Contact

Technical article · Automotive & Commercial Vehicles

EV Charging & Commercial Vehicle Cables: EN 50620, IEC 62893 & ISO 6722

Engineering guide to EV charging and commercial vehicle cables: compare EN 50620 Mode 3 and IEC 62893-4 Mode 4 / liquid-cooled DC tethers, BS 6724 SWA LSZH + Cat6A forecourt feeders, ISO 19642 FHL2G vs. shielded FHLR2GCB2G 1,500 V HV leads, ISO 6722 primary wiring, and SAE J1939 CAN bus harnesses.

JyenOperations & Technical Engineer16 min read
Commercial electric transit bus fleet lined up at depot DC fast-charging pedestals with heavy charging tethers
Updated
Reading time
16 min read
In this article23 sections
  1. 01Quick Selection Summary Across the Five E-Mobility Voltage Tiers
  2. 02Standard Crosswalk: EN 50620, IEC 62893, UL 2263, ISO 19642, and ISO 6722
  3. 03AC Mode 3 vs. DC Fast-Charging Tether Design Under EN 50620 and IEC 62893-4
  4. H07BZ5-F Mode 3 AC Architecture (450/750 V AC)
  5. Mode 4 DC Dispenser Cables: Air-Cooled vs. Liquid-Cooled (IEC 62893-4)
  6. Worked Engineering Calculation: Uncooled vs. Liquid-Cooled Joule Heating on 50 mm² Copper
  7. 04Why Do Charge-Point Installations Specify Armoured LSZH Power and Cat6A Hybrid Feeders?
  8. 05High-Voltage EV Powertrain Leads: FHL2G vs. Shielded FHLR2GCB2G at 1,000 V AC and 1,500 V DC
  9. When Internal FHL2G (ISO 19642-5) Suffices vs. Mandatory Shielded FHLR2GCB2G (ISO 19642-9)
  10. 06ISO 6722 Primary Wiring and SAE J1939 CAN Bus Harnesses for Commercial Fleets
  11. Comparing ISO 6722 Polymers, Compressed CIVUS, and Aluminum FLALRY
  12. Worked Mass Calculation: Copper vs. Aluminum (ISO 6722-2 FLALRY) on Heavy Chassis Trunks
  13. Protecting 120 Ω SAE J1939 CAN Signals Beside HV Noise
  14. 07TEBAOFLEX EV Charging and Commercial Vehicle Cable Product Selection
  15. 08Factory Acceptance Testing and Procurement Verification Checklist
  16. 09Frequently Asked Questions
  17. 1. What is the difference between EN 50620 and IEC 62893 EV charging cables?
  18. 2. Why do 500 A to 850 A DC fast chargers require liquid-cooled charging cables instead of thicker copper?
  19. 3. When can an electric vehicle use unscreened FHL2G instead of shielded FHLR2GCB2G HV cable?
  20. 4. How does ISO 19642 relate to legacy ISO 6722 automotive wiring standards?
  21. 5. Can unarmoured power cables and regular Ethernet run together in one EV forecourt trench?
  22. 6. Should heavy commercial EV chassis specify SAE J1939-11 shielded or J1939-15 unshielded CAN cable?
  23. 10Image Credits
TL;DR: EV charging and commercial vehicle specialty cables cover five voltage and duty tiers across public plazas and rolling fleets. AC Mode 3 cords (H07BZ5-F, 450/750 V) and DC Mode 4 dispenser tethers (1,000-1,500 V DC, IEC 62893-4-1) use Type EVM-1 PUR jackets. These jackets pass 11,000 N tyre crush and -40 °C cold bending tests. Depot trench feeders combine 0.6/1 kV XLPE power cores with screened Cat6A data inside BS 6724 SWA LSZH steel armour. On the vehicle, 180 °C orange silicone leads (FHL2G unscreened, FHLR2GCB2G screened) keep 1,500 V DC traction noise off 60 V DC ISO 6722 harnesses and 120 Ω SAE J1939 CAN links.

Quick Selection Summary Across the Five E-Mobility Voltage Tiers

Electric transit fleets and fast-charging hubs bridge fixed grid switchgear and moving trucks. Ordinary factory power cords fail quickly here. Dispenser twisting, winter road salt, and fast SiC inverter noise break standard PVC and rubber jackets. Engineers should sort every cable zone by voltage tier, flex cycle count, and heat limit before locking fleet or depot BOMs.

  • Mode 3 AC EV Charging Tether — Core Cable Designations & Standard Basis: H07BZ5-F / H05BZ5-F (EN 50620, IEC 62893-2) | Rated Voltage Envelope: 450/750 V AC (30 V AC CP/PP) | Thermal & Mechanical Limit: -40 °C to +90 °C; 5×OD; 11,000 N tyre crush | Primary Field Failure Mode Prevented: Pilot wire fracture, cold jacket cracks, and kerb wear
  • Mode 4 DC & Liquid-Cooled HPC — Core Cable Designations & Standard Basis: Air 2×25-95 mm² & Liquid 500-850 A (IEC 62893-4-1) | Rated Voltage Envelope: 1,000 / 1,500 V DC (3.5-5 kV test) | Thermal & Mechanical Limit: -40 °C to +90 °C core; sheath ≤ +60 °C; 6×OD | Primary Field Failure Mode Prevented: Gun plug overheating, PLC drops, and strand fatigue
  • Forecourt Power + Data Feeder — Core Cable Designations & Standard Basis: SWA LSZH XLPE + Screened Cat5e / Cat6A (BS 6724) | Rated Voltage Envelope: 0.6/1 kV AC + 3.5 kV data barrier | Thermal & Mechanical Limit: -25 °C to +90 °C (+75 °C Cat6A); 8×OD | Primary Field Failure Mode Prevented: Single-trench OCPP data noise and spade or rodent hits
  • Vehicle HV Powertrain Lead — Core Cable Designations & Standard Basis: FHL2G (ISO 19642-5) & FHLR2GCB2G (ISO 19642-9) | Rated Voltage Envelope: 600/900 V & 1,000 V AC / 1,500 V DC | Thermal & Mechanical Limit: -40 °C to +180 °C; 3×OD (FHL2G) / 4×OD | Primary Field Failure Mode Prevented: SiC inverter CISPR 25 noise and chassis fluid swelling
  • Low-Voltage Primary & Chassis Bus — Core Cable Designations & Standard Basis: FLRY, FLR2X, FL11Y, FLALRY, CIVUS, EPB-WSS, J1939 | Rated Voltage Envelope: 60 V DC / 25 V AC | Thermal & Mechanical Limit: -40 °C to +85 / +105 / +125 °C; 4-6×OD | Primary Field Failure Mode Prevented: Pin corrosion, capillary fluid wicking, and excess mass

Fleet specifiers and EPC teams can browse matching SKUs inside the TEBAOFLEX automotive and commercial vehicles hub.

Standard Crosswalk: EN 50620, IEC 62893, UL 2263, ISO 19642, and ISO 6722

EV charging cables are flexible multi-core cords built under BS EN 50620 and the IEC 62893 series. They carry grid AC or DC power plus control pilot signals from dispenser to car plug. In North America, UL 2263 sets matching rules for Type EV/EVE cords and NACS (SAE J3400) dispensers. Standard mining rubber (H07RN-F) and building wire (NYM, THHN) lack tyre crush, cold torsion, and embedded signal rules.

Public DC fast plazas continue shifting into higher current tiers. Data tracked by the U.S. DOE Alternative Fuels Data Center (2026) shows fast-charger tracking now segments stations up into 150-249 kW, 250-349 kW, and > 349 kW power bands. Higher dispenser power creates tighter thermal and flex limits on every metre of tether.

Public EV DC fast-charging plaza operating outdoors in snow and sub-zero road salt conditions

Outdoor fast chargers sitting in winter snow show why EN 50620 and IEC 62893 mandate -40 °C cold flex, AD7 water defense, and salt-proof EVM-1 PUR jackets. Photo: "Fast Charging Station in Snow.jpg" by WindBorneListener via Wikimedia Commons (CC0), signage retouched.

ISO 19642 is the updated automotive cable series built by ISO/TC 22. It replaces legacy single-core ISO 6722 rules, ISO 14572 screened multi-core specs, and German OEM LV 112 / LV 216 high-voltage sheets. Older harness BOMs still cite ISO 6722-1 thermal classes (Class A +85 °C, B +105 °C, C +125 °C, E +180 °C), JASO D 611 (AVSS, CIVUS), or SAE J1128 (TXL, GXL). Engineers on new electric bus or truck designs should match old codes to ISO 19642 parts (Part 5 unscreened HV, Part 9 screened HV) via the ISO automotive cable standards hub.

CISPR 25 is the automotive EMC emission standard (CISPR 25 Edition 5). It limits RF noise from 150 kHz to 5,925 MHz across EV traction drives and orange HV leads. Meanwhile, SAE J1939-11 and SAE J1939-15 govern 120 Ω twisted-pair CAN buses linking heavy-duty inverters, BMS packs, and brakes.

AC Mode 3 vs. DC Fast-Charging Tether Design Under EN 50620 and IEC 62893-4

Public EV chargers take far harsher abuse than fixed factory wiring. Drivers drag cords across rough tarmac and twist couplers twice per charge. Tyres roll over dropped jackets in winter slush or hot sun. Inside the cord, fragile 0.50 mm² control pilot (CP), proximity (PP), and PT1000 sensor cores twist right next to 2.5-95 mm² power copper.

H07BZ5-F Mode 3 AC Architecture (450/750 V AC)

AC wallboxes and Type 2 pedestals (7.4 kW single-phase to 22 kW or 43 kW three-phase) specify H07BZ5-F AC EV charging cable (62893 IEC 131). Each letter in its CENELEC name locks a concrete layer rule:

  • H and 07 (450/750 V AC): Harmonized European rating tested at 2.5 kV rms on power cores and 1.0 kV rms on pilot cores for 15 minutes.
  • -F (IEC 60228 Class 5): Fine copper strands (2.5-16 mm²) pair with 1 or 2 stranded 0.50 / 0.75 mm² pilot cores. They flex cleanly at 5×OD beyond 30,000 test cycles.
  • B (Type EVI-2 elastomer): Halogen-free cross-linked rubber holds +90 °C continuous heat (+250 °C for 5 s short circuit). Thin pilot wires resist crushing during plug molding.
  • Z5 (Type EVM-1 PUR jacket): Tear-proof polyurethane resists AD7 brief water submersion, road salt, fuel splash, and 11,000 N (5,000 N base class) vehicle tyre drive-over tests.

For light 300/500 V AC portable Mode 2 EV-ICCPD cords (3.7-11 kW), H05BZ5-F AC EV charging cable trims wall weight so cords coil smoothly inside trunk bags.

Mode 4 DC Dispenser Cables: Air-Cooled vs. Liquid-Cooled (IEC 62893-4)

Highway 800-1,000 V DC hubs and e-truck depots deploy DC EV charging cable rated 1,000 / 1,500 V DC. Routine tests apply 6.0 kV DC or 3.5 kV AC on power cores. Mode 4 plugs carry high-frequency ISO 15118 HomePlug GreenPHY PLC frames (or CHAdeMO/GB CAN) plus dual PT1000 temperature pairs. Without tinned braid or foil screens over signal pairs, switching noise from nearby 150-400 kW rectifiers drops live charging sessions.

Above 300 A, air-cooled DC+ and DC- copper cables swell past 35 mm OD and 2.5 kg/m. Drivers struggle to bend thick air-cooled hoses cleanly in winter cold. Upgrading to liquid-cooled high-power DC charging cable (IEC TS 62893-4-2:2021) integrates fluid tubes circulating coolant at 2-4 L/min. This active chiller path sustains 500-850 A inside a 29.5-35.8 mm ergonomic outer jacket.

  • Voltage & Routine Test — H07BZ5-F AC Mode 3: 450/750 V AC; 2.5 kV AC | Uncooled DC Fast (IEC 62893-4-1): 1,000 / 1,500 V DC; 6.0 kV DC | Liquid-Cooled DC (IEC 62893-4-2): 1,000 / 1,500 V DC; 3.5-5.0 kV AC
  • Continuous Current Range — H07BZ5-F AC Mode 3: 16 A to 63 A (2.5-16 mm²) | Uncooled DC Fast (IEC 62893-4-1): 125 A to 300 A (2×25-2×95 mm²) | Liquid-Cooled DC (IEC 62893-4-2): 500 A (50 mm²) to 850 A (95 mm²)
  • Data & Thermal Elements — H07BZ5-F AC Mode 3: 1–2×0.50/0.75 mm² CP / PP | Uncooled DC Fast (IEC 62893-4-1): Shielded PLC/CAN + PT1000 sensor | Liquid-Cooled DC (IEC 62893-4-2): Shielded PLC (ISO 15118) + Dual PT1000
  • Sheath & Surface Touch Cap — H07BZ5-F AC Mode 3: Type EVM-1 PUR; ≤ +60 °C | Uncooled DC Fast (IEC 62893-4-1): Type EVM-1 PUR; ≤ +60 °C | Liquid-Cooled DC (IEC 62893-4-2): EVM-1 PUR; ≤ +50 °C (IEC 61851)
  • Mechanical Endurance — H07BZ5-F AC Mode 3: 5×OD; 11,000 N drive-over | Uncooled DC Fast (IEC 62893-4-1): 6×OD; ±180°/m torsion flex | Liquid-Cooled DC (IEC 62893-4-2): 5-6×OD; 50,000 flex; ≥ 15 bar coolant

Worked Engineering Calculation: Uncooled vs. Liquid-Cooled Joule Heating on 50 mm² Copper

Continuous DC ohmic heat per metre scales with current squared (P_loss = 2 × I² × R_dc). Compare driving a 2×50 mm² annealed copper cord at 300 A (air-cooled ceiling) versus 500 A (mega-charger output). Copper DC resistance starts at 0.386 Ω/km (+20 °C) and reaches 0.0004922 Ω/m at +90 °C core temperature (α = 0.00393 /°C):

1. Uncooled Air Duty at 300 A (2×50 mm² DC+ and DC-):
   P_loss(300A) = 2 * (300 A)^2 * 0.0004922 Ω/m
                = 2 * 90,000 * 0.0004922
                = 88.6 W/m dissipated passively through EVI-2 + EVM-1 walls

2. High-Power Duty at 500 A on the Same 2×50 mm² Copper Section:
   P_loss(500A) = 2 * (500 A)^2 * 0.0004922 Ω/m
                = 2 * 250,000 * 0.0004922
                = 246.1 W/m  (2.78x thermal load vs. 300 A)

3. Engineering Selection Boundary:
   - Uncooled 2×50 mm² exceeds EN 50620 / IEC 61851 hand-touch jacket caps (≤ +60 °C) at 500 A.
   - Forced dielectric fluid at 2.0 to 4.0 L/min extracts 150 to 320 W/m actively,
     keeping a 500 A cord at 29.5 mm OD with outer touch temperature below +50 °C.

Why Do Charge-Point Installations Specify Armoured LSZH Power and Cat6A Hybrid Feeders?

Dispensers also depend on fixed supply feeders from distribution boards to charger pedestals. Digging two separate trenches for 400 V AC power and OCPP data spikes civil excavation costs. Pulling unscreened data wire directly next to mains cables corrupts smart load balancing via 50/60 Hz inductive pickup.

To solve both problems in one pull, installers use armoured LSZH EV charge-point power plus Cat6A hybrid cable built to BS 6724, BS 5467, and BS 7671:

  1. BS 7671 3.5 kV Band I Insulation Barrier: Power cores (3G4 to 5G16 mm² 90 °C XLPE) share one sheath with a screened Cat6A (100 Ω, 1-500 MHz) unit. Its inner sheath withstands 3.5 kV AC testing to legally co-route with 400 V mains.
  2. SWA Impact Defense and Single-Cut Termination: Galvanized steel wire armour (SWA) blocks spade strikes, trench settlement, and rodents. Routing holds an 8×OD bend radius down to 0 °C installation temperature.
  3. LSZH Public-Garage Fire Compliance: Basement car parks demand BS EN 61034-2 low smoke density (≥ 60% light transmittance) and BS EN 60332-3-24 Cat C flame control. Standard PVC SWA feeders emit heavy acid smoke that violates these codes.

For foil versus braid shield impedance comparisons across power cables, review our shielded cable screen selection guide.

High-Voltage EV Powertrain Leads: FHL2G vs. Shielded FHLR2GCB2G at 1,000 V AC and 1,500 V DC

Inside the vehicle inlet, wiring turns safety orange (RAL 2003 / 2008) for 400 V and 800-1,000 V architectures. Traction leads sit inches from 12 V / 24 V ABS sensors and telematics ECUs. Fast SiC inverter dv/dt edges radiate strong EMI if left unshielded. Choosing cleanly between FHL2G and FHLR2GCB2G prevents vehicle dark-room EMC test failures.

Open lithium-ion EV traction battery pack inside a grounded aluminum shield enclosure showing internal module busbars and high-voltage terminals

Open EV lithium-ion traction battery pack inside a grounded aluminum shield enclosure: enclosed module interconnects can use unscreened FHL2G, whereas exposed underbody runs require dual-shielded FHLR2GCB2G. Photo: "Lithium-Ion Battery for BMW i3 - Battery Pack.JPG" by RudolfSimon via Wikimedia Commons (CC BY-SA 3.0), logos removed.

When Internal FHL2G (ISO 19642-5) Suffices vs. Mandatory Shielded FHLR2GCB2G (ISO 19642-9)

For runs sealed inside grounded metal boxes, FHL2G automotive high-voltage cable (ISO 19642-5 Class E / LV 216-1) pairs fine copper strands (FHL) directly with tear-proof silicone rubber (2G). Dropping braid and outer sheaths trims 1×16 mm² OD down to 8.20 mm. Tight 3×D static bends (5×D flexing) fit cramped module busbars and contactor jumpers cleanly.

Outside grounded enclosures, unscreened orange wire leaks switching noise onto nearby low-voltage looms. Inverter-to-motor e-axle drops, onboard chargers (OBC), and fast-charge inlet leads require FHLR2GCB2G shielded automotive HV cable (ISO 19642-9 / LV 216-2). It wraps reduced-wall silicone (R2G) in aluminum-PET foil (B), ≥ 85% tinned copper braid (C), and a second orange silicone jacket (2G). Key qualification metrics include:

  • Dielectric Margin Under Fast Switching: Both families pass 5,000 V AC spark and dielectric tests (≥ 1,000 MΩ·km insulation resistance). Extended ratings handle up to 1,000 V AC / 1,500 V DC safely.
  • 3,000-Hour +180 °C Heat & Fluid Defense: Silicone elastomers endure 3,000 h at +180 °C (+250 °C short-circuit tolerance) and < 70 s self-extinguishing flame checks. Compounds resist ATF, diesel, brake fluid, coolant, and battery electrolyte.
  • 360° EMC Termination Rule: Never fold braids back under plastic zip ties. Clamp B+C dual shields 360° around conductive connector backshells to keep transfer impedance low under CISPR 25.
  • Voltage Envelope — FHL2G Unscreened HV (ISO 19642-5): 600 V AC / 1,000 V DC (ext. 1,500 V DC) | FHLR2GCB2G Screened HV (ISO 19642-9): 600/900 V (ext. 1,000 V AC / 1,500 V DC)
  • EMI Shielding (B + C) — FHL2G Unscreened HV (ISO 19642-5): Unscreened (relies on host enclosure) | FHLR2GCB2G Screened HV (ISO 19642-9): Al/PET foil (B) + ≥ 85% TC braid (C)
  • Thermal Rating (Class E) — FHL2G Unscreened HV (ISO 19642-5): -40 °C to +180 °C (3,000 h), +250 °C SC | FHLR2GCB2G Screened HV (ISO 19642-9): -40 °C to +180 °C (3,000 h), +250 °C SC
  • Min. Bend Radius — FHL2G Unscreened HV (ISO 19642-5): 3×D fixed / 5×D flexing | FHLR2GCB2G Screened HV (ISO 19642-9): 4×D fixed / 6×D flexing
  • Primary Routing Zone — FHL2G Unscreened HV (ISO 19642-5): Inside grounded battery boxes, PDU / BDU taps | FHLR2GCB2G Screened HV (ISO 19642-9): Underbody chassis, inverter-to-e-axle, DC charge inlet

ISO 6722 Primary Wiring and SAE J1939 CAN Bus Harnesses for Commercial Fleets

Low-voltage (60 V DC / 25 V AC) wiring makes up most of the physical cable length inside buses and trucks. Picking the right thin-wall compound stops frame chafing, capillary brine wicking into ECUs, and needless copper weight.

Multi-branch automotive low-voltage wiring harness loom showing color-coded thin-wall primary conductors converged into multi-pin connector blocks

Multi-branch automotive low-voltage instrument wiring loom showing color-coded thin-wall primary conductors converged into multi-pin connector blocks. Photo: "2008-04-17 Geo Storm instrument cluster wiring harness.jpg" by Ildar Sagdejev (Specious) via Wikimedia Commons (CC BY-SA 4.0).

Comparing ISO 6722 Polymers, Compressed CIVUS, and Aluminum FLALRY

We group commercial chassis primary wires across six practical construction options balancing heat rating, scrape wear, and mass.

  • FLRY-A / FLRY-B (ISO 6722-1 Class B, -40 °C to +105 °C): Reduced-wall PVC wire uses 0.20-0.24 mm walls (0.35-1.5 mm²) and 3-5 kV spark testing. Choose concentric Type A strands (7/19 wires) for clean automated stripping, or bunched Type B for flexing door looms.
  • FLR2X (ISO 6722-1 Class C, -40 °C to +125 °C) & SAE J1128 TXL: Cross-linked polyethylene (XLPE) stops melting at +250 °C fault peaks (240 h at +150 °C, 6 h at +175 °C). Halogen-free walls resist hot engine oil and AdBlue/DEF.
  • FL11Y (ISO 6722-1 Class C, -40 °C to +125 °C): TPE-U polyurethane walls boost cut-through and stone-chip scrape survival along bare heavy truck frames (5×OD fixed bend).
  • AVSS vs. CIVUS (JASO D 611 Ultra-Thin-Wall): AVSS uses 0.30 mm PVC walls, while CIVUS (0.13-0.5 mm²) die-compacts copper (88-92% fill) inside a 0.20 mm hard-PVC wall (0.95 mm OD on 0.13 mm²). For example, shifting 100 cab sensor drops to CIVUS 0.13 mm² sharply slims congested A-pillar bundles.
  • FLALRY (ISO 6722-2 Class B Aluminum): Light aluminum cores (60 V DC, -40 °C to +105 °C) trim long bus trunk mass. Installers must seal every splice ultrasonically or use closed-barrel Al-Cu lugs to block galvanic decay.
  • Wet Chassis & Dynamic Axle Protection: Wheel hubs and axles face road spray and tight flexing. Step up to anti-capillary water-blocked TXL / GXL wire (0.35-1.5 mm²) and EPB-WSS hybrid PUR chassis harnesses.

Worked Mass Calculation: Copper vs. Aluminum (ISO 6722-2 FLALRY) on Heavy Chassis Trunks

Long transit bus battery feeds add heavy metal mass across 10-12 m dual-pole runs. Because electrical aluminum achieves ~61% IACS conductivity versus copper (R_Al / R_Cu ≈ 1.64), matching a 35 mm² copper feed uses a 50 mm² (1.43x metric step, or ~60 mm² for identical DC resistance) aluminum FLALRY lead. Using standard metal densities (Cu = 8.89 g/cm³, Al = 2.70 g/cm³):

1. Bare Copper Conductor Mass (35 mm², 100 m twin-pole = 200 m single wire):
   M_Cu = 35 mm² * 8.89 kg/(km*mm²) * 0.200 km = 62.2 kg metal mass

2. Aluminum Equivalent Mass (50 mm² FLALRY, 200 m single wire):
   M_Al = 50 mm² * 2.70 kg/(km*mm²) * 0.200 km = 27.0 kg metal mass

3. Net Harness Weight Savings per 100 m Dual-Pole Chassis Run:
   Delta_M = 62.2 kg - 27.0 kg = 35.2 kg eliminated per chassis trunk
   Note: Specify ultrasonic splice sealing and closed tin-plated Al-Cu lugs at every stud.

Protecting 120 Ω SAE J1939 CAN Signals Beside HV Noise

Heavy electric buses and haul trucks run 250-500 kbps powertrain telemetry across SAE J1939 buses. Deploy SAE J1939 CAN bus cable (120 Ω ± 12 Ω at 1 MHz, ~40 pF/m capacitance, 25-33 twists/m, Yellow CAN_H / Green CAN_L) beside HV motor conduits. Always specify shielded J1939-11 near inverters and keep unshielded J1939-15 strictly inside quiet cab dash zones.

TEBAOFLEX EV Charging and Commercial Vehicle Cable Product Selection

We align our EV charging and commercial vehicle series directly with international standard tests and mechanical bend envelopes. The cutaway renders and summary table below map key TEBAOFLEX designs to their operating duties.

TEBAOFLEX DC EV Charging Cable horizontal cutaway displaying dual power cores, ground core, shielded PLC/PT1000 elements, and EVM-1 PUR sheath

Stepped cutaway of TEBAOFLEX DC EV Charging Cable displaying Class 5/6 DC+ and DC- copper cores, PE ground, screened ISO 15118 PLC and PT1000 pairs, and EVM-1 PUR sheath.

TEBAOFLEX FHLR2GCB2G shielded automotive HV cable cutaway displaying fine copper strands, R2G silicone dielectric, aluminum foil, tinned braid shield, and orange outer sheath

Stepped cutaway of TEBAOFLEX FHLR2GCB2G (ISO 19642-9 / LV 216-2) 1,500 V DC cable showing FHL copper strands, R2G silicone wall, foil screen (B), tinned braid (C ≥ 85%), and 2G orange jacket.

  • H07BZ5-F AC Tether — Governing Standard: BS EN 50620, IEC 62893-2 | Electrical & Thermal Envelope: 450/750 V AC; -40 °C to +90 °C | Core Construction Highlight: Class 5 Cu + EVI-2 elastomer + 1–2×CP/PP + EVM-1 PUR | Target Field Application: Public AC wallboxes, commercial fleet Mode 3 cords (16-63 A)
  • DC EV Charging Cable — Governing Standard: IEC 62893-4-1, EN 50620, UL 2263 | Electrical & Thermal Envelope: 1,000 / 1,500 V DC; -40 °C to +90 °C | Core Construction Highlight: 2×16-95 mm² rope Cu + PE + shielded PLC/CAN & PT1000 | Target Field Application: 125-300 A uncooled CCS1 / CCS2 / NACS / CHAdeMO dispensers
  • Liquid-Cooled DC HPC — Governing Standard: IEC 62893-4-2 | Electrical & Thermal Envelope: 1,000 / 1,500 V DC; 500-850 A | Core Construction Highlight: Chiller coolant channels (2-4 L/min) + dual PT1000 + PUR | Target Field Application: Ultra-fast highway megachargers (350-800 kW) & MCS bays
  • EV Power + Cat6A SWA LSZH — Governing Standard: BS 6724, BS 5467, BS 7671 | Electrical & Thermal Envelope: 0.6/1 kV power + 3.5 kV data isolation | Core Construction Highlight: 3G4-5G16 mm² XLPE + screened Cat6A (100 Ω) + SWA | Target Field Application: Single-trench direct-buried EV plaza & parking deck feeders
  • FHL2G Unscreened HV — Governing Standard: ISO 19642-5, LV 216-1 | Electrical & Thermal Envelope: 600 V AC / 1,000-1,500 V DC; +180 °C | Core Construction Highlight: Extra-flexible FHL copper + single 2G orange silicone; 3×D | Target Field Application: Enclosed HV battery pack modules, PDU/BDU busbar jumpers
  • FHLR2GCB2G Shielded HV — Governing Standard: ISO 19642-9, LV 216-2 | Electrical & Thermal Envelope: 1,000 V AC / 1,500 V DC; +180 °C | Core Construction Highlight: FHL copper + R2G silicone + Al foil + ≥ 85% braid + 2G | Target Field Application: Exposed underbody inverter, e-axle, OBC & DC inlet harnesses
  • FLRY / FLR2X / FL11Y / FLALRY — Governing Standard: ISO 6722-1 / -2, DIN 72551 | Electrical & Thermal Envelope: 60 V DC; +105 °C (B) or +125 °C (C) | Core Construction Highlight: Reduced-wall Cu or Al (FLALRY) in PVC, XLPE, or TPE-U | Target Field Application: Chassis distribution, high-temp engine bays, weight optimization
  • SAE J1939-11 / -15 CAN — Governing Standard: SAE J1939-11 / -15, J1128 | Electrical & Thermal Envelope: 120 Ω ± 12 Ω @ 1 MHz; +125 °C | Core Construction Highlight: 20 / 18 AWG Yellow/Green STP (-11) or UTP (-15), ≤ 40 pF/m | Target Field Application: Heavy electric truck, bus, and off-highway powertrain CAN telemetry

Factory Acceptance Testing and Procurement Verification Checklist

Requiring specific Factory Acceptance Test (FAT) documentation before shipping stops PLC drops, cracked winter tethers, and failed EMC chamber scans. Every TEBAOFLEX drum includes lot-traceable EN 10204 3.1 inspection records and type qualification summaries.

  1. Routine High-Potential Spark and Dielectric Tests: Check spark-test records (3.0-5.0 kV on ISO 6722 wires; 6.0 kV DC or 3.5-5.0 kV AC on charging and ISO 19642 HV leads). Verify +20 °C conductor DC resistance per drum.
  2. Mechanical Crush, Torsion, and Cold-Bend Verification: For EV dispenser cords, review type-test logs for 11,000 N (EN 50620 / IEC 62893-4-1) tyre crush, ±180°/m torsion (≥ 30,000-50,000 cycles), and -40 °C cold winding without cracking.
  3. Coolant Burst and Surface Temperature Limits (Liquid-Cooled HPC): Confirm ≥ 15 bar coolant burst pressure at +85 °C plus flow retention (≥ 90% retained coolant flow, or < 10% restriction, at 5-6×OD). Surface touch heat must stay below +50 °C to +60 °C at rated current.
  4. 3,000-Hour Thermal Aging and Fluid Swell (ISO 19642): Require 3,000 h thermal aging (+180 °C Class E silicone HV, +125 °C Class C FLR2X/FL11Y/J1939). Verify resistance to diesel, ATF, coolant, brake fluid, and AD7 or salt spray.
  5. Halogen-Free Flame and Smoke Certificates: For indoor parking garages (BS 6724 SWA LSZH hybrid) and EV cords, verify IEC 60754-1/2 zero halogen gas, BS EN 61034-2 transmittance (≥ 60%), and IEC 60332-1-2 / 3-24 Cat C flame passes.

For instance, auditing 120 Ω SAE J1939 mutual capacitance (~40 pF/m) and FHLR2GCB2G optical braid density (≥ 85%) before cutting molds prevents costly harness rework later. To learn more about TEBAOFLEX or contact our cable engineers (info@tebaoflex.com), share your voltage class, bend radius, fluid list, and gland drawings with your inquiry.

Frequently Asked Questions

1. What is the difference between EN 50620 and IEC 62893 EV charging cables?

EN 50620 is the CENELEC standard governing EU and UK EV supply cords (H05BZ5-F, H07BZ5-F Mode 2 and Mode 3). IEC 62893 is the global IEC family covering AC cords (IEC 62893-2) and 1,000-1,500 V DC fast dispensers (IEC 62893-4-1 uncooled and IEC TS 62893-4-2 liquid-cooled). Both mandate -40 °C cold bending, halogen-free EVI-2 cores, tough EVM-1 PUR jackets, and 11,000 N tyre crush survival.

2. Why do 500 A to 850 A DC fast chargers require liquid-cooled charging cables instead of thicker copper?

Resistive heat climbs with current squared (2 × I² × R). Pushing a 2×50 mm² cord from 300 A to 500 A raises Joule heat 2.78 times to ~246.1 W/m. That heat drives surface warmth past the +60 °C EN 50620 touch cap. Passive 95-120 mm² copper cords grow above 35 mm OD and turn too stiff to handle. Chilled fluid (2-4 L/min) removes 150-320 W/m inside a sleek 29.5-35.8 mm jacket.

3. When can an electric vehicle use unscreened FHL2G instead of shielded FHLR2GCB2G HV cable?

Run unscreened FHL2G (ISO 19642-5) strictly inside continuous grounded metal boxes, such as closed battery pack trays and sealed PDU / BDU units. Any 600-1,500 V lead crossing onto exposed underbody rails needs screened FHLR2GCB2G (ISO 19642-9). Foil plus ≥ 85% braid terminated 360° at HV connector backshells controls inverter noise under CISPR 25.

4. How does ISO 19642 relate to legacy ISO 6722 automotive wiring standards?

ISO 19642 unifies and replaces legacy single-core copper (ISO 6722-1), aluminum (ISO 6722-2), and multi-core screened (ISO 14572) standards. Old drawings still list FLRY (+105 °C), FLR2X (+125 °C XLPE), FL11Y (+125 °C PUR), and FLALRY aluminum under ISO 6722. New EV and commercial truck programs qualify both 60 V harnesses and 1,500 V leads under ISO 19642.

5. Can unarmoured power cables and regular Ethernet run together in one EV forecourt trench?

No. Routing unseparated Ethernet against 400 V AC power feeds violates BS 7671 Band I 3.5 kV safety rules and injects mains noise into OCPP packets. Combined BS 6724 SWA LSZH hybrid feeders package 3G4-5G16 mm² XLPE power cores with a 3.5 kV-tested screened Cat6A unit inside one steel-wire-armoured jacket.

6. Should heavy commercial EV chassis specify SAE J1939-11 shielded or J1939-15 unshielded CAN cable?

Electric trucks, transit buses, and off-highway machines need shielded SAE J1939-11 (120 Ω, Yellow CAN_H, Green CAN_L, drain plus shield) whenever CAN harnesses pass inverters, battery buses, or DC-DC converters. Reserve unshielded SAE J1939-15 UTP wire strictly for short, isolated cab dashboard branches.

Image Credits

  • Hero cover: "Electric bus charging, New York (9429).jpg" by Marc A. Hermann / MTA via Wikimedia Commons (source), CC BY 2.0, cropped to 1200×630, third-party fleet signage removed.
  • Cold-weather fast-charging bay: "Fast Charging Station in Snow.jpg" by WindBorneListener via Wikimedia Commons (source), CC0.
  • EV traction battery housing: "Lithium-Ion Battery for BMW i3 - Battery Pack.JPG" by RudolfSimon via Wikimedia Commons (source), CC BY-SA 3.0.
  • Vehicle wiring harness loom: "2008-04-17 Geo Storm instrument cluster wiring harness.jpg" by Ildar Sagdejev (Specious) via Wikimedia Commons (source), CC BY-SA 4.0.
  • TEBAOFLEX product cutaways: DC EV Charging Cable and FHLR2GCB2G Shielded Automotive HV Cable technical horizontal cutaway renders produced in-house by TEBAOFLEX.

Editorial & Technical Review: TEBAOFLEX Cable Engineering Team (EN 50620 / IEC 62893 / ISO 19642 / ISO 6722 / SAE J1939 Compliance).

Specify it

Sizes, technical data and documents for each cable.

Armoured LSZH EV Charge-Point Power and Cat6A Hybrid Cable — horizontal cutaway

Power connection cables

EV Power + Cat6A SWA LSZH

BS 6724 / BS 7671 0.6/1 kV 3G4–5G16 mm² XLPE power + screened Cat6A SWA armoured LSZH EV

Rated voltage
0.6/1 kV AC
Standard
BS 6708
Sizes and data →
CIVUS — horizontal cutaway

Equipment & hook-up wires

CIVUS

60 V DC compressed-conductor ultra-thin-wall (0.20 mm) PVC ECU harness wire (0.13–0.5 mm²)

Rated voltage
60 V DC / 25 V A
Standard
IEC
Sizes and data →
DC EV Charging Cable — horizontal cutaway

Power connection cables

DC EV Charging Cable

1000–1500 V DC IEC 62893-4-1 Mode 4 CCS1/CCS2/NACS fast-charging cable (125–800 A)

Rated voltage
1000 V / 1500 V
Standard
BS 6708
Sizes and data →