ACIC Type JX Interlocked Aluminum Armored Thermocouple ExtensionCSA C22.2 No. 239 / ANSI MC96.1 · 300 V · -40 °C to +90 °C industrial ACIC THERMOCOUPLE JX

ACIC Type JX Interlocked Aluminum Armored Thermocouple Extension Cable (ACIC THERMOCOUPLE JX) engineered to CSA C22.2 No. 239 / ANSI MC96.1 for 300 V service across -40 °C to +90 °C, featuring stranded iron / copper nickel / tinned copper conductor and black

Approved
Low-EMC design
EMC screen
Order designation
ACIC THERMOCOUPLE JX 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V
Per CSA C22.2 No. 239 / ANSI MC96.1
Operating temp.
−40…+90 °C
Continuous thermal rating
Min. bend radius
12 × OD
Installed / fixed routing
Conductor
iron / copper
High-conductivity iron / copper
Outer layer
Black PVC outer
Extruded Black PVC outer jacket
Standard
CSA C22.2 No.
CSA C22.2 No. 239 / ANSI MC96.1

Typical values for this cable type, based on CSA C22.2 No. 239 / ANSI MC96.1 — confirmed in the datasheet and quotation for your order.

Application fit

Is ACIC Type JX right for your machine?

ACIC Type JX Interlocked Aluminum Armored Thermocouple Extension Cable (ACIC THERMOCOUPLE JX) engineered to CSA C22.2 No. 239 / ANSI MC96.1 for 300 V service across -40 °C to +90 °C, featuring stranded iron / copper nickel / tinned copper conductor and black

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with CSA C22.2 No. 239 / ANSI MC96.1.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 12 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesOil & Gas CableRefinery & Petrochemical Process UnitsLNG Terminals & Tank FarmsOnshore & Offshore Oil & Gas FacilitiesChemical & Hydrocarbon Processing PlantsMetallurgical, Glass & Ceramic Furnaces

Construction

Layer by layer

Shown: ACIC THERMOCOUPLE JX (CSA C22.2 No. 239 / ANSI MC96.1) with stranded iron / copper nickel / tinned copper conductor, individual al/pet screen and black pvc outer jacket (8-layer construction).

12345678
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded iron / copper nickel / tinned copper conductorHigh-conductivity iron / copper nickel / tinned copper conductor per CSA C22.2 No. 239 / ANSI MC96.1CSA C22.2 No. 239 / ANSI MC96.1
2Individual Al/PET screenIndividual Al/PET screen metallic electromagnetic screen (individual core / group layer)CSA C22.2 No. 239 / ANSI MC96.1
3XLPE core insulationExtruded XLPE dielectric (individual core / group layer)CSA C22.2 No. 239 / ANSI MC96.1
4Polyester binderHelically applied polyester binderCSA C22.2 No. 239 / ANSI MC96.1
5Overall Al/PET screenOverall Al/PET screen metallic electromagnetic screen (lapped tape)CSA C22.2 No. 239 / ANSI MC96.1
6Black PVC inner jacketExtruded Black PVC inner jacket protective layer (continuous layer)CSA C22.2 No. 239 / ANSI MC96.1
7Aluminium interlocked armourAluminium interlocked armour mechanical protection (interlocked armour)CSA C22.2 No. 239 / ANSI MC96.1
8Black PVC outer jacketExtruded Black PVC outer jacket protective layer (continuous layer)CSA C22.2 No. 239 / ANSI MC96.1

ACIC THERMOCOUPLE JX — Standard Execution

Built to CSA C22.2 No. 239 / ANSI MC96.1 with stranded iron / copper nickel / tinned copper conductor and

ACIC THERMOCOUPLE JX — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per CSA C22.2 No. 239 / ANSI MC96.1

ACIC THERMOCOUPLE JX — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on CSA C22.2 No. 239 / ANSI MC96.1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300 V (CSA C22.2 No. 239 / ANSI MC96.1)
Conductor construction
Stranded iron / copper nickel / tinned copper conductor — High-conductivity iron / copper nickel / tinned copper conductor per CSA C22.2 No. 239 / ANSI MC96.1
Primary insulation / dielectric
Individual Al/PET screen — Individual Al/PET screen metallic electromagnetic screen (individual core / group layer)

Thermal

Continuous operating temperature
−40…+90 °C per CSA C22.2 No. 239 / ANSI MC96.1
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Black PVC outer jacket — Extruded Black PVC outer jacket protective layer (continuous layer)
Minimum bending radius
12 × OD (installed / static routing)
Layer count & geometry
8 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with CSA C22.2 No. 239 / ANSI MC96.1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
CSA C22.2 No. 239 / ANSI MC96.1
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
ACIC THERMOCOUPLE JX
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard ACIC THERMOCOUPLE JX cable configurations

Manufactured to CSA C22.2 No. 239 / ANSI MC96.1 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
ACIC THERMOCOUPLE JX Standard Construction Schedule (300 V · −40…+90 °C)
ACIC THERMOCOUPLE JX 1×2×0.51×2×0.5 mm²6.45852
ACIC THERMOCOUPLE JX 2×2×0.52×2×0.5 mm²9.211274
ACIC THERMOCOUPLE JX 4×2×0.54×2×0.5 mm²11.417692
ACIC THERMOCOUPLE JX 8×2×0.58×2×0.5 mm²14.8295118
ACIC THERMOCOUPLE JX 12×2×0.512×2×0.5 mm²17.6420141
ACIC THERMOCOUPLE JX 1×2×1.01×2×1.0 mm²7.68661
ACIC THERMOCOUPLE JX 2×2×1.02×2×1.0 mm²11.016888
ACIC THERMOCOUPLE JX 4×2×1.04×2×1.0 mm²13.5264108
ACIC THERMOCOUPLE JX 8×2×1.08×2×1.0 mm²17.9465143
ACIC THERMOCOUPLE JX 1×2×1.51×2×1.5 mm²8.511468
ACIC THERMOCOUPLE JX 4×2×1.54×2×1.5 mm²15.2348122
ACIC THERMOCOUPLE JX 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per CSA C22.2 No. 239 / ANSI MC96.1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (CSA C22.2 No. 239 / ANSI MC96.1)DC resistance at 20 °C and geometry within CSA C22.2 No. 239 / ANSI MC96.1 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (CSA C22.2 No. 239 / ANSI MC96.1)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (CSA C22.2 No. 239 / ANSI MC96.1)Full compliance with CSA C22.2 No. 239 / ANSI MC96.1 across −40…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

CSA C22.2 No. 239 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX ACIC THERMOCOUPLE JX <size> CSA C22.2 No. 239 300 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define ACIC THERMOCOUPLE JX (ACIC Type JX Interlocked Aluminum Armored Thermocouple Extension Cable)?
ACIC THERMOCOUPLE JX (ACIC Type JX Interlocked Aluminum Armored Thermocouple Extension Cable) is manufactured in accordance with CSA C22.2 No. 239 / ANSI MC96.1 for 300 V service over -40 °C to +90 °C. Its 8-layer construction comprises stranded iron / copper nickel / tinned copper conductor, individual al/pet screen, xlpe core insulation, polyester binder, overall al/pet screen, black pvc inner jacket, aluminium interlocked armour, black pvc outer jacket.
What is the minimum bending radius and installation temperature for ACIC THERMOCOUPLE JX?
The minimum installed bending radius for ACIC THERMOCOUPLE JX is 12 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of ACIC THERMOCOUPLE JX arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded iron / copper nickel / tinned copper conductor (High-conductivity iron / copper nickel / tinned copper conductor per CSA C22.2 No. 239 / ANSI MC96.1); (02) Individual Al/PET screen (Individual Al/PET screen metallic electromagnetic screen (individual core / group layer)); (03) XLPE core insulation (Extruded XLPE dielectric (individual core / group layer)); (04) Polyester binder (Helically applied polyester binder); (05) Overall Al/PET screen (Overall Al/PET screen metallic electromagnetic screen (lapped tape)); (06) Black PVC inner jacket (Extruded Black PVC inner jacket protective layer (continuous layer)); (07) Aluminium interlocked armour (Aluminium interlocked armour mechanical protection (interlocked armour)); (08) Black PVC outer jacket (Extruded Black PVC outer jacket protective layer (continuous layer)).
What factory test certificates are supplied with ACIC THERMOCOUPLE JX?
Every production drum or spool of ACIC THERMOCOUPLE JX undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per CSA C22.2 No. 239 / ANSI MC96.1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for ACIC Type JX

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

ACIC Type JX Interlocked Aluminum Armored Thermocouple Extension

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 