air-Cooled High-Current CableAC Induction 1,000 V 450 °C Air-Cooled High-Current Cable
1000 V
Fixed, furnace & kiln
DIN VDEGlass braid
1000 V, DIN VDE, Glass braid sheathFixed, furnace & kiln
CMP 83754 4×14 AWG Cable cross-section showing core geometry and red outer profile
CMP 83754 4×14 AWG 200 °C Plenum FEP Control CableCMP 83754 4×14 AWG 200 °C Plenum FEP Control Cable
300 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
300 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
VDE 5Y PTFE 600/1000V cross-section showing core geometry and red outer profile
VDE 5Y PTFE 600/1000VDIN VDE 5Y PTFE 600/1000 V 260 °C High-Temp Wire
600/1000 V
Furnace & kiln, control cabinet
DIN VDE
600/1000 V, DIN VDE, sheathFurnace & kiln, control cabinet
VDE 6Y FEP 600V cross-section showing core geometry and grey outer profile
VDE 6Y FEP 600VDIN VDE 6Y FEP 600 V 205 °C High-Temp Hook-Up Wire
600 V
Furnace & kiln, control cabinet
DIN VDE
600 V, DIN VDE, sheathFurnace & kiln, control cabinet
VDE 6Y Multi-Core FEP cross-section showing core geometry and black outer profile
VDE 6Y Multi-Core FEPDIN VDE 6Y Multi-Core 205 °C FEP Control Cable
300/500 V
Fixed, furnace & kiln
DIN VDEFluoropolymer
300/500 V, DIN VDE, Fluoropolymer sheathFixed, furnace & kiln
VDE 6YI1 205°C FEP cross-section showing core geometry and blue outer profile
VDE 6YI1 205°C FEPDIN VDE 6YI1 205 °C FEP High-Temp Equipment Wire
300/500 V
Furnace & kiln, control cabinet
DIN VDE
300/500 V, DIN VDE, sheathFurnace & kiln, control cabinet
FEP/FEP 600V 200°C Control cross-section showing core geometry and black outer profile
FEP/FEP 600 V 200 °C Multi-Core High-Temp Control CableFEP/FEP 600 V 200 °C Multi-Core High-Temp Control Cable
600 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
600 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
FZLSi 10/12 kV Ignition cross-section showing core geometry and red outer profile
FZLSi 10/12 kV IgnitionFZLSi 10/12 kV 180 °C Silicone Burner Ignition Cable
10/12 kV
Fixed, furnace & kiln
DIN VDE
10/12 kV, DIN VDE, sheathFixed, furnace & kiln
GN500-01 350°C Mica Wire cross-section showing core arrangement and white outer profile
GN500-01 350 °C 500 V Mica-Fibreglass High-Temp WireGN500-01 350 °C 500 V Mica-Fibreglass High-Temp Wire
500 V
Fixed, furnace & kiln
GB / MTSilicone
500 V, GB / MT, Silicone sheathFixed, furnace & kiln
KGG 450/750 V Control Cable cross-section showing core arrangement and black outer profile
KGG 450/750 V 180 °C Silicone Rubber Control CableKGG 450/750 V 180 °C Silicone Rubber Control Cable
450/750 V
Fixed, furnace & kiln
GB / MTSilicone
450/750 V, GB / MT, Silicone sheathFixed, furnace & kiln
KGGR 450/750 V Flex Cable cross-section showing core arrangement and red outer profile
KGGR 450/750 V 180 °C Flexible Silicone Control CableKGGR 450/750 V 180 °C Flexible Silicone Control Cable
450/750 V
Fixed, furnace & kiln
GB / MTSilicone
450/750 V, GB / MT, Silicone sheathFixed, furnace & kiln
MGT 450°C UL 5128/5107 Wire cross-section showing core arrangement and yellow outer profile
MGT 450 °C UL 5128 / 5107 600 V Mica-Glass WireMGT 450 °C UL 5128 / 5107 600 V Mica-Glass Wire
600 V
Fixed, furnace & kiln
UL / CSAGlass braid
600 V, UL / CSA, Glass braid sheathFixed, furnace & kiln
MIL-DTL-16878/4 Type E cross-section showing core geometry and white outer profile
MIL-DTL-16878/4 Type EMIL-DTL-16878/4 Type E 600 V PTFE Hook-Up Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
MIL-DTL-16878/5 Type EE cross-section showing core geometry and red outer profile
MIL-DTL-16878/5 Type EEMIL-DTL-16878/5 Type EE 1000 V PTFE Hook-Up Wire
1000 V
Furnace & kiln, control cabinet
1000 V, , sheathFurnace & kiln, control cabinet
MIL-DTL-16878/6 Type ET cross-section showing core geometry and blue outer profile
MIL-DTL-16878/6 Type ETMIL-DTL-16878/6 Type ET 250 V Thin-Wall PTFE Wire
250 V
Furnace & kiln, control cabinet
250 V, , sheathFurnace & kiln, control cabinet
N2GFAF 300/300 V cross-section showing core geometry and white outer profile
N2GFAF 300/300 VN2GFAF 300/300 V 180 °C Silicone Glass-Braid Wire
300/300 V
Furnace & kiln, motor & traction leads
DIN VDESilicone
300/300 V, DIN VDE, Silicone sheathFurnace & kiln, motor & traction leads
SAE AS22759/11 cross-section showing core geometry and white outer profile
SAE AS22759/11SAE AS22759/11 600 V 200 °C PTFE Aerospace Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE AS22759/16 cross-section showing core geometry and white outer profile
SAE AS22759/16SAE AS22759/16 600 V 150 °C ETFE Aerospace Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE AS22759/18 cross-section showing core geometry and yellow outer profile
SAE AS22759/18SAE AS22759/18 600 V 150 °C Thin-Wall ETFE Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE AS22759/34 cross-section showing core geometry and white outer profile
SAE AS22759/34SAE AS22759/34 600 V 150 °C XL-ETFE Aerospace Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE AS22759/41 cross-section showing core geometry and grey outer profile
SAE AS22759/41SAE AS22759/41 600 V 200 °C XL-ETFE Nickel-Cu Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE AS22759/80 cross-section showing core geometry and white outer profile
SAE AS22759/80SAE AS22759/80 600 V 200 °C PTFE/Polyimide Wire
600 V
Furnace & kiln, control cabinet
600 V, , sheathFurnace & kiln, control cabinet
SAE J2031 Class E Ignition Cable cross-section showing core geometry and black outer profile
SAE J2031 Class E 7 mm 220 °C Silicone Ignition CableSAE J2031 Class E 7 mm 220 °C Silicone Ignition Cable
40 kV
Fixed, furnace & kiln
Silicone
40 kV, , Silicone sheathFixed, furnace & kiln
SiD 300/500 V Solid cross-section showing core geometry and red outer profile
SiD 300/500 V SolidSiD 300/500 V 180 °C Solid Silicone Single-Core Wire
300/500 V
Fixed, furnace & kiln
DIN VDE
300/500 V, DIN VDE, sheathFixed, furnace & kiln
SiF 300/500 V cross-section showing core geometry and red outer profile
SiF 300/500 VSiF 300/500 V 180 °C Flexible Silicone Single-Core Wire
300/500 V
Furnace & kiln, motor & traction leads
DIN VDE
300/500 V, DIN VDE, sheathFurnace & kiln, motor & traction leads
SiF/GL 300/500 V cross-section showing core geometry and white outer profile
SiF/GL 300/500 VSiF/GL 300/500 V 180 °C Silicone Glass-Braid Wire
300/500 V
Furnace & kiln, motor & traction leads
DIN VDESilicone
300/500 V, DIN VDE, Silicone sheathFurnace & kiln, motor & traction leads
SiFF 300/500V Class 6 cross-section showing core geometry and blue outer profile
SiFF 300/500V Class 6SiFF 300/500 V 180 °C Class 6 Extra-Flex Silicone Wire
300/500 V
Furnace & kiln, motor & traction leads
DIN VDE
300/500 V, DIN VDE, sheathFurnace & kiln, motor & traction leads
SiHF/SiHF-J 300/500 V cross-section showing core geometry and red outer profile
SiHF/SiHF-J 300/500 VSiHF / SiHF-J 300/500 V 180 °C Multi-Core Silicone Cable
300/500 V
Furnace & kiln, motor & traction leads
DIN VDESilicone
300/500 V, DIN VDE, Silicone sheathFurnace & kiln, motor & traction leads
SiHF-GL-P / SiHF-GLS-P cross-section showing core geometry and grey outer profile
SiHF-GL-P / SiHF-GLS-PSiHF-GL-P 300/500 V 180 °C Steel-Braided Silicone Cable
300/500 V
Fixed, furnace & kiln
DIN VDESilicone
300/500 V, DIN VDE, Silicone sheathFixed, furnace & kiln
Silicone HC 1.8/3 kV Cable cross-section showing core arrangement and black outer profile
Silicone HC 1.8/3 kV 180 °C High-Current Flexible CableSilicone HC 1.8/3 kV 180 °C High-Current Flexible Cable
1.8/3 kV
Fixed, motor & traction leads
DIN VDE
1.8/3 kV, DIN VDE, sheathFixed, motor & traction leads
Silicone HC 3.6/6 kV Cable cross-section showing core arrangement and red outer profile
Silicone HC 3.6/6 kV 180 °C MV High-Current Flexible CableSilicone HC 3.6/6 kV 180 °C MV High-Current Flexible Cable
3.6/6 kV
Fixed, motor & traction leads
DIN VDE
3.6/6 kV, DIN VDE, sheathFixed, motor & traction leads
TGGT 250°C UL 5256/5257 Wire cross-section showing core arrangement and white outer profile
TGGT 250 °C UL 5256 / 5257 600 V PTFE-Glass WireTGGT 250 °C UL 5256 / 5257 600 V PTFE-Glass Wire
600 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
600 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
UL 5390/5400 550°C Mica Wire cross-section showing core arrangement and white outer profile
UL 5390 / 5400 550 °C 600 V Mica-Glass High-Temp WireUL 5390 / 5400 550 °C 600 V Mica-Glass High-Temp Wire
600 V
Fixed, furnace & kiln
UL / CSAGlass braid
600 V, UL / CSA, Glass braid sheathFixed, furnace & kiln
UL 10086 200°C ETFE cross-section showing core geometry and red outer profile
UL 10086 200°C ETFEUL AWM 10086 600 V 200 °C ETFE Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 10362 250°C PFA cross-section showing core geometry and orange outer profile
UL 10362 250°C PFAUL AWM 10362 600 V 250 °C PFA Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 10475 15-40 kVDC HV Wire cross-section showing core geometry and white outer profile
UL AWM 10475 15–40 kVDC High-Voltage Silicone WireUL AWM 10475 15–40 kVDC High-Voltage Silicone Wire
15–40 kV DC
Fixed, control cabinet
UL / CSA
15–40 kV DC, UL / CSA, sheathFixed, control cabinet
UL 11486 260°C PTFE cross-section showing core geometry and black outer profile
UL 11486 260°C PTFEUL AWM 11486 600 V 260 °C PTFE Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1180 300V PTFE cross-section showing core geometry and blue outer profile
UL 1180 300V PTFEUL AWM 1180 300 V 200 °C PTFE Hook-Up Wire
300 V
Furnace & kiln, control cabinet
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1213 PTFE Equipment Wire cross-section showing core geometry and green outer profile
UL AWM 1213 Thin-Wall PTFE Equipment Hook-Up WireUL AWM 1213 Thin-Wall PTFE Equipment Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1331 600V FEP cross-section showing core geometry and black outer profile
UL 1331 600V FEPUL AWM 1331 600 V 150 °C FEP Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1333 300V FEP cross-section showing core geometry and blue outer profile
UL 1333 300V FEPUL AWM 1333 300 V 150 °C FEP Thin-Wall Hook-Up Wire
300 V
Furnace & kiln, control cabinet
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1422/1516 ETFE Wire cross-section showing core geometry and blue outer profile
UL AWM 1422 / 1516 ETFE Thin-Wall Wire-Wrap WireUL AWM 1422 / 1516 ETFE Thin-Wall Wire-Wrap Wire
300 V
Furnace & kiln, control cabinet
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1726 300V PFA cross-section showing core geometry and yellow outer profile
UL 1726 300V PFAUL AWM 1726 300 V 250 °C PFA High-Temp Hook-Up Wire
300 V
Furnace & kiln, control cabinet
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1727 600V PFA cross-section showing core geometry and brown outer profile
UL 1727 600V PFAUL AWM 1727 600 V 250 °C PFA High-Temp Hook-Up Wire
600 V
Furnace & kiln, control cabinet
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 1815 300V PTFE cross-section showing core geometry and grey outer profile
UL 1815 300V PTFEUL AWM 1815 300 V 250 °C PTFE High-Temp Hook-Up Wire
300 V
Furnace & kiln, control cabinet
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, control cabinet
UL 20221/20222 ETFE cross-section showing core geometry and grey outer profile
UL 20221/20222 ETFEUL AWM 20221 / 20222 150 °C Multi-Core ETFE Cable
300 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
300 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
UL 20710 Thin-Wall FEP cross-section showing core geometry and black outer profile
UL 20710 Thin-Wall FEPUL AWM 20710 600 V 200 °C Thin-Wall FEP Control Cable
600 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
600 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
UL 21618 (TD 833 CF) Cable cross-section showing core geometry and white outer profile
UL AWM 21618 (TD 833 CF) 200 °C Screened FEP CableUL AWM 21618 (TD 833 CF) 200 °C Screened FEP Cable
300 V
Fixed, furnace & kiln
UL / CSAFluoropolymer
300 V, UL / CSA, Fluoropolymer sheathFixed, furnace & kiln
UL 3122 / SF-1 Wire cross-section showing core geometry and grey outer profile
UL AWM 3122 (SF-1) 300 V 200 °C Silicone Fixture WireUL AWM 3122 (SF-1) 300 V 200 °C Silicone Fixture Wire
300 V
Furnace & kiln, motor & traction leads
UL / CSASilicone
300 V, UL / CSA, Silicone sheathFurnace & kiln, motor & traction leads
UL 3139 600V Silicone cross-section showing core geometry and black outer profile
UL 3139 600V SiliconeUL AWM 3139 600 V 150 °C Braidless Silicone Lead Wire
600 V
Furnace & kiln, motor & traction leads
UL / CSA
600 V, UL / CSA, sheathFurnace & kiln, motor & traction leads
UL 3367 300V Silicone cross-section showing core geometry and white outer profile
UL 3367 300V SiliconeUL AWM 3367 300 V 150 °C Braidless Silicone Wire
300 V
Furnace & kiln, motor & traction leads
UL / CSA
300 V, UL / CSA, sheathFurnace & kiln, motor & traction leads
UL 5196 PTFE Glass Wire cross-section showing core geometry and white outer profile
UL AWM 5196 600 V 250 °C PTFE + Glass-Braid WireUL AWM 5196 600 V 250 °C PTFE + Glass-Braid Wire
600 V
Furnace & kiln, control cabinet
UL / CSAFluoropolymer
600 V, UL / CSA, Fluoropolymer sheathFurnace & kiln, control cabinet
YGC 0.6/1 kV Silicone Cable cross-section showing core arrangement and red outer profile
YGC 0.6/1 kV 180 °C Silicone Rubber High-Temp Power CableYGC 0.6/1 kV 180 °C Silicone Rubber High-Temp Power Cable
0.6/1 kV
Fixed, furnace & kiln
GB / MTSilicone
0.6/1 kV, GB / MT, Silicone sheathFixed, furnace & kiln
YGCR 0.6/1 kV Flexible Cable cross-section showing core arrangement and grey outer profile
YGCR 0.6/1 kV 180 °C Extra-Flexible Silicone Power CableYGCR 0.6/1 kV 180 °C Extra-Flexible Silicone Power Cable
0.6/1 kV
Fixed, furnace & kiln
GB / MTSilicone
0.6/1 kV, GB / MT, Silicone sheathFixed, furnace & kiln
H05SS-F / SiHF-EWKF 180 °C Silicone Pump Motor Lead Cable
H05SS-F / SiHF-EWKFH05SS-F / SiHF-EWKF 180 °C Silicone Pump Motor Lead Cable
300/500 V
Multi-layer drum (limited), free-hanging (limited), fixed, submerged (limited)
EN / HDSilicone
300/500 V, EN / HD, Silicone sheathMulti-layer drum (limited), free-hanging (limited), fixed, submerged (limited)

Hook-up wire & equipment cables

Equipment wires for panels, vehicles and rolling stock, from UL AWM to EN 50306.

3 cables
GTO CABLE 15kVAC — cable cross-section
GTO CABLE 15kVACUL GTO-15 15 kVAC Silicone/PVC High-Voltage Gas-Tube-Sign Wire
15 kVAC
Furnace & kiln, control cabinet
UL / CSAPVC
15 kVAC, UL / CSA, PVC sheathFurnace & kiln, control cabinet
H05V2V2-F — cable cross-section
H05V2V2-FH05V2V2-F 300/500 V +90 °C Heat-Resistant PVC Flexible Cord
300/500 V
Fixed, control cabinet
EN / HDPVC
300/500 V, EN / HD, PVC sheathFixed, control cabinet
HPN — cable cross-section
HPNUL HPN 300 V +90 °C Parallel CPE/Neoprene Heater & Appliance Cord
300 V
Furnace & kiln, control cabinet
UL / CSARubber
300 V, UL / CSA, Rubber sheathFurnace & kiln, control cabinet

Power & connection cables

From 100 V welding leads to 45 kV feeders, with portable cords, EV charging and solar cables.

20 cables
AC Welding Jumper Cable cross-section showing core arrangement and black outer profile
AC Air-Cooled High-Current Welding Transformer JumperAC Air-Cooled High-Current Welding Transformer Jumper
600 V
Fixed, motor & traction leads
EN / HDRubber
600 V, EN / HD, Rubber sheathFixed, motor & traction leads
AC Bare-Cu Braid Shunt cross-section showing core arrangement and orange outer profile
AC Bare-Cu Braid ShuntAC Bare Copper Flat Braided Flexible Shunt & Busbar Strap
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
AC Bare-Cu Rope 120-700 cross-section showing core arrangement and red outer profile
AC Bare-Cu Rope 120-700AC Bare Copper Flexible Rope 120–700 mm² Uninsulated Lead
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
AC Isolated-Rope Jumper cross-section showing core arrangement and black outer profile
AC Isolated-Rope Air-Cooled High-Current Jumper CableAC Isolated-Rope Air-Cooled High-Current Jumper Cable
1000 V
Fixed, motor & traction leads
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, motor & traction leads
AC Laminated Cu-Foil Lead cross-section showing core arrangement and orange outer profile
AC Laminated Copper-Foil Flexible Busbar Expansion LeadAC Laminated Copper-Foil Flexible Busbar Expansion Lead
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
AC Ventilated Weld Cable cross-section showing core arrangement and blue outer profile
AC Ventilated Air-Cooled High-Current Welding CableAC Ventilated Air-Cooled High-Current Welding Cable
600 V
Fixed, motor & traction leads
EN / HDRubber
600 V, EN / HD, Rubber sheathFixed, motor & traction leads
ACC 300-800 Air-Cooled Cable cross-section showing core arrangement and black outer profile
ACC 300–800 mm² Air-Cooled High-Current Jumper CableACC 300–800 mm² Air-Cooled High-Current Jumper Cable
1000 V
Fixed, motor & traction leads
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, motor & traction leads
EAF Heat-Shield 500°C Cable cross-section showing core arrangement and black outer profile
EAF 500 °C Heat-Shielded Water-Cooled Furnace CableEAF 500 °C Heat-Shielded Water-Cooled Furnace Cable
1000 V
Fixed, furnace & kiln
DIN VDEGlass braid
1000 V, DIN VDE, Glass braid sheathFixed, furnace & kiln
EAF Anti-Chafing Bumper Cable cross-section showing core arrangement and grey outer profile
EAF Anti-Chafing Bumper Water-Cooled Furnace CableEAF Anti-Chafing Bumper Water-Cooled Furnace Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
EAF Swivel-End Sleeved Cable cross-section showing core arrangement and black outer profile
EAF Swivel-End & Anti-Abrasion Sleeved Water-Cooled CableEAF Swivel-End & Anti-Abrasion Sleeved Water-Cooled Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
EAF Wear-Indicator Hose Cable cross-section showing core arrangement and black outer profile
EAF Water-Cooled Cable with Dual-Layer Wear-Indicator HoseEAF Water-Cooled Cable with Dual-Layer Wear-Indicator Hose
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
SAF Water-Cooled Cable cross-section showing core arrangement and black outer profile
SAF Submerged Arc Furnace Water-Cooled Feeder CableSAF Submerged Arc Furnace Water-Cooled Feeder Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
UL Tinned-Cu Braid Strap cross-section showing core arrangement and grey outer profile
UL Tinned-Cu Braid StrapUL Tinned Copper Flat Grounding & Bonding Braid Strap
600 V
Fixed, control cabinet
UL / CSA
600 V, UL / CSA, sheathFixed, control cabinet
WC Center-Channel 95-500 Cable cross-section showing core arrangement and black outer profile
WC Center-Channel 95–500 mm² Water-Cooled Power CableWC Center-Channel 95–500 mm² Water-Cooled Power Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Hollow-Core 10kHz Litz cross-section showing core arrangement and black outer profile
WC Hollow-Core 10kHz LitzWC Hollow-Core 10 kHz Litz Water-Cooled Induction Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Hollow-Core 2 kHz Cable cross-section showing core arrangement and black outer profile
WC Hollow-Core 2 kHz Water-Cooled Induction CableWC Hollow-Core 2 kHz Water-Cooled Induction Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Multi-Rope 1200-2000 Cable cross-section showing core arrangement and black outer profile
WC Multi-Rope 1,200–2,000 mm² Ultra-High-Current CableWC Multi-Rope 1,200–2,000 mm² Ultra-High-Current Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Single-Core 120-1000 Cable cross-section showing core arrangement and black outer profile
WC Single-Core 120–1,000 mm² Water-Cooled Feeder CableWC Single-Core 120–1,000 mm² Water-Cooled Feeder Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Tin-Plated 3000 V Cable cross-section showing core arrangement and black outer profile
WC Tin-Plated 3,000 V Water-Cooled HV Induction CableWC Tin-Plated 3,000 V Water-Cooled HV Induction Cable
3000 V
Fixed, furnace & kiln
DIN VDERubber
3000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Unipolar Weld Cable cross-section showing core arrangement and black outer profile
WC Unipolar 120–500 mm² Water-Cooled Welding CableWC Unipolar 120–500 mm² Water-Cooled Welding Cable
600 V
Fixed, furnace & kiln
DIN VDERubber
600 V, DIN VDE, Rubber sheathFixed, furnace & kiln

Choosing high temperature cable

Four things decide most selections. Our engineers check the rest against your application.

01 · Mechanical duty & installation profile

  • Match minimum bending radius, travel speed, and tensile load to the active duty profile (Cylindrical / multi-layer drum, Free-hanging vertical run, Fixed installation, Submerged / in water).
  • For continuous reeling, festoon, or drag-chain motion, specify fine-stranded Class 5/6 copper conductors with central strain-relief or anti-torsion braid.

02 · Rated voltage & cable family scope

  • This collection spans Heating cables, Fire-resistant & fire alarm cables, Instrumentation cables, Industrial data & RF cables, grouped below so power feeders, control circuits, and data/optical links can be specified side by side.
  • Account for voltage drop, ambient temperature derating, and symmetrical EMC screening on long runs or VFD motor drives.

03 · Standards compliance & outer sheath compound

  • Verify the governing regional or industry standard required by the project specification (IEC, VDE/DIN, UL, BS, ICEA/MSHA, etc.).
  • Use the outer-sheath filter to lock in PUR, heavy-duty EPR/PCP rubber, or low-smoke zero-halogen (LSZH) compounds for oil, abrasion, or fire safety.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
What rated voltages are available in the High Temperature Cable category?

Rated voltages run from 230 V to 500 kV across 110 of the 119 products. The most common rating is 600 V, listed for 26 products.

Which standards do the products in the High Temperature Cable category reference?

The products reference IEC Standard (77 products), UL Standard (48 products), VDE / DIN Standard (46 products), CSA C22.2 / C68.10 (19 products), MIL-DTL / MIL-SPEC (13 products), EN / CENELEC (4 products), ICEA Standard (4 products), IEEE 1580 Standard (4 products), and ISO 6722 / ISO 19642 / SAE (2 products).

Are PDF datasheets available for the products in the High Temperature Cable category?

Yes. All 119 products have a PDF datasheet, linked from each product card and product page.

Engineering reference

Background on how high temperature cable are built, rated and specified.

Read the full reference

The High Temperature Cable collection brings together 119 industrial cable models across Heating cables, Fire-resistant & fire alarm cables, Instrumentation cables, Industrial data & RF cables, Overhead conductors, Magnet & winding wires. Cables for elevated ambient and radiant heat service conditions.

Use the multi-facet filter bar and duty matrix view to compare rated voltage, governing standard, outer sheath compound, and mechanical duty ratings side by side, or add candidate models to a combined engineering enquiry.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features