NSSHÖU & H07RN8-F Rubber Cable FAT Testing & PO Checklist

Use our 8-point Purchase Order (PO) checklist and Factory Acceptance Test (FAT) guide for NSSHÖU (DIN VDE 0250-812) and H07RN8-F (EN 50525-2-21) rubber cables.

TEBAOFLEX JyenJiangsu Tebaoflex Special Cable Co., Ltd11 min read
NSSHÖU & H07RN8-F Rubber Cable FAT Testing & PO Checklist
Featured product
Browse All Cables
Category
Technical article
Updated
Reading time
11 min read
In this article13 sections
  1. 01FAT at a Glance: Routine & Type Test FAT Thresholds Across Heavy-Duty Rubber Cables
  2. 02Why Generic Mill Certificates Fail to Catch Counterfeit "Heavy-Duty" Rubber Cables
  3. 03Core Engineering Definitions for Rubber Cable FAT & Quality Control
  4. 04Inside TEBAOFLEX's 4-Stage Factory Acceptance Test (FAT) Protocol
  5. 05Copy-and-Paste 8-Point Engineering Purchase Order (PO) Checklist
  6. 06Key Takeaways & Frequently Asked Questions (FAQ)
  7. 07Key Engineering Takeaways for Rubber Cable Procurement
  8. 08Frequently Asked Questions (FAQ)
  9. 09How can a buyer verify that an NSSHÖU cable uses genuine 5GM5 polychloroprene instead of cheap SBR or thermoplastic rubber?
  10. 10What routine AC voltage test is required before shipping NSSHÖU, NSGAFÖU, and H07RN8-F drums?
  11. 11Why must the PO explicitly specify Class 5 tinned copper for NSSHÖU and NSGAFÖU?
  12. 12What FAT check confirms that NSSHKCGEÖU will trip a mine ground-fault relay reliably?
  13. 13Request a Sample FAT Dossier or a Custom Quote

By TEBAOFLEX Jyen, Senior Cable Application Specialist at TEBAOFLEX. Reviewed by the TEBAOFLEX Engineering Review Board. Updated on October 23, 2026.

TL;DR: Writing "NSSHÖU 4G35" or "H07RN8-F 4G16" on a Purchase Order (PO) without binding elastomer and electrical acceptance clauses leaves procurement teams vulnerable to three common supplier shortcuts: under-cured rubber that splits on rock (failing IEC 60811-507 Hot-Set), single-layer extrusion omitting the GM1b inner sheath, and high-water-uptake EM2 sold as AD8 submersible cable. Enforce our 8-Point Engineering PO Checklist to mandate IEC 60228 Class 5 tinned copper, 200 °C Hot-Set elongation max. 60% (TEBAOFLEX Lab, 2026), 5GM5 tear resistance >= 15.0 N/mm (18.5 N/mm measured), 100 °C IRM 902 oil tensile retention >= 90%, and 2.5 kV / 3.0 kV / 6.0 kV AC water-tank hipot testing across NSSHÖU Heavy-Duty Rubber Cable, NSSHKCGEÖU Screened Cable, NSGAFÖU 1.8/3 kV Cable, and H07RN8-F Submersible Rubber Cable.

FAT at a Glance: Routine & Type Test FAT Thresholds Across Heavy-Duty Rubber Cables

This procurement and quality-assurance guide provides a ready-to-use 8-Point PO Specification Checklist and documents TEBAOFLEX's 2026 Factory Acceptance Test (FAT) batch data across our Heavy-Duty Rubber Cable Range.

FAT Test Category & Standard.

Flagship Product Pages.

1. Conductor DC Resistance.

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: IEC 60228 Class 5 tinned Cu at 20 °C.
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: IEC 60228 Class 5 tinned Cu at 20 °C.
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: IEC 60228 Class 5 bare/tinned Cu at 20 °C.

2. Routine AC Water Hipot.

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: 3.0 kV AC for 5 min (0.6/1 kV).
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: 6.0 kV AC (1.8/3 kV) / 11.0 kV (3.6/6 kV).
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: 2.5 kV AC (H07RN8-F) / 3.0 kV (S1BC4N8-F).

3. Hot-Set Cure (200°C, 20 N/cm²).

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: max. 100% load / max. 25% set (58.4% / 9.2% FAT).
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: max. 100% load / max. 25% set (56.0% / 8.5% FAT).
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: max. 100% load / max. 25% set (61.2% / 10.4% FAT).

4. Sheath Tear (VDE 0472-613).

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: >= 15.0 N/mm (5GM5; 18.5 N/mm FAT).
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: >= 8.0 N/mm (5GM2; 10.2 N/mm FAT).
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: >= 7.5 N/mm (AD8 EM2; 10.4 N/mm FAT).

5. 100°C IRM 902 Oil Soak.

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: >= 70% tensile kept (91.2% FAT, 168 h).
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: >= 70% tensile kept (88.5% FAT, 168 h).
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: >= 65% tensile kept (86.0% FAT, 168 h).

6. Special Duty Verification.

  • NSSHÖU / NSSHKCGEÖU (DIN VDE 0250-812).: CGE screen under 500 Ohm.m (NSSHKCGEÖU).
  • NSGAFÖU / NSGAFCMÖU (DIN VDE 0250-602).: Short-circuit-proof wall (VDE 0100-520).
  • H07RN8-F / S1BC4N8-F (EN 50525-2-21 AD8).: 70 °C water uptake max. 10 mg/cm² (6.4 mg/cm² FAT).
Official TEBAOFLEX CAD cross-section comparison across NSSHÖU, NSSHKCGEÖU, NSGAFÖU, and H07RN8-F FAT-verified rubber cables.

View full-size illustration

Why Generic Mill Certificates Fail to Catch Counterfeit "Heavy-Duty" Rubber Cables

When an EPC contractor or mine maintenance department sources 0.6/1 kV NSSHÖU or AD8 H07RN8-F solely by lowest price per meter, unverified suppliers frequently cut production costs in three invisible ways. A basic continuity and room-temperature megger check will never detect these shortcuts:

  1. Speeding Up the CV Steam Line (Under-Vulcanization): Crosslinking 3GI3 EPR and 5GM5 polychloroprene requires precise residence time at 18 bar steam pressure (205 °C) inside a catenary continuous vulcanization (CCV) tube. Running the line 35% faster leaves 40% of the polymer chains un-crosslinked. The cable passes a room-temperature 1,000 V megger test in the factory, but splits open under rock compression or melts during a motor starting surge.
  2. Omitting the GM1b Inner Sheath on NSSHÖU: True DIN VDE 0250-812 NSSHÖU requires a two-layer jacket (GM1b inner sheath + 5GM5 outer sheath). Low-cost imitations extrude a single thick black or yellow jacket directly over the cores, reducing radial crush strength by 46% (from 24.6 kN down to 13.2 kN, TEBAOFLEX Lab, 2026).
  3. Blending Recycled SBR or Calcium Carbonate Into 5GM5 / AD8 Jackets: Diluting polychloroprene with styrene-butadiene (SBR) or cheap chalk fillers causes the sheath to fail 100 °C IRM 902 oil immersion (retaining under 50% tensile strength) and absorb > 22 mg/cm² of water in submersible pump wells.

In our third-party witness inspections of 27 field-failed rubber cable lots submitted by mining and dewatering clients in 2025 and 2026, 85% (23 of 27 lots, TEBAOFLEX Lab, 2026) failed the IEC 60811-507 200 °C Hot-Set vulcanization test (stretching > 160% or snapping completely within 3 minutes). Requiring a signed Hot-Set and DIN VDE 0472-613 tear-strength test report prior to dispatch catches 100% of under-cured or thermoplastic-adulterated rubber cables before they leave the factory port.

Core Engineering Definitions for Rubber Cable FAT & Quality Control

To help procurement engineers write legally and technically binding inspection clauses into tender documents, we define four essential FAT verification terms below:

  • IEC 60811-507 Hot-Set crosslink test is the mandatory factory acceptance test for thermoset rubber insulation (3GI3 / EI4) and sheathing (5GM5 / 5GM2 / EM2 / HM3). A stripped dumbbell sample is weighted at 20 N/cm² inside a 200 °C oven for 15 minutes to prove complete three-dimensional covalent vulcanization (elongation max. 100% under load, max. 25% permanent set).
  • DIN VDE 0472-613 trouser tear test is the mechanical test (paired with IEC 60811-506) that measures the force required (in N/mm of thickness) to propagate a longitudinal razor slit through an elastomer outer sheath. DIN VDE 0250-812 mandates >= 15.0 N/mm for 5GM5 heavy-duty mining sheaths.
  • Submerged water-tank AC dielectric test is the 100% routine factory hipot test (EN 50395 / DIN VDE 0472-502) where every completed cable reel is immersed in a heated water bath for >= 2 hours. It is then subjected to 2.5 kV AC (450/750 V), 3.0 kV AC (0.6/1 kV), or 6.0 kV AC (1.8/3 kV) for 5 minutes with zero breakdown.
  • Optical profile projector wall check is the cross-sectional dimensional audit (IEC 60811-201 / -202) that measures minimum radial point thickness (tₘᵢₙ) and concentricity of the 3GI3 core insulation, GM1b inner bedding, and 5GM5 outer sheath under 20x digital magnification.
Official TEBAOFLEX NSSHÖU Heavy-Duty Rubber Cable construction specification showing the verifiable Class 5 tinned copper, 3GI3 EPR, GM1b inner sheath, and 5GM5 outer sheath layers.

View full-size illustration

Inside TEBAOFLEX's 4-Stage Factory Acceptance Test (FAT) Protocol

Every production drum of NSSHÖU, NSSHKCGEÖU, NSHXÖU, NSGAFÖU, and H07RN8-F must clear four laboratory gates before our quality department issues the serialized Drum Release Certificate:

Official TEBAOFLEX NSHXÖU Halogen-Free Heavy-Duty Rubber Cable construction specification showing Class 5 copper, 3GI3 EPR insulation, and HM3 LSZH outer sheath.

View full-size illustration

  1. Gate A: Kelvin Bridge Conductor DC Resistance & Tinning Strip Check. We measure 20 °C temperature-corrected DC conductor resistance on 100% of drums using a four-terminal Kelvin micro-ohmmeter (verifying compliance with IEC 60228 Class 5 ceilings, e.g., max. 0.565 Ohm/km on 35 mm² tinned copper). For example, we also strip 100 mm of 3GI3 insulation to confirm bright, un-tarnished tin plating (ASTM B33 / IEC 60228).
  2. Gate B: Optical Wall Thickness & GM1b + 5GM5 Dual-Extrusion Audit. A 2 mm wafer from both drum ends is scanned on our digital profile projector. For instance, this verifies that minimum insulation thickness never falls below 0.90 x nominal - 0.1 mm and that the GM1b inner sheath fully fills all core interstices.
  3. Gate C: Elastomer Hot-Set (200 °C), Tear (VDE 0472-613), and Oil Soak (100 °C IRM 902). Dumbbell specimens cut from the actual drum sheath are tested for 200 °C Hot-Set (58.4% mean load elongation), trouser tear resistance (18.5 N/mm on 5GM5), and 168-hour 100 °C IRM 902 mineral oil tensile retention (91.2% on 5GM5, TEBAOFLEX Lab, 2026).
  4. Gate D: Water-Tank AC Hipot & Submersible Autoclave Cycling. Every drum passes a 5-minute submerged AC hipot test (3.0 kV for NSSHÖU, 6.0 kV for NSGAFÖU, 2.5 kV for H07RN8-F). Meanwhile, AD8 submersible lots undergo 10 bar hydrostatic autoclave cycling and 70 °C gravimetric water-uptake checks (max. 6.4 mg/cm²).
Tensile Retention After 168h IRM 902 Oil Soak at 100°C (%)

View full-size oil-retention chart

Tensile Retention After 168h IRM 902 Oil Soak at 100°C (%). horizontal bar data: Natural Rubber (NR/SBR) 38.5; Standard PVC (TM2) 52; Standard PCP (EM2) 76.4; Halogen-Free (HM3) 84.5; Heavy-Duty PCP (5GM5) 91.2.Source: TEBAOFLEX Chemical Qualification Lab 2026.

Source: TEBAOFLEX Chemical Qualification Lab, 2026.

Copy-and-Paste 8-Point Engineering Purchase Order (PO) Checklist

Copy the 8-Point PO Specification Table below directly into your Request for Quotation (RFQ) or Purchase Order appendix when procuring heavy-duty or submersible rubber cables. Column 3 shows the actual verified test values from our 2026 production lots (measured via our testing method and test setup in the TEBAOFLEX ISO 9001 Laboratory).

Eight purchase order clauses with technical requirements, reported lot results and compliance labels from the supplied article.

View full-size illustration

PO Clause #.

1. Standard & Voltage Rating.

  • Mandatory Technical Requirement to Write on Your PO.: DIN VDE 0250-812 (0.6/1 kV NSSHÖU), VDE 0250-602 (1.8/3 kV NSGAFÖU), or EN 50525-2-21 (AD8 H07RN8-F).
  • TEBAOFLEX Verified 2026 Lot Result.: Full VDE / EN dimensional & voltage marking verified.
  • Compliance Verdict.: PASS (100% Drum Check).

2. Conductor & Tinning (IEC 60228).

  • Mandatory Technical Requirement to Write on Your PO.: Class 5 finely stranded tinned copper (NSSHÖU / NSGAFÖU) with 20 °C Kelvin bridge DC resistance report.
  • TEBAOFLEX Verified 2026 Lot Result.: 97.8% to 99.1% of max R20 limit; bright Sn coating.
  • Compliance Verdict.: PASS (Zero Sulfide).

3. Dual-Layer Jacket (NSSHÖU).

  • Mandatory Technical Requirement to Write on Your PO.: Extruded GM1b inner sheath + 5GM5 outer sheath (single-layer extrusion strictly rejected).
  • TEBAOFLEX Verified 2026 Lot Result.: Optical projector verified GM1b + 5GM5 dual wall.
  • Compliance Verdict.: PASS (24.6 kN Crush).

4. Hot-Set Crosslink (IEC 60811-507).

  • Mandatory Technical Requirement to Write on Your PO.: 200 °C, 20 N/cm², 15 min on 3GI3 & 5GM5: load elongation max. 100%, permanent set max. 25%.
  • TEBAOFLEX Verified 2026 Lot Result.: 58.4% load elongation / 9.2% permanent set (5GM5).
  • Compliance Verdict.: PASS (Fully Cured CV).

5. Sheath Tear (DIN VDE 0472-613).

  • Mandatory Technical Requirement to Write on Your PO.: Outer sheath trouser tear resistance >= 15.0 N/mm (5GM5) or >= 10.0 N/mm (HM3).
  • TEBAOFLEX Verified 2026 Lot Result.: 18.5 N/mm (5GM5 NSSHÖU) / 12.0 N/mm (HM3 NSHXÖU).
  • Compliance Verdict.: PASS (+23% Margin).

6. Hot Oil Soak (IEC 60811-404).

  • Mandatory Technical Requirement to Write on Your PO.: IRM 902 mineral oil at 100 °C x 168 h: tensile & elongation retention >= 70%.
  • TEBAOFLEX Verified 2026 Lot Result.: 91.2% tensile kept / 88.6% elongation kept (5GM5).
  • Compliance Verdict.: PASS (Oil Proof).

7. AD8 Water Uptake (H07RN8-F).

  • Mandatory Technical Requirement to Write on Your PO.: IEC 60811-402 gravimetric soak (70 °C x 14 d) max. 10.0 mg/cm² + 10 bar autoclave R_iso report.
  • TEBAOFLEX Verified 2026 Lot Result.: 6.4 mg/cm² (H07RN8-F) / 5.2 mg/cm² (S1BC4N8-F).
  • Compliance Verdict.: PASS (AD8 100m Rated).

8. Routine Water-Tank Hipot.

  • Mandatory Technical Requirement to Write on Your PO.: 100% drum immersion AC dielectric test (5 min): 2.5 kV (H07RN8-F), 3.0 kV (NSSHÖU), 6.0 kV (NSGAFÖU).
  • TEBAOFLEX Verified 2026 Lot Result.: Zero breakdown across 100% of dispatched drums.
  • Compliance Verdict.: PASS (Serialized Cert).

To review the complete structural, ampacity, and failure-analysis guides in this cluster, visit: * NSSHÖU, NSSHKCGEÖU & NSHXÖU Heavy-Duty Rubber Cable Guide * NSGAFÖU & NSGAFCMÖU 1.8/3 kV Short-Circuit-Proof Single-Core Cable Guide * NSSHÖU vs H07RN-F vs H07RN8-F Heavy-Duty Rubber Cables Compared * Preventing Oil Swelling, Ozone Cracking & Water Absorption in Rubber Cables

All lab tests follow IEC, DIN VDE, and ISO 9001 quality rules.

Key Takeaways & Frequently Asked Questions (FAQ)

Key Engineering Takeaways for Rubber Cable Procurement

  1. Never Accept a Rubber Cable Shipment Without an IEC 60811-507 Hot-Set Report. It is the only fast laboratory proof that the 3GI3 insulation and 5GM5 jacket were fully crosslinked on the CV steam line.
  2. Require Dual-Layer Cross-Section Photos Before Dispatch on NSSHÖU Orders. Confirming the GM1b inner bedding + 5GM5 outer jacket prevents single-sheath substitutions.
  3. Mandate Gravimetric Water-Uptake (max. 10 mg/cm²) on All H07RN8-F & S1BC4N8-F POs. This guarantees true AD8 underwater longevity.

Frequently Asked Questions (FAQ)

Below are direct engineering answers grounded in DIN VDE and IEC test standards (2026).

How can a buyer verify that an NSSHÖU cable uses genuine 5GM5 polychloroprene instead of cheap SBR or thermoplastic rubber?

Require two laboratory test certificates on the Purchase Order: (1) the IEC 60811-507 Hot-Set test at 200 °C under 20 N/cm² load (a thermoplastic fake melts immediately, whereas genuine crosslinked 5GM5 elongates max. 60%), and (2) the DIN VDE 0472-613 tear-propagation test (>=15.0 N/mm minimum; TEBAOFLEX 2026 batches average 18.5 N/mm).

What routine AC voltage test is required before shipping NSSHÖU, NSGAFÖU, and H07RN8-F drums?

Every full production drum must pass a 5-minute AC water-tank dielectric withstand test: 2.5 kV AC for 450/750 V H07RN-F and H07RN8-F (EN 50525-2-21), 3.0 kV AC for 0.6/1 kV NSSHÖU and NSSHKCGEÖU (DIN VDE 0250-812), and 6.0 kV AC for 1.8/3 kV NSGAFÖU (DIN VDE 0250-602), plus 100% inline high-frequency spark testing.

Why must the PO explicitly specify Class 5 tinned copper for NSSHÖU and NSGAFÖU?

During high-temperature steam vulcanization, sulfur compounds in rubber react with bare copper to form brittle copper-sulfide scales that raise contact resistance at lugs. Specifying IEC 60228 Class 5 tinned copper prevents sulfur corrosion and ensures long-term solderability and crimp integrity in damp mines.

What FAT check confirms that NSSHKCGEÖU will trip a mine ground-fault relay reliably?

For screened NSSHKCGEÖU cables, the factory must verify both the volume resistivity of the extruded semiconductive rubber phase screen (under 500 Ohm.m per DIN VDE 0250-812) and the DC resistance balance of the concentric copper earth screen (K) and pilot monitoring core (ST).

Request a Sample FAT Dossier or a Custom Quote

Ready to source DIN VDE and EN 50525 rubber cables backed by complete pre-shipment laboratory evidence? Contact the TEBAOFLEX Engineering Team or message us on WhatsApp +86 185 9591 3361. We provide live video/photo FAT witnessing and batch-serialized certificates for NSSHÖU Heavy-Duty Rubber Cable, NSSHKCGEÖU Screened Mining Cable, NSGAFÖU 1.8/3 kV Cable, and H07RN8-F Submersible Rubber Cable.