Trailing & towing
Central extensible ground-check core sits on the neutral bending axis to eliminate pilot-wire breakage during trailing.
Product
TYPE G-CGC 2000 V unshielded mining trailing cable combining a central extensible yellow PP ground-check conductor, three rope-lay tinned copper EPR phase conductors, three symmetrical green grounds and a two-layer reinforced black CPE jacket.
Typical values for this cable type, based on ICEA S-75-381 / NEMA WC 58 — confirmed in the datasheet and quotation for your order.
Application fit
TYPE G-CGC 2000 V unshielded mining trailing cable combining a central extensible yellow PP ground-check conductor, three rope-lay tinned copper EPR phase conductors, three symmetrical green grounds and a two-layer reinforced black CPE jacket.
Central extensible ground-check core sits on the neutral bending axis to eliminate pilot-wire breakage during trailing.
Three symmetrical interstitial grounds provide balanced low-impedance fault return and balanced roundness.
Two-layer reinforced CPE jacket with embedded cord braid resists shuttle-car sheave tension and run-over.
Heavy-wall mining trailing cable; not intended for compact factory automation drag chains.
PWR AFR PUR+LUMConstruction
Shown: TYPE G-CGC (ICEA S-75-381 / NEMA WC 58) featuring central extensible ground-check, phase conductors (3xtinned cu) and two-layer reinforced cpe jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Central Extensible Ground-Check | Stretch-resistant stranded tinned copper ground-check conductor insulated with high-strength yellow polypropylene positioned at the neutral center axisICEA S-75-381 / NEMA WC 58 |
| 2 | Phase Conductors (3xTinned Cu) | Three flexible rope-lay stranded annealed tinned copper phase conductors with heavy-duty 2000 V EPR insulation (Black, White, Red)ICEA S-75-381 / NEMA WC 58 |
| 3 | Three Symmetrical Grounds | Three green-insulated/identified stranded tinned copper grounding conductors symmetrically laid in the outer valleys for balanced ground impedanceICEA S-75-381 / NEMA WC 58 |
| 4 | Two-Layer Reinforced CPE Jacket | Extra-heavy-duty two-layer black thermoset chlorinated polyethylene (CPE) jacket reinforced with an embedded high-tenacity textile cord braidICEA S-75-381 / NEMA WC 58 |
Built to ICEA S-75-381 / NEMA WC 58 with central extensible ground-check and two-layer reinforced cpe jacket
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to ICEA S-75-381 / NEMA WC 58 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TYPE G-CGC Construction Schedule (−40…+90 °C) | |||||||
| TYPE G-CGC 2000 V 3×4 AWG + 3×8G + 1×10 GC | 3×4 AWG + 3×8 AWG G + 1×10 GC | Rope-lay tinned Cu + reinforced CPE | 32.5 | 1,590 | 14.5 | 195 | |
| TYPE G-CGC 2000 V 3×2 AWG + 3×7G + 1×10 GC | 3×2 AWG + 3×7 AWG G + 1×10 GC | Rope-lay tinned Cu + reinforced CPE | 36.8 | 2,180 | 21.0 | 220 | |
| TYPE G-CGC 2000 V 3×1/0 AWG + 3×5G + 1×8 GC | 3×1/0 AWG + 3×5 AWG G + 1×8 GC | Rope-lay tinned Cu + reinforced CPE | 44.2 | 3,290 | 33.0 | 265 | |
| TYPE G-CGC 2000 V 3×2/0 AWG + 3×4G + 1×8 GC | 3×2/0 AWG + 3×4 AWG G + 1×8 GC | Rope-lay tinned Cu + reinforced CPE | 48.0 | 3,980 | 41.5 | 290 | |
| TYPE G-CGC 2000 V 3×4/0 AWG + 3×2G + 1×8 GC | 3×4/0 AWG + 3×2 AWG G + 1×8 GC | Rope-lay tinned Cu + reinforced CPE | 55.4 | 5,640 | 62.0 | 335 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 3×4 AWG + 3×8G + 1×10 GC | 0.85 | 2000 V / 122 A | −40…+90 °C |
| 3×2 AWG + 3×7G + 1×10 GC | 0.53 | 2000 V / 159 A | −40…+90 °C |
| 3×1/0 AWG + 3×5G + 1×8 GC | 0.34 | 2000 V / 211 A | −40…+90 °C |
| 3×2/0 AWG + 3×4G + 1×8 GC | 0.27 | 2000 V / 243 A | −40…+90 °C |
| 3×4/0 AWG + 3×2G + 1×8 GC | 0.17 | 2000 V / 321 A | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (ICEA S-75-381 / NEMA WC 58) | Electrical parameters and outer diameter within ICEA S-75-381 / NEMA WC 58 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (ICEA S-75-381 / NEMA WC 58) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (ICEA S-75-381 / NEMA WC 58) | Verified structural and dielectric integrity across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.