Switchgear & control cabinet wiring
Engineered and verified for cabinet chassis service in accordance with ISO 6722-2 Class B / LV 112-2.
Product
FLALRY (ISO 6722-2) Thin-Wall PVC-Insulated Stranded Aluminum Automotive Battery/Harness Wire (FLALRY) engineered to ISO 6722-2 Class B / LV 112-2 for 60 V DC service across -40 °C to +105 °C, featuring stranded aluminum conductor and thin-wall pvc insulation
Typical values for this cable type, based on ISO 6722-2 Class B / LV 112-2 — confirmed in the datasheet and quotation for your order.
Application fit
FLALRY (ISO 6722-2) Thin-Wall PVC-Insulated Stranded Aluminum Automotive Battery/Harness Wire (FLALRY) engineered to ISO 6722-2 Class B / LV 112-2 for 60 V DC service across -40 °C to +105 °C, featuring stranded aluminum conductor and thin-wall pvc insulation
Engineered and verified for cabinet chassis service in accordance with ISO 6722-2 Class B / LV 112-2.
Qualified for fixed installation on trays, racks, conduits or supports per ISO 6722-2 Class B / LV 112-2.
Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.
Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.
NSHTOU Reeling CableConstruction
Shown: FLALRY (ISO 6722-2 Class B / LV 112-2) with stranded aluminum conductor, thin-wall pvc insulation and thin-wall pvc insulation (2-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded aluminum conductor | High-conductivity aluminum conductor per ISO 6722-2 Class B / LV 112-2ISO 6722-2 Class B / LV 112-2 |
| 2 | Thin-wall PVC insulation | Extruded Thin-wall PVC insulation dielectric (continuous layer)ISO 6722-2 Class B / LV 112-2 |
Built to ISO 6722-2 Class B / LV 112-2 with stranded aluminum conductor and thin-wall pvc insulation
Full range of metric mm² and AWG/kcmil conductor sizes per ISO 6722-2 Class B / LV 112-2
Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate
Technical data
Sizes
Manufactured to ISO 6722-2 Class B / LV 112-2 across standard single-core and multi-core cross-sections.
| Order designation | Configuration | Outer Ø ≈ mm | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|
| FLALRY Standard Production Schedule (60 V DC · −40…+105 °C) | |||||
| FLALRY 3G1.5 | 3 × 1.5 mm² | 8.4 | 105 | 68 | |
| FLALRY 4G1.5 | 4 × 1.5 mm² | 9.2 | 128 | 74 | |
| FLALRY 5G1.5 | 5 × 1.5 mm² | 10.1 | 156 | 81 | |
| FLALRY 3G2.5 | 3 × 2.5 mm² | 9.8 | 148 | 78 | |
| FLALRY 4G2.5 | 4 × 2.5 mm² | 10.8 | 186 | 86 | |
| FLALRY 5G2.5 | 5 × 2.5 mm² | 11.9 | 228 | 95 | |
| FLALRY 4G4 | 4 × 4.0 mm² | 12.6 | 268 | 101 | |
| FLALRY 4G6 | 4 × 6.0 mm² | 14.2 | 365 | 114 | |
| FLALRY 4G10 | 4 × 10 mm² | 17.5 | 580 | 140 | |
| FLALRY 4G16 | 4 × 16 mm² | 20.4 | 845 | 163 | |
| FLALRY 4G25 | 4 × 25 mm² | 24.8 | 1,290 | 198 | |
| FLALRY 4G35 | 4 × 35 mm² | 27.9 | 1,710 | 223 | |
| Cross-section | Max. DC R₂₀ Ω/km | Current in air A (30 °C) ≈ | Voltage drop mV/A·m |
|---|---|---|---|
| 1.5 mm² (AWG 16) | 13.30 | 18 | 29.0 |
| 2.5 mm² (AWG 14) | 7.98 | 26 | 17.5 |
| 4.0 mm² (AWG 12) | 4.95 | 34 | 10.9 |
| 6.0 mm² (AWG 10) | 3.30 | 44 | 7.3 |
| 10 mm² (AWG 8) | 1.91 | 61 | 4.2 |
| 16 mm² (AWG 6) | 1.21 | 82 | 2.7 |
| 25 mm² (AWG 4) | 0.78 | 108 | 1.7 |
| 35 mm² (AWG 2) | 0.55 | 135 | 1.2 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (ISO 6722-2 Class B / LV 112-2) | DC resistance at 20 °C and geometry within ISO 6722-2 Class B / LV 112-2 class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (ISO 6722-2 Class B / LV 112-2) | Zero breakdown or structural defect over full production length | Every manufactured drum / spool |
| Sample tests | ||
| Thermal aging, mechanical & material qualification (ISO 6722-2 Class B / LV 112-2) | Full compliance with ISO 6722-2 Class B / LV 112-2 across −40…+105 °C | Type qualification & periodic sample audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.