Contact

IEC 60317-48 Class 200 Polyester-Glass Yarn Covered WireIEC 60317-48 / NEMA MW 50-C · Up to 3.6 kV · -40 °C to +200 °C industrial POLYESTER-GLASS

IEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn Covered Copper Winding Wire (POLYESTER-GLASS ENAMEL WIRE) engineered to IEC 60317-48 / NEMA MW 50-C for Up to 3.6 kV service across -40 °C to +200 °C, featuring stranded copper conductor and

Approved
Flame-retardant
Oil-resistant
Order designation
POLYESTER-GLASS ENAMEL WIRE Ø 1.00 mm
Max. overall Ø
1.08 mm
Total weight ≈
7.08 kg/km
Min. mandrel R
5 mm
Nominal conductor
Ø 1.00 mm (AWG 18)
All sizes (10)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Up to 3.6 kV
Per IEC 60317-48 / NEMA MW 50-C
Operating temp.
−40…+200 °C
Continuous thermal rating
Min. bend radius
6 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
Polyester-glass
Polyester-glass serving high-coverage
Standard
IEC 60317-48
IEC 60317-48 / NEMA MW 50-C

Typical values for this cable type, based on IEC 60317-48 / NEMA MW 50-C — confirmed in the datasheet and quotation for your order.

Application fit

Is IEC 60317-48 Class 200 right for your machine?

IEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn Covered Copper Winding Wire (POLYESTER-GLASS ENAMEL WIRE) engineered to IEC 60317-48 / NEMA MW 50-C for Up to 3.6 kV service across -40 °C to +200 °C, featuring stranded copper conductor and

Motor stator, traction & converter leads

Suitable

Engineered and verified for motor lead service in accordance with IEC 60317-48 / NEMA MW 50-C.

Furnace, kiln & high-temp zone

Suitable

Engineered and verified for furnace kiln service in accordance with IEC 60317-48 / NEMA MW 50-C.

Fixed installation

Suitable

Qualified for fixed installation on trays, racks, conduits or supports per IEC 60317-48 / NEMA MW 50-C.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 6 × OD bend radius.

Typical machinesRailway & TransitMetallurgical, Glass & Ceramic FurnacesHigh-Temperature Thermal ProcessingHeavy Industrial Kilns & OvensPower Generation & Petrochemical Heaters25 kV AC & 1.5/3 kV DC Railway Overhead Catenary

Construction

Layer by layer

Shown: POLYESTER-GLASS ENAMEL WIRE (IEC 60317-48 / NEMA MW 50-C) with stranded copper conductor, polyester enamel base and polyester-glass serving (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per IEC 60317-48 / NEMA MW 50-CIEC 60317-48 / NEMA MW 50-C
2Polyester enamel basePolyester enamel base (continuous layer)IEC 60317-48 / NEMA MW 50-C
3Polyamide-imide enamel overcoatPolyamide-imide enamel overcoat (continuous layer)IEC 60317-48 / NEMA MW 50-C
4Polyester-glass servingPolyester-glass serving high-coverage braided layer (woven structure)IEC 60317-48 / NEMA MW 50-C

POLYESTER-GLASS ENAMEL WIRE — Standard Execution

Built to IEC 60317-48 / NEMA MW 50-C with stranded copper conductor and polyester-glass serving

POLYESTER-GLASS ENAMEL WIRE — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per IEC 60317-48 / NEMA MW 50-C

POLYESTER-GLASS ENAMEL WIRE — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60317-48 / NEMA MW 50-C. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
Up to 3.6 kV (IEC 60317-48 / NEMA MW 50-C)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per IEC 60317-48 / NEMA MW 50-C
Primary insulation / dielectric
Polyester enamel base — Polyester enamel base (continuous layer)

Thermal

Continuous operating temperature
−40…+200 °C per IEC 60317-48 / NEMA MW 50-C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Polyester-glass serving — Polyester-glass serving high-coverage braided layer (woven structure)
Minimum bending radius
6 × OD (installed / static routing)
Layer count & geometry
4 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with IEC 60317-48 / NEMA MW 50-C
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
IEC 60317-48 / NEMA MW 50-C
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
POLYESTER-GLASS ENAMEL WIRE
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

10 standard POLYESTER-GLASS ENAMEL WIRE winding & resistance wire dimensions

Precision drawn and insulated to IEC 60317-48 / NEMA MW 50-C in Grade 1 / Grade 2 builds and rectangular profiles.

Nominal conductor diameter, overall Ø & weight
Order designationNominal conductorMax. overall Ø
mm
Weight ≈
kg/km
Min. mandrel R
mm
Enquiry
POLYESTER-GLASS ENAMEL WIRE Standard Precision Winding Schedule (−40…+200 °C)
POLYESTER-GLASS ENAMEL WIRE Ø 0.25 mmØ 0.25 mm (AWG 30)0.290.452
POLYESTER-GLASS ENAMEL WIRE Ø 0.40 mmØ 0.40 mm (AWG 26)0.451.142
POLYESTER-GLASS ENAMEL WIRE Ø 0.63 mmØ 0.63 mm (AWG 22)0.692.823
POLYESTER-GLASS ENAMEL WIRE Ø 0.80 mmØ 0.80 mm (AWG 20)0.874.544
POLYESTER-GLASS ENAMEL WIRE Ø 1.00 mmØ 1.00 mm (AWG 18)1.087.085
POLYESTER-GLASS ENAMEL WIRE Ø 1.25 mmØ 1.25 mm (AWG 16)1.3411.006
POLYESTER-GLASS ENAMEL WIRE Ø 1.60 mmØ 1.60 mm (AWG 14)1.7018.108
POLYESTER-GLASS ENAMEL WIRE Ø 2.00 mmØ 2.00 mm (AWG 12)2.1128.2010
POLYESTER-GLASS ENAMEL WIRE Ø 2.50 mmØ 2.50 mm (AWG 10)2.6244.1013
POLYESTER-GLASS ENAMEL WIRE Ø 3.15 mmØ 3.15 mm (AWG 8)3.2870.0016
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Supplied on precision PT25 / PT45 / PT90 / Din 355 conical and cylindrical winding spools per IEC 60317-48 / NEMA MW 50-C.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 60317-48 / NEMA MW 50-C)DC resistance at 20 °C and geometry within IEC 60317-48 / NEMA MW 50-C class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (IEC 60317-48 / NEMA MW 50-C)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (IEC 60317-48 / NEMA MW 50-C)Full compliance with IEC 60317-48 / NEMA MW 50-C across −40…+200 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60317-48 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX POLYESTER-GLASS ENAMEL WIRE <size> IEC 60317-48 Up to 3.6 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define POLYESTER-GLASS ENAMEL WIRE (IEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn Covered Copper Winding Wire)?
POLYESTER-GLASS ENAMEL WIRE (IEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn Covered Copper Winding Wire) is manufactured in accordance with IEC 60317-48 / NEMA MW 50-C for Up to 3.6 kV service over -40 °C to +200 °C. Its 4-layer construction comprises stranded copper conductor, polyester enamel base, polyamide-imide enamel overcoat, polyester-glass serving.
What is the minimum bending radius and installation temperature for POLYESTER-GLASS ENAMEL WIRE?
The minimum installed bending radius for POLYESTER-GLASS ENAMEL WIRE is 6 × OD across its continuous operating temperature range of -40 °C to +200 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of POLYESTER-GLASS ENAMEL WIRE arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per IEC 60317-48 / NEMA MW 50-C); (02) Polyester enamel base (Polyester enamel base (continuous layer)); (03) Polyamide-imide enamel overcoat (Polyamide-imide enamel overcoat (continuous layer)); (04) Polyester-glass serving (Polyester-glass serving high-coverage braided layer (woven structure)).
What factory test certificates are supplied with POLYESTER-GLASS ENAMEL WIRE?
Every production drum or spool of POLYESTER-GLASS ENAMEL WIRE undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per IEC 60317-48 / NEMA MW 50-C, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for IEC 60317-48 Class 200

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

IEC 60317-48 Class 200 Polyester-Glass Yarn Covered Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote