Type JX Thermocouple Extension + 5G1.5 Control Composite CableIEC 60584-3 / DIN VDE 0285 · 300/500 V · -30 °C to +90 °C industrial TC-JX Hybrid construction

Type JX Thermocouple Extension + 5G1.5 Control Composite Cable (TC-JX Hybrid (2×2×0.5 JX + 5G1.5)) engineered to IEC 60584-3 / DIN VDE 0285 for 300/500 V service across -30 °C to +90 °C, featuring stranded iron / copper nickel / copper conductor and pvc outer

Approved
Low-EMC design
EMC screen
Oil-resistant
Order designation
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Per IEC 60584-3 / DIN VDE 0285
Operating temp.
−30…+90 °C
Continuous thermal rating
Min. bend radius
7.5 × OD
Installed / fixed routing
Conductor
iron / copper
High-conductivity iron / copper
Outer layer
PVC outer sheath
Extruded PVC outer sheath protective
Standard
IEC 60584-3
IEC 60584-3 / DIN VDE 0285

Typical values for this cable type, based on IEC 60584-3 / DIN VDE 0285 — confirmed in the datasheet and quotation for your order.

Application fit

Is TC-JX Hybrid (2×2×0.5 JX + 5G1.5) right for your machine?

Type JX Thermocouple Extension + 5G1.5 Control Composite Cable (TC-JX Hybrid (2×2×0.5 JX + 5G1.5)) engineered to IEC 60584-3 / DIN VDE 0285 for 300/500 V service across -30 °C to +90 °C, featuring stranded iron / copper nickel / copper conductor and pvc outer

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with IEC 60584-3 / DIN VDE 0285.

Furnace, kiln & high-temp zone

Suitable

Engineered and verified for furnace kiln service in accordance with IEC 60584-3 / DIN VDE 0285.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 7.5 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Typical machinesIndustrial Automation CableAutomated Assembly & Packaging LinesCNC Machine Tools & RoboticsPLC/DCS Control & Marshalling CabinetsIndustrial Drives & Motor ManufacturingMetallurgical, Glass & Ceramic Furnaces

Construction

Layer by layer

Shown: TC-JX Hybrid (2×2×0.5 JX + 5G1.5) (IEC 60584-3 / DIN VDE 0285) with stranded iron / copper nickel / copper conductor, thermocouple element tinned copper braid and pvc outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded iron / copper nickel / copper conductorHigh-conductivity iron / copper nickel / copper conductor per IEC 60584-3 / DIN VDE 0285IEC 60584-3 / DIN VDE 0285
2Thermocouple element tinned copper braidThermocouple element tinned copper braid high-coverage braided layer (individual core / group layer)IEC 60584-3 / DIN VDE 0285
3PVC core insulationExtruded PVC dielectric (individual core / group layer)IEC 60584-3 / DIN VDE 0285
4Wrapping and bandingHelically applied wrapping and bandingIEC 60584-3 / DIN VDE 0285
5PVC outer sheathExtruded PVC outer sheath protective layer (continuous layer)IEC 60584-3 / DIN VDE 0285

TC-JX Hybrid (2×2×0.5 JX + 5G1.5) — Standard Execution

Built to IEC 60584-3 / DIN VDE 0285 with stranded iron / copper nickel / copper conductor and pvc outer sheath

TC-JX Hybrid (2×2×0.5 JX + 5G1.5) — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per IEC 60584-3 / DIN VDE 0285

TC-JX Hybrid (2×2×0.5 JX + 5G1.5) — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60584-3 / DIN VDE 0285. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
300/500 V (IEC 60584-3 / DIN VDE 0285)
Conductor construction
Stranded iron / copper nickel / copper conductor — High-conductivity iron / copper nickel / copper conductor per IEC 60584-3 / DIN VDE 0285
Primary insulation / dielectric
Thermocouple element tinned copper braid — Thermocouple element tinned copper braid high-coverage braided layer (individual core / group layer)

Thermal

Continuous operating temperature
−30…+90 °C per IEC 60584-3 / DIN VDE 0285
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer sheath — Extruded PVC outer sheath protective layer (continuous layer)
Minimum bending radius
7.5 × OD (installed / static routing)
Layer count & geometry
5 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with IEC 60584-3 / DIN VDE 0285
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
IEC 60584-3 / DIN VDE 0285
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TC-JX Hybrid (2×2×0.5 JX + 5G1.5)
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard TC-JX Hybrid (2×2×0.5 JX + 5G1.5) cable configurations

Manufactured to IEC 60584-3 / DIN VDE 0285 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) Standard Construction Schedule (300/500 V · −30…+90 °C)
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×0.51×2×0.5 mm²6.45852
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 2×2×0.52×2×0.5 mm²9.211274
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×0.54×2×0.5 mm²11.417692
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 8×2×0.58×2×0.5 mm²14.8295118
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 12×2×0.512×2×0.5 mm²17.6420141
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×1.01×2×1.0 mm²7.68661
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 2×2×1.02×2×1.0 mm²11.016888
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×1.04×2×1.0 mm²13.5264108
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 8×2×1.08×2×1.0 mm²17.9465143
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 1×2×1.51×2×1.5 mm²8.511468
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 4×2×1.54×2×1.5 mm²15.2348122
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per IEC 60584-3 / DIN VDE 0285.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60584-3 / DIN VDE 0285)DC resistance at 20 °C and geometry within IEC 60584-3 / DIN VDE 0285 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (IEC 60584-3 / DIN VDE 0285)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (IEC 60584-3 / DIN VDE 0285)Full compliance with IEC 60584-3 / DIN VDE 0285 across −30…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60584-3 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TC-JX Hybrid (2×2×0.5 JX + 5G1.5) <size> IEC 60584-3 300/500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TC-JX Hybrid (2×2×0.5 JX + 5G1.5) (Type JX Thermocouple Extension + 5G1.5 Control Composite Cable)?
TC-JX Hybrid (2×2×0.5 JX + 5G1.5) (Type JX Thermocouple Extension + 5G1.5 Control Composite Cable) is manufactured in accordance with IEC 60584-3 / DIN VDE 0285 for 300/500 V service over -30 °C to +90 °C. Its 5-layer construction comprises stranded iron / copper nickel / copper conductor, thermocouple element tinned copper braid, pvc core insulation, wrapping and banding, pvc outer sheath.
What is the minimum bending radius and installation temperature for TC-JX Hybrid (2×2×0.5 JX + 5G1.5)?
The minimum installed bending radius for TC-JX Hybrid (2×2×0.5 JX + 5G1.5) is 7.5 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of TC-JX Hybrid (2×2×0.5 JX + 5G1.5) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded iron / copper nickel / copper conductor (High-conductivity iron / copper nickel / copper conductor per IEC 60584-3 / DIN VDE 0285); (02) Thermocouple element tinned copper braid (Thermocouple element tinned copper braid high-coverage braided layer (individual core / group layer)); (03) PVC core insulation (Extruded PVC dielectric (individual core / group layer)); (04) Wrapping and banding (Helically applied wrapping and banding); (05) PVC outer sheath (Extruded PVC outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with TC-JX Hybrid (2×2×0.5 JX + 5G1.5)?
Every production drum or spool of TC-JX Hybrid (2×2×0.5 JX + 5G1.5) undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per IEC 60584-3 / DIN VDE 0285, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TC-JX Hybrid (2×2×0.5 JX + 5G1.5)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TC-JX Hybrid (2×2×0.5 JX + 5G1.5) Type JX Thermocouple Extension + 5G1.5 Control Composite Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote