Trailing & towing
Internal red LED modules spaced every 1.2 m make the energized trailing cable unmistakable to haul-truck operators at night.
Product
SHD-GC LED 8–15 kV LED-illuminated mining trailing cable combining three tinned copper MV EPR phase cores with copper braid shields, two grounds, one yellow XLPE ground-check core, internal red LED emitters every 1.2 m and a transparent TPU jacket.
Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58 — confirmed in the datasheet and quotation for your order.
Application fit
SHD-GC LED 8–15 kV LED-illuminated mining trailing cable combining three tinned copper MV EPR phase cores with copper braid shields, two grounds, one yellow XLPE ground-check core, internal red LED emitters every 1.2 m and a transparent TPU jacket.
Internal red LED modules spaced every 1.2 m make the energized trailing cable unmistakable to haul-truck operators at night.
Optical-clarity heavy-duty TPU outer sheath resists rock abrasion, haul-road impact, diesel oil and sub-zero pit conditions.
Reinforcing braid and rope-lay tinned copper conductors handle mobile cable-reel boat and shovel payout tension.
Large-diameter MV pit trailing cable; not intended for indoor factory energy chains.
PWR AFR PUR+LUMConstruction
Shown: SHD-GC LED (ICEA S-75-381 / NEMA WC 58) featuring mv phase cores (3xtinned cu), ground & ground-check cores and transparent tpu outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | MV Phase Cores (3xTinned Cu) | Flexible rope-lay stranded tinned copper phase conductors with semiconductive screen, 8–15 kV EPR insulation, semicon, and tinned copper braid shieldICEA S-75-381 / NEMA WC 58 |
| 2 | Ground & Ground-Check Cores | Two uninsulated stranded tinned copper grounding conductors and one yellow XLPE-insulated ground-check pilot conductor in the intersticesICEA S-75-381 / NEMA WC 58 |
| 3 | Helical LED Illuminating Units | Integrated solid-state red LED illuminating strings helically laid with LED emitters spaced every 1.2 m for 360° haul-truck visibilityICEA S-75-381 / NEMA WC 58 |
| 4 | Transparent Bedding & Braid | Transparent flexible PVC interstitial bedding, clear nylon separator tape, and an open-weave overall tinned copper reinforcement braidICEA S-75-381 / NEMA WC 58 |
| 5 | Transparent TPU Outer Jacket | Optical-clarity heavy-duty transparent thermoplastic polyurethane (TPU) outer jacket resistant to run-over, rock cut, and oilICEA S-75-381 / NEMA WC 58 |
Built to ICEA S-75-381 / NEMA WC 58 with mv phase cores (3xtinned cu) and transparent tpu outer jacket
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to ICEA S-75-381 / NEMA WC 58 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SHD-GC LED Construction Schedule (−40…+90 °C) | |||||||
| SHD-GC LED 8 kV 3×2 AWG + 2×8 + 1×8 GC | 3×2 AWG + 2×8 + 1×8 GC (8 kV) | Rope-lay tinned Cu + Cu braid + LED | 52.8 | 3,950 | 28.0 | 320 | |
| SHD-GC LED 8 kV 3×1/0 AWG + 2×6 + 1×8 GC | 3×1/0 AWG + 2×6 + 1×8 GC (8 kV) | Rope-lay tinned Cu + Cu braid + LED | 58.4 | 5,120 | 38.0 | 355 | |
| SHD-GC LED 15 kV 3×2 AWG + 2×8 + 1×8 GC | 3×2 AWG + 2×8 + 1×8 GC (15 kV) | Rope-lay tinned Cu + Cu braid + LED | 60.2 | 4,680 | 30.0 | 365 | |
| SHD-GC LED 15 kV 3×2/0 AWG + 2×5 + 1×8 GC | 3×2/0 AWG + 2×5 + 1×8 GC (15 kV) | Rope-lay tinned Cu + Cu braid + LED | 68.5 | 6,890 | 46.0 | 415 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 3×2 AWG (8 kV SHD-GC LED) | 0.53 | 8 kV / 159 A + LED visual safety | −40…+90 °C |
| 3×1/0 AWG (8 kV SHD-GC LED) | 0.34 | 8 kV / 211 A + LED visual safety | −40…+90 °C |
| 3×2 AWG (15 kV SHD-GC LED) | 0.53 | 15 kV / 164 A + LED visual safety | −40…+90 °C |
| 3×2/0 AWG (15 kV SHD-GC LED) | 0.27 | 15 kV / 243 A + LED visual safety | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (ICEA S-75-381 / NEMA WC 58) | Electrical parameters and outer diameter within ICEA S-75-381 / NEMA WC 58 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (ICEA S-75-381 / NEMA WC 58) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (ICEA S-75-381 / NEMA WC 58) | Verified structural and dielectric integrity across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.