Contact

SHD-GC LED 8–15 kV Illuminated TPU Mining Trailing CableICEA S-75-381 / NEMA WC 58 · 8–15 kV · -40 °C to +90 °C LED-lit optical-clarity TPU shovel cable

SHD-GC LED 8–15 kV LED-illuminated mining trailing cable combining three tinned copper MV EPR phase cores with copper braid shields, two grounds, one yellow XLPE ground-check core, internal red LED emitters every 1.2 m and a transparent TPU jacket.

EMC screen
Anti-torsion braid
Oil-resistant
Outdoor & humid
Order designation
SHD-GC LED 8 kV 3×1/0 AWG + 2×6 + 1×8 GC
Outer Ø ≈
58.4 mm
Weight ≈
5,120 kg/km
Tensile load ≈
38.0 kN
Core / stranding
Rope-lay tinned Cu + Cu braid + LED
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
8–15 kV
MV shovel & dragline trailing
Operating temp.
−40…+90 °C
Continuous thermal operating range
Min. bend radius
6–8 × OD
Installed / dynamic routing limit
Core / conductor
3/C + 2G + 1GC
Rope-lay tinned Cu + LED elements
Outer protection
Transparent TPU
Optical-clarity heavy TPU + braid
Standard
ICEA S-75-381
ICEA S-75-381 / NEMA WC 58

Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58 — confirmed in the datasheet and quotation for your order.

Application fit

Is SHD-GC LED right for your machine?

SHD-GC LED 8–15 kV LED-illuminated mining trailing cable combining three tinned copper MV EPR phase cores with copper braid shields, two grounds, one yellow XLPE ground-check core, internal red LED emitters every 1.2 m and a transparent TPU jacket.

Trailing & towing

Suitable

Internal red LED modules spaced every 1.2 m make the energized trailing cable unmistakable to haul-truck operators at night.

Mine roadway & tunnel wall hangers

Suitable

Optical-clarity heavy-duty TPU outer sheath resists rock abrasion, haul-road impact, diesel oil and sub-zero pit conditions.

Motorised monospiral reel

Suitable

Reinforcing braid and rope-lay tinned copper conductors handle mobile cable-reel boat and shovel payout tension.

Energy chain / drag chain

Not suitable

Large-diameter MV pit trailing cable; not intended for indoor factory energy chains.

PWR AFR PUR+LUM
Typical machinesMining & TunnellingOpen-Pit Electric Rope Shovels & Hydraulic ExcavatorsWalking Draglines, Pit Drills & Mobile CrushersNight-Shift Haul-Road Crossings & Pit SubstationsHigh-Altitude Copper, Gold, Iron & Coal Surface Mines

Construction

Layer by layer

Shown: SHD-GC LED (ICEA S-75-381 / NEMA WC 58) featuring mv phase cores (3xtinned cu), ground & ground-check cores and transparent tpu outer jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1MV Phase Cores (3xTinned Cu)Flexible rope-lay stranded tinned copper phase conductors with semiconductive screen, 8–15 kV EPR insulation, semicon, and tinned copper braid shieldICEA S-75-381 / NEMA WC 58
2Ground & Ground-Check CoresTwo uninsulated stranded tinned copper grounding conductors and one yellow XLPE-insulated ground-check pilot conductor in the intersticesICEA S-75-381 / NEMA WC 58
3Helical LED Illuminating UnitsIntegrated solid-state red LED illuminating strings helically laid with LED emitters spaced every 1.2 m for 360° haul-truck visibilityICEA S-75-381 / NEMA WC 58
4Transparent Bedding & BraidTransparent flexible PVC interstitial bedding, clear nylon separator tape, and an open-weave overall tinned copper reinforcement braidICEA S-75-381 / NEMA WC 58
5Transparent TPU Outer JacketOptical-clarity heavy-duty transparent thermoplastic polyurethane (TPU) outer jacket resistant to run-over, rock cut, and oilICEA S-75-381 / NEMA WC 58

SHD-GC LED — Standard Execution

Built to ICEA S-75-381 / NEMA WC 58 with mv phase cores (3xtinned cu) and transparent tpu outer jacket

SHD-GC LED — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

SHD-GC LED — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
8–15 kV (ICEA S-75-381 / NEMA WC 58)
Core / conductor construction
MV Phase Cores (3xTinned Cu) — Flexible rope-lay stranded tinned copper phase conductors with semiconductive screen, 8–15 kV EPR insulation, semicon, and tinned copper braid shield
Primary dielectric / insulation
Ground & Ground-Check Cores — Two uninsulated stranded tinned copper grounding conductors and one yellow XLPE-insulated ground-check pilot conductor in the interstices

Thermal

Continuous operating temperature
−40…+90 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
Transparent TPU Outer Jacket — Optical-clarity heavy-duty transparent thermoplastic polyurethane (TPU) outer jacket resistant to run-over, rock cut, and oil
Minimum bending radius
6–8 × OD
Structural layer count
5 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per ICEA S-75-381 / NEMA WC 58
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ICEA S-75-381 / NEMA WC 58
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SHD-GC LED
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

4 standard SHD-GC LED configurations

Manufactured to ICEA S-75-381 / NEMA WC 58 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
SHD-GC LED Construction Schedule (−40…+90 °C)
SHD-GC LED 8 kV 3×2 AWG + 2×8 + 1×8 GC3×2 AWG + 2×8 + 1×8 GC (8 kV)Rope-lay tinned Cu + Cu braid + LED52.83,95028.0320
SHD-GC LED 8 kV 3×1/0 AWG + 2×6 + 1×8 GC3×1/0 AWG + 2×6 + 1×8 GC (8 kV)Rope-lay tinned Cu + Cu braid + LED58.45,12038.0355
SHD-GC LED 15 kV 3×2 AWG + 2×8 + 1×8 GC3×2 AWG + 2×8 + 1×8 GC (15 kV)Rope-lay tinned Cu + Cu braid + LED60.24,68030.0365
SHD-GC LED 15 kV 3×2/0 AWG + 2×5 + 1×8 GC3×2/0 AWG + 2×5 + 1×8 GC (15 kV)Rope-lay tinned Cu + Cu braid + LED68.56,89046.0415
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per ICEA S-75-381 / NEMA WC 58.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (ICEA S-75-381 / NEMA WC 58)Electrical parameters and outer diameter within ICEA S-75-381 / NEMA WC 58 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (ICEA S-75-381 / NEMA WC 58)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (ICEA S-75-381 / NEMA WC 58)Verified structural and dielectric integrity across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ICEA S-75-381 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SHD-GC LED ICEA S-75-381 8–15 kV CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is SHD-GC LED engineered for?
SHD-GC LED 8–15 kV LED-illuminated mining trailing cable combining three tinned copper MV EPR phase cores with copper braid shields, two grounds, one yellow XLPE ground-check core, internal red LED emitters every 1.2 m and a transparent TPU jacket. It is built to ICEA S-75-381 / NEMA WC 58 for open-pit electric rope shovels & hydraulic excavators and walking draglines, pit drills & mobile crushers.
What are the minimum bending radius and operating temperature range for SHD-GC LED?
The minimum bending radius for SHD-GC LED is 6–8 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of SHD-GC LED arranged from inside to outside?
From inside to outside, the construction sequence is: (01) MV Phase Cores (3xTinned Cu) (Flexible rope-lay stranded tinned copper phase conductors with semiconductive screen, 8–15 kV EPR insulation, semicon, and tinned copper braid shield); (02) Ground & Ground-Check Cores (Two uninsulated stranded tinned copper grounding conductors and one yellow XLPE-insulated ground-check pilot conductor in the interstices); (03) Helical LED Illuminating Units (Integrated solid-state red LED illuminating strings helically laid with LED emitters spaced every 1.2 m for 360° haul-truck visibility); (04) Transparent Bedding & Braid (Transparent flexible PVC interstitial bedding, clear nylon separator tape, and an open-weave overall tinned copper reinforcement braid); (05) Transparent TPU Outer Jacket (Optical-clarity heavy-duty transparent thermoplastic polyurethane (TPU) outer jacket resistant to run-over, rock cut, and oil).
What factory test certificates are supplied with SHD-GC LED?
Every production drum of SHD-GC LED undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per ICEA S-75-381 / NEMA WC 58, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SHD-GC LED

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SHD-GC LED 8–15 kV Illuminated TPU Mining Trailing Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp