EMC-shielded wind turbine converter & VFD drive cableUL 2277 WTTC / UL 44 RHW-21,000 V WTTC / 2,000 V RHW-2 (-40 toCold & Sunlight-Resistant Heavy Poly

Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD CableUL 2277 WTTC / UL 44 RHW-2 — 1,000 V WTTC / 2,000 V RHW-2 — -40 to +90 °C Wind Turbine Cable

Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD Cable (UL 2277 WTTC / UL 44 RHW-2, 1,000 V WTTC / 2,000 V RHW-2, -40 to +90 °C, min. bend radius 8 × OD).

Anti-torsion braid
EMC screen
Oil-resistant
Approved
Order designation
Symmetrical-Ground 1kV WTTC 4G16 / 3×16+3G2.5
Outer Ø ≈
21.8 mm
Net weight ≈
790 kg/km
Max. pulling ≈
9.5 kN
Core / stranding
IEC 60228 Class 5 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1,000 V WTTC / 2
Tested per UL 2277 WTTC / UL 44 RHW-2
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
8 × OD
Drip-loop, hub & tower routing
Core / conductor
XHHW-2 / RHW-2 P
Flexible stranded copper phase cores (14
Outer protection
Cold & Sunlight-
UL WTTC 1,000 V & RHW-2 2,000 V wind con
Standard
UL 2277 WTTC / U
UL Subject 2277 WTTC 1,000 V & UL 44 RHW

Typical values for this cable type, based on UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is Symmetrical-Ground 1kV WTTC / 2kV VFD right for your machine?

Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD Cable (UL 2277 WTTC / UL 44 RHW-2, 1,000 V WTTC / 2,000 V RHW-2, -40 to +90 °C, min. bend radius 8 × OD).

VFD inverter to AC motor screened feeder

Suitable

Symmetrical 3+3 split grounds or 100% foil + 85% tinned copper braid shield give a low-impedance return path for PWM drive currents.

Motor stator, traction & converter leads

Suitable

Extra-thick 2XL XLPE / RHW-2 insulation withstands high dV/dt voltage spikes and corona discharge from IGBT wind converters.

Free-hanging vertical run

Suitable

Class 5 / Class K flexible copper conductors and −40 °C TPE/CPE/PVC jackets handle nacelle vibration, tray routing and drip-loop torsion.

Fixed installation

Suitable

Dual-listed to UL Subject 2277 Type WTTC (1,000 V), UL 1277 TC-ER (600 V) and UL 44 RHW-2 (2,000 V) for raceway-free nacelle installation.

Motorised monospiral reel

Not suitable

Wind converter VFD feeder cable is not designed for continuous mobile reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingWind Turbine Main Power Converter & Generator DrivesElectric Yaw Drive & Blade Pitch Servo VFD MotorsNacelle Hydraulic Pump, Cooling Fan & Auxiliary VFDsUL 2277 WTTC 1,000 V & 2,000 V Renewable Drive Systems

Construction

Layer by layer

Shown: Symmetrical-Ground 1kV WTTC / 2kV VFD (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification) featuring xhhw-2 / rhw-2 phase conductors (3 cores), symmetrical tri-sectional grounds (3 cores) and cold & sunlight-resistant heavy polymer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1XHHW-2 / RHW-2 Phase Conductors (3 CoresFlexible stranded copper phase cores (14 AWG to 500 kcmil)
2Symmetrical Tri-Sectional Grounds (3 CorThree balanced interstitial ground cores canceling common-mode voltage
3Dual Helical Copper Tape EMC Shield (100Two overlapping copper tapes providing low-impedance EMI return path
4Cold & Sunlight-Resistant Heavy Polymer UL WTTC 1,000 V & RHW-2 2,000 V wind converter drive sheath

Symmetrical-Ground 1kV WTTC / 2kV VFD — Standard Wind Turbine Execution

Built to UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification with xhhw-2 / rhw-2 phase conductors (3 cores) and cold & sunlight-resistant heavy polymer jacket

Symmetrical-Ground 1kV WTTC / 2kV VFD — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

Symmetrical-Ground 1kV WTTC / 2kV VFD — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1,000 V WTTC / 2,000 V RHW-2 (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification)
Core / conductor construction
XHHW-2 / RHW-2 Phase Conductors (3 Cores) — Flexible stranded copper phase cores (14 AWG to 500 kcmil)
Primary dielectric / insulation
Symmetrical Tri-Sectional Grounds (3 Cores) — Three balanced interstitial ground cores canceling common-mode voltage

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Cold & Sunlight-Resistant Heavy Polymer Jacket — UL WTTC 1,000 V & RHW-2 2,000 V wind converter drive sheath
Minimum bending radius
8 × OD
Intermediate screen / separator / core layer
Dual Helical Copper Tape EMC Shield (100%) — Two overlapping copper tapes providing low-impedance EMI return path

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Symmetrical-Ground 1kV WTTC / 2kV VFD
Sheath colour & metre marking
Continuous metre-marked black outer finish (Cold & Sunlight-)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard Symmetrical-Ground 1kV WTTC / 2kV VFD wind turbine configurations

Manufactured to UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Symmetrical-Ground 1kV WTTC / 2kV VFD Construction Schedule (−40…+90 °C)
Symmetrical-Ground 1kV WTTC 4G16 / 3×16+3G2.54G16 mm² (or 3×6 AWG + 3G10 AWG)IEC 60228 Class 5 / Class K Cu21.87909.5130
Symmetrical-Ground 1kV WTTC 4G50 / 3×50+3G104G50 mm² (or 3×1 AWG + 3G6 AWG)IEC 60228 Class 5 / Class K Cu31.42,14022.5190
Symmetrical-Ground 1kV WTTC 3×150+3G25 VFD3×150 + 3G25 mm² (or 3×350 kcmil)IEC 60228 Class 5 / Class K Cu47.25,48058.0285
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification)DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification)Zero dielectric breakdown and verified insulation resistance for 1,000 V WTTC / 2,000 V RHW-2 ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 2277 WTTC / UL 44 RHW-2 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Symmetrical-Ground 1kV WTTC / 2kV VFD UL 2277 WTTC / UL 44 RHW-2 1,000 V WTTC / 2,000 V RHW-2 CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Symmetrical-Ground 1kV WTTC / 2kV VFD (Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD Cable)?
Symmetrical-Ground 1kV WTTC / 2kV VFD (Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD Cable) is manufactured in accordance with UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification for 1,000 V WTTC / 2,000 V RHW-2 wind turbine service over -40 to +90 °C. Its 4-layer construction comprises xhhw-2 / rhw-2 phase conductors (3 cores), symmetrical tri-sectional grounds (3 cores) and cold & sunlight-resistant heavy polymer jacket.
What is the minimum bending radius and operating temperature range for Symmetrical-Ground 1kV WTTC / 2kV VFD?
The minimum bending radius for Symmetrical-Ground 1kV WTTC / 2kV VFD is 8 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of Symmetrical-Ground 1kV WTTC / 2kV VFD arranged from inside to outside?
From inside to outside, the construction sequence is: (01) XHHW-2 / RHW-2 Phase Conductors (3 Cores) — Flexible stranded copper phase cores (14 AWG to 500 kcmil); (02) Symmetrical Tri-Sectional Grounds (3 Cores) — Three balanced interstitial ground cores canceling common-mode voltage; (03) Dual Helical Copper Tape EMC Shield (100%) — Two overlapping copper tapes providing low-impedance EMI return path; (04) Cold & Sunlight-Resistant Heavy Polymer Jacket — UL WTTC 1,000 V & RHW-2 2,000 V wind converter drive sheath.
What factory test certificates are supplied with Symmetrical-Ground 1kV WTTC / 2kV VFD?
Every production drum of Symmetrical-Ground 1kV WTTC / 2kV VFD undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Symmetrical 3+3 Dual Cu-Tape VFD Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Symmetrical-Ground 1kV WTTC / 2kV VFD

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Symmetrical-Ground 1kV WTTC / 2kV VFD Symmetrical-Ground 1,000 V UL WTTC / 2,000 V UL RHW-2 (3 Phase + 3 Split Grounds) Dual Copper-Tape Wind VFD Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote