Contact

Type SH 5–35 kV MSHA Single-Conductor Shielded Power CableType SH 5 kV to 35 kV MSHA-approved single-conductor shielded medium-voltage portable power cable per ICEA S-75-381 for mobile mine substations and draglines, with Class K tinned copper, 90 °C EPR insulation, braid shield and EHD CPE jacket.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ICEA S-75-381 / NEMA WC 58 / MSHA across -40 to +90 °C.

EMC screen
Oil-resistant
Flame-retardant
Outdoor & humid
Order designation
Type SH 15 kV 1/C 4/0 AWG (100% EPR)
Outer Ø ≈
35.1 mm
Net weight ≈
1,980 kg/km
Tensile rating ≈
21.3 kN
Core / stranding
532-wire Class K SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
15 kV
5 kV / 8 kV / 15 kV / 25 kV / 35 kV
Operating temp.
-40 to +90 °C
Continuous mining & industrial duty
Min. bend radius
8 × OD
Fixed installation / dynamic routing
Core / conductor
1/C 2 AWG–750MCM
ASTM B172 Class K rope-lay tinned Cu
Outer protection
2-Layer EHD CPE
Extra-heavy-duty black crosslinked CPE
Standard
ICEA S-75-381
ICEA S-75-381 / NEMA WC 58 / MSHA

Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58 / MSHA — confirmed in the datasheet and quotation for your order.

Application fit

Is Type SH right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per ICEA S-75-381 / NEMA WC 58 / MSHA across -40 to +90 °C.

Trailing & towing

Suitable

Engineered for heavy-duty mobile mining and industrial trailing duty per ICEA S-75-381 / NEMA WC 58 / MSHA.

Mine roadway & tunnel wall hangers

Suitable

Suitable for underground coal/hard-rock roadways, shuttle cars and quarry feeders (-40 to +90 °C).

Fixed installation

Suitable

Can be installed on cable trays, hangers and mobile skid interconnections within 8 × OD.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: Type SH (ICEA S-75-381 / NEMA WC 58 / MSHA) featuring flexible conductor (1/c 4/0 awg), conductor stress shield (ess) and separator tape & ehd cpe jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible Conductor (1/C 4/0 AWG)Rope-lay stranded annealed tinned copper (ASTM B33 / B172 Class K)
2Conductor Stress Shield (ESS)Semiconductive tape + extruded thermosetting semiconductive layer
3MV Primary Insulation (90 °C EPR)High-dielectric ethylene propylene rubber (5.33 mm wall @ 15 kV)
4Insulation Screen & Composite BraidStrippable semicon layer + tinned copper & polyamide braid shield (≥60%)
5Separator Tape & EHD CPE JacketReinforcing separator tape + two-layer extra-heavy-duty black CPE jacket

Type SH — Standard Mining Execution

Built to ICEA S-75-381 / NEMA WC 58 / MSHA with flexible conductor (1/c 4/0 awg) and separator tape & ehd cpe jacket

Type SH — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

Type SH — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58 / MSHA. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
15 kV (ICEA S-75-381 / NEMA WC 58 / MSHA)
Core / conductor construction
Flexible Conductor (1/C 4/0 AWG) — Rope-lay stranded annealed tinned copper (ASTM B33 / B172 Class K)
Primary dielectric / buffering
Conductor Stress Shield (ESS) — Semiconductive tape + extruded thermosetting semiconductive layer

Thermal

Continuous operating temperature
-40 to +90 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per ICEA S-75-381 / NEMA WC 58 / MSHA
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Separator Tape & EHD CPE Jacket — Reinforcing separator tape + two-layer extra-heavy-duty black CPE jacket
Minimum bending radius
8 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per ICEA S-75-381 / NEMA WC 58 / MSHA

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per ICEA S-75-381 / NEMA WC 58 / MSHA
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per ICEA S-75-381 / NEMA WC 58 / MSHA
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ICEA S-75-381 / NEMA WC 58 / MSHA
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Type SH
Sheath colour & metre marking
Continuous metre-marked black mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Type SH mining & industrial configurations

Manufactured to ICEA S-75-381 / NEMA WC 58 / MSHA for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
Type SH Construction Schedule (-40 to +90 °C)
Type SH 15 kV 1/C 2/0 AWG (100% EPR)1 × 2/0 AWG (15 kV Shielded)329-wire Class K SnCu31.81,49013.4255
Type SH 15 kV 1/C 4/0 AWG (100% EPR)1 × 4/0 AWG (15 kV Shielded)532-wire Class K SnCu35.11,98021.3280
Type SH 15 kV 1/C 350 kcmil (100% EPR)1 × 350 kcmil (15 kV Shielded)882-wire Class K SnCu40.42,91035.3325
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per ICEA S-75-381 / NEMA WC 58 / MSHA.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (ICEA S-75-381 / NEMA WC 58 / MSHA)DC resistance at 20 °C / optical attenuation and outer diameter within ICEA S-75-381 / NEMA WC 58 / MSHA tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (ICEA S-75-381 / NEMA WC 58 / MSHA)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (ICEA S-75-381 / NEMA WC 58 / MSHA)Verified flame retardancy, mechanical integrity and thermal endurance across -40 to +90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ICEA S-75-381 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Type SH ICEA S-75-381 15 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Type SH (Type SH 5–35 kV MSHA Single-Conductor Shielded Power Cable)?
Type SH (Type SH 5–35 kV MSHA Single-Conductor Shielded Power Cable) is manufactured in accordance with ICEA S-75-381 / NEMA WC 58 / MSHA for 15 kV duty over -40 to +90 °C. Its 5-layer construction comprises Flexible Conductor (1/C 4/0 AWG), Conductor Stress Shield (ESS) and Separator Tape & EHD CPE Jacket.
What is the minimum bending radius and operating temperature range for Type SH?
The minimum bending radius for Type SH is 8 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of Type SH arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Conductor (1/C 4/0 AWG) (Rope-lay stranded annealed tinned copper (ASTM B33 / B172 Class K)); (02) Conductor Stress Shield (ESS) (Semiconductive tape + extruded thermosetting semiconductive layer); (03) MV Primary Insulation (90 °C EPR) (High-dielectric ethylene propylene rubber (5.33 mm wall @ 15 kV)); (04) Insulation Screen & Composite Braid (Strippable semicon layer + tinned copper & polyamide braid shield (≥60%)); (05) Separator Tape & EHD CPE Jacket (Reinforcing separator tape + two-layer extra-heavy-duty black CPE jacket).
What factory test certificates are supplied with Type SH?
Every production drum of Type SH undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per ICEA S-75-381 / NEMA WC 58 / MSHA, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Type SH

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Type SH 5–35 kV MSHA Single-Conductor Shielded Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote