Contact
subsea ROV umbilical, AUV tether & sonar tow cableICEA S-75-381 / DNV-ST-E4023.6/6 kV (1.8/3 kV) (-40 to +90 °C)Subsea / Marine Outer Protective She

Heavy-Mining Subsea Mining & Trencher CableICEA S-75-381 / DNV-ST-E402 — 3.6/6 kV (1.8/3 kV) — -40 to +90 °C Subsea & Marine Cable

Heavy-Mining Subsea Mining & Trencher Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (ICEA S-75-381 / DNV-ST-E402, 3.6/6 kV (1.8/3 kV), -40 to +90 °C, min. bend radius 10 × OD).

Water-resistant
Oil-resistant
Outdoor & humid
Approved
Order designation
Heavy-Mining Subsea Trencher Cable Hybrid 4G2.5+
Outer Ø ≈
14.6 mm
Net weight ≈
285 kg/km
Max. pulling ≈
18.0 kN
Core / stranding
Class 5 SnCu + Aramid Braid + Subsea PUR
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
3.6/6 kV (1.8/3
Tested per ICEA S-75-381 / DNV-ST-E402
Operating temp.
−40…+90 °C
Subsea, deck & cold-water duty
Min. bend radius
10 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Single-Mode / Mu
Hermetic stainless-steel tube / tight-bu
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
ICEA S-75-381 /
ICEA S-75-381 & DNV Heavy-Mining Subsea

Typical values for this cable type, based on ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Heavy-Mining Subsea Trencher Cable right for your machine?

Heavy-Mining Subsea Mining & Trencher Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (ICEA S-75-381 / DNV-ST-E402, 3.6/6 kV (1.8/3 kV), -40 to +90 °C, min. bend radius 10 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers

Vertical / spreader reel

Suitable

Contra-helical galvanized steel wire armour or high-modulus aramid/LCP braid supports vertical traction winches, TMS cages and tow sheaves

Free-hanging vertical run

Suitable

Torque-balanced armour or neutrally buoyant foamed-PUR jacket prevents hockling and kinking during free-swimming ROV and tether excursions

Offshore platform & shipboard deck trays

Suitable

Resists seawater, marine bio-fouling, hydraulic oil, UV radiation and abrasion across vessel A-frames and launch-and-recovery systems (LAR

Energy chain / drag chain

Not suitable

Subsea ROV umbilicals and tow cables are optimized for winch deployment and water-column catenaries rather than high-speed factory drag ch

Use Drag-Chain Feeder Cable
Typical machinesUnderwater & Ocean ExplorationWork-Class & Observation ROV Umbilicals and TMS TethersOffshore Aquaculture Net Cleaners & Subsea Cage InspectionAUV, Ocean Glider & Expendable Spool-Payoff Micro-TethersUSV Towed Sonar Arrays, Seabed Crawlers & Subsea Trenchers

Construction

Layer by layer

Shown: Heavy-Mining Subsea Trencher Cable (ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (3-layer construction).

Heavy-Mining Subsea Trencher Cable — stepped horizontal cutaway showing Single-Mode / Multi-Mode Optical Unit and Subs
Layer cutaway
#LayerMaterial & reference
1Single-Mode / Multi-Mode Optical UnitHermetic stainless-steel tube / tight-buffered optical unit
2Power & Control Copper ConductorsStranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation
3Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

Heavy-Mining Subsea Trencher Cable — Standard Subsea & Marine Execution

Built to ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification with single-mode / multi-mode optical unit and subsea / marine outer protective sheath

Heavy-Mining Subsea Trencher Cable — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

Heavy-Mining Subsea Trencher Cable — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
3.6/6 kV (1.8/3 kV) (ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification)
Core / conductor construction
Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit
Primary dielectric / optical buffer
Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation

Thermal

Continuous operating temperature
−40…+90 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+90 °C per ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
10 × OD
Reinforcement / screen / bedding layer
Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Heavy-Mining Subsea Trencher Cable
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Heavy-Mining Subsea Trencher Cable configurations

Manufactured to ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Heavy-Mining Subsea Trencher Cable Construction Schedule (−40…+90 °C)
Heavy-Mining Subsea Trencher Cable Hybrid 4G2.5+4G2.5 mm² Power + 4×SM + 2×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR14.628518.090
Heavy-Mining Subsea Trencher Cable Hybrid 4G6+FO4G6.0 mm² Power + 4×SM/MM + 4×2×0.5Class 5 SnCu + Aramid Braid + Subsea PUR19.254032.0120
Heavy-Mining Subsea Trencher Cable Hybrid 4G16+F4G16 mm² Power + 8×SM/MM + 4×2×0.75Class 5 SnCu + Heavy Aramid + Subsea PUR26.51,12055.0165
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification)DC resistance at 20 °C, optical attenuation and wall thickness within ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification)Zero dielectric breakdown and verified wet insulation resistance for 3.6/6 kV (1.8/3 kV) ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ICEA S-75-381 / DNV-ST-E402 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Heavy-Mining Subsea Trencher Cable ICEA S-75-381 / DNV-ST-E402 3.6/6 kV (1.8/3 kV) CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Heavy-Mining Subsea Trencher Cable (Heavy-Mining Subsea Mining & Trencher Cable)?
Heavy-Mining Subsea Trencher Cable (Heavy-Mining Subsea Mining & Trencher Cable) is manufactured in accordance with ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification for 3.6/6 kV (1.8/3 kV) subsea,ROV and marine aquaculture service over -40 to +90 °C. Its 3-layer construction comprises single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for Heavy-Mining Subsea Trencher Cable?
The minimum bending radius for Heavy-Mining Subsea Trencher Cable is 10 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of Heavy-Mining Subsea Trencher Cable arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit; (02) Power & Control Copper Conductors — Stranded copper conductors with Ethylene-propylene rubber (EPR/EPDM) insulation; (03) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with Heavy-Mining Subsea Trencher Cable?
Every production drum of Heavy-Mining Subsea Trencher Cable undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per ICEA S-75-381 & DNV Heavy-Mining Subsea Trencher Electro-Optical Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Heavy-Mining Subsea Trencher Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Heavy-Mining Subsea Mining & Trencher Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp