Contact

JE-H(St)H FE180/E30 Bd 225V VDE 0815 Fire-ResistantJE-H(St)H FE180/E30 Bd 225V VDE 0815 Fire-Resistant manufactured to DIN VDE 0815 / DIN 4102-12 E30, rated 225 V and -25°C to +90°C with a 10 × OD minimum bending radius for oil, gas & petrochemical installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
JE-H(St)H FE180/E30 Bd 225V VDE 0815 (2×2×0.8 mm)
Outer diameter
9.3 mm
Cable weight
203 kg/km
Min. bend radius
93 mm
Conductor & shield
Class 1 Solid Tinned Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
225 V
DIN VDE 0815 / DIN 4102-12 E30
Temperature
-25°C to +90°C
Fixed / flex duty
Min. bend radius
10 × OD
9.3–12.8 mm
Screening
Al/PET Foil
100% foil + tinned drain wire
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per DIN VDE 0815 / DIN 4102-12 E30 (JE-H(St)H FE180/E30 Bd 225V VDE 0815) — confirmed in the datasheet and quotation for your order.

Application fit

Is JE-H(St)H FE180/E30 Bd 225V VDE 0815 right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Emergency fire-survival riser circuit

Suitable

Circuit-integrity 225 V LSZH design sustains emergency alarms, smoke extraction, and evacuation lighting during fire exposure.

Typical machinesOil & Gas CablePower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

JE-H(St)H FE180/E30 Bd 225V VDE 0815 – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor4×2×0.8 mm Class 1 Solid Tinned Cu
2Insulation & Core IdentificationFE180/E30 circuit-integrity halogen-free FRNC insulation (0.8 mm Solid TC)
3Screen / Bedding / Armour LayerLSZH filler + 100% Plastic-Coated Aluminium Foil screen + drain wire
4Outer Protective SheathOrange FE180/E30 flame-retardant non-corrosive (FRNC/LSZH) outer sheath (OD 9.3 mm)

2×2×0.8 mm

Class 1 Solid Tinned Copper · Outer diameter 9.3 mm

4×2×0.8 mm

Class 1 Solid Tinned Copper · Outer diameter 11.0 mm

8×2×0.8 mm

Class 1 Solid Tinned Copper · Outer diameter 12.8 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per DIN VDE 0815 / DIN 4102-12 E30 (JE-H(St)H FE180/E30 Bd 225V VDE 0815). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
225 V
Conductor & core insulation
4×2×0.8 mm Class 1 Solid Tinned Cu · FE180/E30 circuit-integrity halogen-free FRNC insulation (0.8 mm Solid TC)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +90°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
DIN VDE 0815 / DIN 4102-12 E30

Mechanical

Minimum bending radius
10 × OD
Screening / armour architecture
LSZH filler + 100% Plastic-Coated Aluminium Foil screen + drain wire
Outer sheath material & colour
Orange FE180/E30 flame-retardant non-corrosive (FRNC/LSZH) outer sheath (OD 9.3 mm)

Reference standards

Reference standard
DIN VDE 0815 / DIN 4102-12 E30
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
JE-H(St)H FE180/E30 Bd 225V VDE 0815
2×2×0.8 mmClass 1 Solid Tinned CopperFE180/E30 circuit-integrity halogen-free FRNC insulationLSZH Jacket9.39335.98105.62034 AJE-H(St)H FE180/E30 Bd 225V VDE 0815 (2×2×0.8 mm)
4×2×0.8 mmClass 1 Solid Tinned CopperFE180/E30 circuit-integrity halogen-free FRNC insulationLSZH Jacket11.011035.98147.22834 AJE-H(St)H FE180/E30 Bd 225V VDE 0815 (4×2×0.8 mm)
8×2×0.8 mmClass 1 Solid Tinned CopperFE180/E30 circuit-integrity halogen-free FRNC insulationLSZH Jacket12.812835.98201.23874 AJE-H(St)H FE180/E30 Bd 225V VDE 0815 (8×2×0.8 mm)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0815 / DIN 4102-12 E30 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

JE-H(ST)H FE180/E30 BD 225V VDE 0815 FIRE-RESISTANT / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is JE-H(St)H FE180/E30 Bd 225V VDE 0815 designed for?
JE-H(St)H FE180/E30 Bd 225V VDE 0815 is engineered for oil, gas & petrochemical installations under DIN VDE 0815 / DIN 4102-12 E30, operating over -25°C to +90°C with a minimum bending radius of 10 × OD.
How is JE-H(St)H FE180/E30 Bd 225V VDE 0815 constructed across its layers?
Its 4-layer architecture combines 4×2×0.8 mm Class 1 Solid Tinned Cu with FE180/E30 circuit-integrity halogen-free FRNC insulation (0.8 mm Solid TC), LSZH filler + 100% Plastic-Coated Aluminium Foil screen + drain wire and Orange FE180/E30 flame-retardant non-corrosive (FRNC/LSZH) outer sheath (OD 9.3 mm).
What standards and routine factory tests apply to JE-H(St)H FE180/E30 Bd 225V VDE 0815?
Every manufactured drum is tested to DIN VDE 0815 / DIN 4102-12 E30 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for JE-H(St)H FE180/E30 Bd 225V VDE 0815?
Representative sizes include 2×2×0.8 mm, 4×2×0.8 mm and 8×2×0.8 mm, supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for JE-H(St)H FE180/E30 Bd 225V VDE 0815

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

JE-H(St)H FE180/E30 Bd 225V VDE 0815 Fire-Resistant

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote