What the video shows
82 s 1080p60 factory showcase of TEBAOFLEX 0.6/1 kV NSSHÖU-J (NSSHOU-J) 3x150 + 1G70 mm² DIN VDE 0250-812 safety-yellow mining and tunneling jumbo trailing cable covering hard-rock shotcrete headings, online 5GM5 sheath printing, 4-layer 3D teardown, and 4K specimen QC.
The video illustrates a sample, process, or operating context. Final product construction, suitability, standards, and test acceptance criteria are confirmed against the ordered specification.
TL;DR: 0.6/1 kV NSSHÖU-J (NSSHOU-J) 3x150 + 1G70 mm² is a DIN VDE 0250-812 safety-yellow trailing cable built with IEC 60228 Class 5 tinned copper and 3GI3 90 °C EPR insulation. Light-grey GM1b inner bedding and a 5GM5 polychloroprene outer jacket (~73.1 mm OD) support up to 7,800 N axial tension. Although 150 mm² free-air ampacity reaches 424 A at 30 °C (DIN VDE 0298-4:2023-06), 2 or 3 layers coiled on a jumbo drum at 35 °C drop continuous capacity to 236 A or 190 A. Always verify drum payout, a 10 × D (731 mm) reel core radius, and all 6 DIN VDE 0250-812 FAT checks before shipment.
Watch the 1:22 factory showcase video on the NSSHÖU-J 3x150+70 video engineering page. It documents hard-rock shotcrete tunneling (00:06), wet granite percussion drifters (00:12), and skid-to-jumbo motorized reel routing (00:17). It also shows online 0.6/1KV 3X150+70mm2 sheath printing and drum take-up (00:24), 4-layer 3D teardown (00:36), and specimen QC (00:59). Our methodology applies IEC 60228 Class 5 resistance, DIN VDE 0298-4 reel derating, DIN VDE 0298-3 tensile limits, and IEC 60949 fault math to our factory-verified 3x150 + 1G70 mm² sample.
| Engineering Parameter | 0.6/1 kV NSSHÖU-J (NSSHOU-J) 3x150 + 1G70 mm² Value | Governing Standard / Reference |
|---|---|---|
| Conductor System | 3 × 150 mm² phases + 1G70 mm² PE (520 mm² total Cu), Class 5 tinned Cu | IEC 60228 Class 5 / DIN VDE 0295 |
| Core Insulation & Colors | 3GI3 cross-linked EPR (+90 °C / +250 °C SC); Brown, Black, Grey, Green-Yellow | DIN VDE 0207-20 / DIN VDE 0293-308 |
| Dual Rubber Sheath | Light-grey GM1b extruded inner sheath + safety-yellow 5GM5 PCP outer jacket | DIN VDE 0207-21 / DIN VDE 0250-812 |
| Rated & Max Voltage | 0.6/1 kV nominal; max 1.2 kV AC / 1.8 kV DC; 3.0 kV AC 5-minute routine test | DIN VDE 0250-812 |
| Outer Diameter & Tension | ~73.1 mm nominal OD; max permissible axial tension 7,800 N (15 N/mm²) | TEBAOFLEX 2026 QC / DIN VDE 0298-3 |
| Thermal & Bend Window | -25 °C to +80 °C flexing (-40 °C fixed); 10 × D (731 mm) jumbo reel radius | DIN VDE 0250-812 / DIN VDE 0298-3 |
| Ampacity Range (30 °C) | 424 A free air; 404 A floor; 323 A (1L), 246 A (2L), 198 A (3L) on drum | DIN VDE 0298-4 / TEBAOFLEX Datasheet |
| Showcase Video Runtime | 1 minute 22 seconds (1920×1080 60 fps, 6 technical chapters) | TEBAOFLEX 2026 Factory Archive |
1. Why Hard-Rock Tunneling Headings Shred Standard Rubber Cable
NSSHÖU-J (NSSHOU-J) Trailing Cable is an extra-heavy-duty 0.6/1 kV double-sheathed elastomeric power cable specified under DIN VDE 0250-812 for ground dragging and motorized reeling in mines and hard-rock tunnels (DIN VDE 0250-812:1985-05). Unlike light H07RN-F construction leads built for portable tools, a multi-boom drill jumbo drags a 73.1 mm trunk across blasted granite, drainage water, and hydraulic oil spills on every cycle.

Abrasive Blasted Rock, Flushing Water, and Vehicle Run-Over
During drill-and-blast excavation (00:06 to 00:16 in our showcase video), percussion drifters flood the face with pressurized flushing water while rock chips litter the concrete invert. Ordinary single-sheath neoprene leads (such as EN 50525-2-21 H07RN-F) lack an extruded elastomeric bedding layer. Consequently, sharp granite edges slice directly into the insulated phase cores, and dark black sheaths disappear into tunnel mud where wheel loaders run right over them.
5GM5 Polychloroprene Outer Sheath is a heavy-duty vulcanized elastomer specified under DIN VDE 0207-21 to deliver tear propagation resistance of at least 30 N/mm (VDE 0472-613) and abrasion volume loss at or below 300 mm³ (VDE 0472-605 A). Pigmented in high-visibility safety yellow, the 5GM5 armor resists hydraulic oil immersion (EN 60811-404:2012) and vertical flame spread (IEC 60332-1-2:2025) while standing out clearly against dark wet rock floors.
Core Migration Under S-Curve Reeling and Asymmetric 3x150+1G70 Protection
Beneath the yellow outer jacket, GM1b Extruded Inner Sheath is a pressure-extruded light-grey thermoset rubber bedding that fills every interstice around the four laid-up cores (DIN VDE 0207-21:1993-07). By locking the three 150 mm² phase conductors and single 70 mm² earth conductor into a solid circular profile, GM1b prevents internal core corkscrewing when the cable winds repeatedly onto the jumbo's rear drum.
Inside that bedding, 3GI3 EPR Insulation is a cross-linked ethylene-propylene rubber dielectric rated for 90 °C continuous conductor operation and 250 °C short-circuit spikes (DIN VDE 0207-20:1993-07). Compared against standard H07RN-F (60 °C continuous EPR limit), 3GI3 EPR unlocks substantially higher thermal headroom under warm tunnel ventilation. For a full side-by-side comparison across European rubber cable standards, see our NSSHÖU vs. H07RN-F and H07RN8-F comparison guide.
2. How Multi-Layer Jumbo Reel Derating Slashes 150 mm² Ampacity
Sizing a tunneling jumbo power feeder from the 424 A free-air column is the fastest way to cook a brand-new 73.1 mm trailing cable. When a drill jumbo parks 25 m from the tunnel skid substation, 60 m to 95 m of cable remains tightly wound in two or three stacked layers on the rear motorized reel. Trapped radial heat slashes continuous current capacity by 39% on two layers and 51% on three layers compared to uncoiled floor routing (DIN VDE 0298-4:2023-06).
| Routing & Drum Winding Condition | DIN VDE 0298-4 Factor | 30 °C Ambient | 35 °C Ambient (0.96) | 40 °C Ambient (0.91) | 50 °C Ambient (0.82) | Field Tunneling Risk Assessment |
|---|---|---|---|---|---|---|
| Free Air (Single Cable Suspended) | 1.00 | 424 A | 407 A | 386 A | 348 A | Overhead hook suspension only; never valid for wound reels |
| Uncoiled Flat on Tunnel Floor | 0.95 | 404 A | 388 A | 368 A | 331 A | Valid only when 100% of cable is paid off the drum |
| Motorized Reel, 1 Layer Remaining | 0.80 | 323 A | 310 A | 294 A | 265 A | Recommended operating target for 200 kW to 260 kW jumbos |
| Motorized Reel, 2 Layers Remaining | 0.61 | 246 A | 236 A | 224 A | 202 A | Thermal pinch point; trips 250 A continuous jumbo loads |
| Motorized Reel, 3 Layers Remaining | 0.49 | 198 A | 190 A | 180 A | 162 A | Severe inner-layer overheating; uncoil cable before drilling |
Base 30 °C ampacities reflect TEBAOFLEX NSSHÖU 150 mm² datasheet and DIN VDE 0298-4:2023-06 (90 °C EPR conductor; reel factors 0.80, 0.61, and 0.49 apply to the 404 A floor-laid baseline); ambient factors use sqrt[(90 - T_amb) / 60] per DIN VDE 0298-4 Table 17.
Worked Tunneling Jumbo Calculation (690 V three-phase AC, 250 A Load)
For example, consider a three-boom electro-hydraulic tunneling jumbo powered by a 690 V 3-phase 50 Hz skid transformer drawing 250 A RMS continuous (254 kW active power at cos phi = 0.85, sin phi = 0.527). The rig carries 120 m of TEBAOFLEX 0.6/1 kV NSSHÖU-J 3x150 + 1G70 mm² inside a 35 °C heading, with 60 m paid out on the wet invert and 60 m still coiled on the rear drum. Each phase uses R_20 = 0.132 Ω/km max tinned Class 5 copper (IEC 60228), X = 0.080 Ω/km, and a ~8.0 kg/m heavy dual-sheath build.
Step 1: Audit Remaining Drum Layers Under 35 °C Heading Ambient
Because the same 250 A phase current passes through the coiled turns, the innermost drum layer sets the continuous thermal ceiling (DIN VDE 0298-4:2023-06).
Ambient factor at 35 °C (90 °C EPR conductor, DIN VDE 0298-4): f_t = sqrt[(90 - 35)/60] = 0.96
2 layers left on jumbo drum: I_z,2L = 246 A * 0.96 = 236.2 A (< 250 A FAIL)
1 layer left on jumbo drum: I_z,1L = 323 A * 0.96 = 310.1 A (>= 250 A PASS)
3 layers left on jumbo drum: I_z,3L = 198 A * 0.96 = 190.1 A (< 250 A SEVERE OVERHEAT)Operators must pay out the trailing cable into figure-eight floor loops beside the skid transformer until no more than 1 layer stays on the jumbo reel (310 A ≥ 250 A PASS). Drilling continuously at 250 A with 2 or 3 layers coiled drives inner-layer copper above 90 °C and accelerates EPR embrittlement.
Step 2: Check 120 m Full-Circuit Voltage Drop and Coiled Reel Heating
Next, scale the 20 °C DC conductor resistance (0.132 Ω/km) to 90 °C (alpha_20 = 0.00393 /°C), apply a 1.015 50 Hz skin-and-proximity multiplier, and compute three-phase line drop plus continuous resistive heat generated across all 120 m (IEC 60228, 2023).
R_90,dc = 0.132 * [1 + 0.00393 * (90 - 20)] = 0.1683 Ω/km
R_90,ac = 0.16831 * 1.015 = 0.17084 Ω/km (rounded 0.1708 Ω/km)
dV = sqrt(3) * 250 A * 0.120 km * (0.17084 * 0.85 + 0.080 * 0.527)
= 51.962 * (0.1452 + 0.0422) = 9.74 V (1.41% of 690 V PASS)
P_loss = 3 * (250 A)^2 * 0.17084 Ω/km * 0.120 km = 3,844 W total (32.0 W/m)
Reel heat (60 m left on drum) = 60 m * 32.03 W/m = 1,922 W (1.92 kW inside drum)Line voltage drop stays at 1.41% of nominal 690 V, well under the 3% to 5% motor feeder threshold (IEC 60364-5-52:2009+AMD1:2024). However, leaving 60 m coiled traps 1.92 kW of continuous resistive heater output directly inside the drum windings, illustrating physically why multi-layer payout discipline matters.
Step 3: Verify 7,800 N Axial Pulling Margin and 70 mm² PE Fault Survival
Next, check ground-drag tension against the DIN VDE 0298-3 ceiling of 15 N/mm² across total active copper area (3 × 150 + 70 = 520 mm²). Then verify adiabatic fault survival on both 150 mm² phases and the 70 mm² earth core using k = 143 A·s^0.5/mm² for 90 °C to 250 °C EPR (IEC 60949:1988+AMD1:2008).
Max permissible axial tension: F_max = 15 N/mm² * 520 mm² = 7,800 N (7.80 kN)
60 m ground drag (8.0 kg/m, wet crushed rock mu = 0.60):
F_drag = 8.0 kg/m * 60 m * 9.81 m/s² * 0.60 = 2,825 N (2.83 kN) -> 2.76x safety factor PASS
Short-circuit (150 mm² phase, 1.0 s): I_sc = 143 * 150 / sqrt(1.0) = 21.5 kA RMS
Short-circuit (70 mm² PE, 1.0 s / 0.5 s): I_pe = 10.0 kA (1.0 s) / 14.2 kA (0.5 s) PASSThe 2.76x pulling margin absorbs transient snags over shotcrete ridges safely, while the 70 mm² PE core satisfies IEC 60364-5-54 Table 54.2 earth-fault clearing requirements on 690 V mine substations.
3. Inside the 4-layer NSSHÖU-J 3x150+70 Dual-Sheath Architecture and Heavy Trailing Cable Selection
Chapters 03 and 04 of our factory video (00:36 to 00:58) reveal how every layer of TEBAOFLEX 0.6/1 kV NSSHÖU-J 3x150 + 1G70 mm² builds concentric crush resistance and wet-tunnel reliability.

- Layer 01, Class 5 Fine-Stranded Tinned Copper Conductors (3x150 + 1G70 mm²): Electrolytic annealed fine tinned copper wires meet IEC 60228 Class 5 (≤ 0.132 Ω/km on 150 mm² phases; ≤ 0.277 Ω/km on 70 mm² earth at 20 °C). Tinning resists alkaline shotcrete mist and sulfurous mine drainage water.
- Layer 02, 3GI3 EPR Rubber Core Insulation (+90 °C): Cross-linked ethylene-propylene elastomer (DIN VDE 0207-20) insulates each core in HD 308 / DIN VDE 0293-308 colors (Brown, Black, Grey for 150 mm² phases plus Green-Yellow -J for 70 mm² earth) with +250 °C short-circuit stability.
- Layer 03, Light-Grey GM1b Extruded Rubber Inner Sheath: Pressure-extruded GM1b bedding fills all four core interstices tightly rather than using loose polypropylene tape fillers. It stabilizes core geometry against radial drum crush and blocks longitudinal water tracking.
- Layer 04, Safety-Yellow 5GM5 Polychloroprene Outer Sheath (~73.1 mm OD): Extra-heavy cross-linked 5GM5 PCP delivers ≥ 30 N/mm tear strength and ≤ 300 mm³ abrasion loss (DIN VDE 0207-21). Crisp dark-charcoal dot-matrix printing (0.6/1KV 3X150+70mm2, shown at 00:24) confirms full production traceability.

Asymmetric 3x150 + 1G70 mm² vs. Adjacent NSSHÖU-J Heavy Mining Configurations
Procurement engineers frequently choose between the single-PE 3x150 + 1G70 mm² heavy dual-sheath build featured in our video and symmetrical split-earth 3x150 + 3x70/3E mm² or adjacent NSSHÖU heavy-duty rubber cable frames. Comparing exact outer diameters, tensile ratings, and ampacities prevents reel-flange clearance surprises.
| Configuration (mm²) | Earth Core Geometry | Outer OD (mm) | Weight (kg/km) | Max Pull (15 N/mm²) | Floor / Air (30 °C) | 1L / 2L Reel (30 °C) |
|---|---|---|---|---|---|---|
| 3x120 + 3x70/3E | 3 split earth cores in interstices | 48.5 to 50.3 | 5,990 | 5,400 N (phase) | 352 A / 370 A | 282 A / 215 A |
| 3x150 + 3x70/3E | 3 split earth cores (symmetrical) | 54.3 to 56.1 | 7,030 | 6,750 N (phase) | 404 A / 424 A | 323 A / 246 A |
| 3x150 + 1G70 (Video) | Single 70 mm² Green-Yellow PE | ~73.1 (HD) | ~8,000 | 7,800 N (total) | 404 A / 424 A | 323 A / 246 A |
| 4x150 (Equal 4C) | Full-size 150 mm² 4th core | 60.6 to 62.9 | 8,270 | 9,000 N (total) | 404 A / 424 A | 323 A / 246 A |
| 3x185 + 3x95/3E | 3 split earth cores (symmetrical) | 61.7 to 64.0 | 9,030 | 8,325 N (phase) | 461 A / 484 A | 369 A / 281 A |
Split-earth and 4x150 values reflect the TEBAOFLEX NSSHÖU catalog; 3x150 + 1G70 (~73.1 mm OD, 7,800 N total-copper tension) matches the heavy-wall tunneling specimen filmed in NSSHOU-J 3×150+70.mp4.
Choose 3x150 + 1G70 mm² when site maintenance teams prefer terminating a single heavy 70 mm² earth lug inside skid plugs and demand extra-thick rubber wall armor against blasting fly-rock. Choose 3x150 + 3x70/3E mm² when drum width is tightly constrained or high-power VFD drives require symmetrical three-way earth shielding to suppress common-mode shaft currents.
Heavy-Duty Mining & Tunneling Rubber Cable Selection Matrix
NSSHÖU-J excels at heavy ground trailing and intermittent jumbo drum reeling, but continuous high-speed festooning, concentric earth-fault monitoring, or North American MSHA sites require specialized siblings. Match your exact duty boundary across TEBAOFLEX's live product families below.
| TEBAOFLEX Product Family | Voltage & Core System | Governing Standards | Primary Application Boundary | When to Choose Over NSSHÖU-J 3x150+70 |
|---|---|---|---|---|
| NSSHÖU Heavy-Duty Rubber Cable | 0.6/1 kV, 3C to 24C & 3+PE | DIN VDE 0250-812, 3GI3 EPR, GM1b + 5GM5 | Tunnel jumbos, quarry crushers, roadheaders, heavy mine skids | Baseline choice for unscreened 1 kV heavy ground trailing and jumbo reels |
| NSHCGEOEU Monitored Trailing Cable | 0.6/1 kV, 3C + concentric PE (KON) + control (ST) + monitor (ÜL) | DIN VDE 0250-812, overall concentric earth (KON) / pilot monitor (ÜL) | Underground coal or metalliferous mines with pilot trip relays | Mandatory when regulations require continuous concentric screen earth-fault tripping |
| NSHTÖU High-Speed Reeling Cable | 0.6/1 kV, anti-torsion braided reel | DIN VDE 0250-814, embedded textile braid | High-speed LHD scooptrams, port cranes, stacker-reclaimers | Required for continuous high-speed reeling cycles (see NSHTÖU-J 3x70 LHD video) |
| NTSCGEWÖU / NSSHÖU-3E Heavy Mining | 6/10 kV MV dredger/mine (0.6/1 kV 3E in NSSHÖU series), 3+3E symmetrical | DIN VDE 0168 / DIN VDE 0250-812 / -813, semiconductive screen | High-capacity TBM feeders, electric shovels, MV mine rings | Mandatory when equipment operates above 1 kV or requires symmetrical 3E earth screens |
| ICEA / NEMA / MSHA Type W Cable | 2000 V, 2C to 4C documented (1C to 5C per ICEA S-75-381) | ICEA S-75-381, NEMA WC-58, MSHA 30 CFR 7 | North and South American mines governed by MSHA / NEC | Required where MSHA P-number print and 2000 V UL/ICEA compliance replace VDE |
For deeper cross-comparisons between unscreened NSSHÖU, screened NSSHKCGEOEU, and halogen-free NSHXÖU tunnel builds, review our NSSHÖU vs. NSSHKCGEOEU vs. NSHXÖU engineering guide.
4. Jumbo Reel Geometry, 10 × D Drum Sizing, and 6-point DIN VDE 0250-812 FAT
Even a genuine 5GM5 rubber cable will fail prematurely if a jumbo's rear cable drum or tunnel floor guide saddle violates bending or torsion geometry. On modern multi-boom electro-hydraulic drill rigs, the rear motorized reel constantly alternates between high-torque payout during heading advance and multi-layer take-up during blast retreat.

Reconciling 4 × D Fixed Bends vs. 10 × D Motorized Jumbo Reel Drums
Engineers often spot two different bending multiples across NSSHÖU technical sheets: 4 × D in static catalogs versus 10 × D displayed in Chapter 06 (01:12) of our showcase video. Both figures are technically accurate for completely different mechanical regimes under DIN VDE 0298-3:2006-06. For our 73.1 mm OD 3x150 + 1G70 mm² cable, enforce three clear thresholds on site:
- Fixed Skid Entry (4 × D = 292 mm): Applies only to permanently clamped, non-flexing turns inside the tunnel substation skid or behind strain-relief brass glands.
- Free Ground Trailing S-Curves (6 × D = 439 mm; 5 × D free-movement floor): Applies to floor guide saddles and curved tunnel walls (00:17 in our video) where the cable slides without wrapping under drum torque (exceeding the 5 × D free-movement floor in our NSSHÖU datasheet).
- Motorized Jumbo Reel Core Radius (10 × D = 731 mm): Mandatory minimum bending radius (731 mm reel core radius, corresponding to a 1,462 mm barrel diameter) when winding 73.1 mm multicore cable under up to 7,800 N tension. Undersized reel cores crush inner-layer 3GI3 insulation and accelerate Class 5 copper fatigue.
- Floor Guide Saddle & Slip-Ring Hygiene: Install wide-radius elastomeric floor saddles at every tunnel drift corner and verify rear slip-ring brush torque quarterly. For example, a misaligned steel deflection roller with a 200 mm radius introduces over 3.6 times the target bending strain on a 73.1 mm trunk and fractures 150 mm² Class 5 strands within weeks.
6-point DIN VDE 0250-812 Factory Acceptance Test (FAT) Protocol
Every yellow export wooden drum shown in Chapter 02 (00:24) and Chapter 05 (00:59) of our video completes structured laboratory and line verification at TEBAOFLEX Manufacturing under our documented Quality and Certifications program. Require all six verifiable FAT records in your pre-shipment pack (see also our DIN VDE 0250-812 FAT and PO checklist):
| FAT Checkpoint | Test Method & Acceptance Criterion | Governing Standard | Inspection Scope |
|---|---|---|---|
| 1. Class 5 Tinned Cu & 20 °C DC Resistance | Verify fine-stranded tinned wire integrity and 20 °C DC resistance ≤ 0.132 Ω/km (150 mm²) and ≤ 0.277 Ω/km (70 mm²) | IEC 60228 Class 5 / DIN VDE 0295 | Every production reel |
| 2. Routine 3.0 kV AC Dielectric Withstand | Completed cable withstands 3.0 kV AC (50 Hz) for 5 minutes without breakdown, plus in-line core spark test | DIN VDE 0250-812 | Every production reel |
| 3. Dual-Sheath Wall & 73.1 mm OD Audit | Optical/micrometer check of 3GI3 wall thickness, concentric GM1b inner filling, yellow 5GM5 thickness, and ~73.1 mm OD | DIN VDE 0250-812 Table 1 & 2 | Every extrusion batch |
| 4. 5GM5 Tear & Abrasion Compound Test | Compound batch verification confirming tear resistance ≥ 30 N/mm (VDE 0472-613) and abrasion loss ≤ 300 mm³ (VDE 0472-605 A) | DIN VDE 0207-21 | Every 5GM5 batch |
| 5. Hydraulic Oil Immersion Verification | Hot mineral oil immersion testing verifying tensile and elongation retention within DIN VDE 0207-21 5GM5 limits | EN 60811-404 / VDE 0472-803 A | Type test & periodic audit |
| 6. Vertical Flame & -25 °C Cold-Flex Audit | Self-extinguishing single-cable vertical flame propagation and crack-free flexing performance down to -25 °C (-40 °C fixed) | IEC 60332-1-2 / DIN VDE 0250-812 | Type test & periodic sample |
Need custom cut lengths of 0.6/1 kV NSSHÖU-J 3x150+1G70 mm², symmetrical 3x150+3x70/3E VFD builds, or factory-mounted heavy mining couplers with a full 6-point FAT dossier? Contact TEBAOFLEX engineering at info@tebaoflex.com or direct WhatsApp +86 185 9591 3361 with your jumbo reel barrel diameter, heading ambient temperature, and required cable length.
Authored by Jyen, Technical Editor for DIN VDE 0250, IEC 60228, and ICEA S-75-381 underground mining and tunneling power cables at Jiangsu Tebaoflex Special Cable Co., Ltd.
Frequently Asked Questions
1. How many amps can 0.6/1 kV NSSHÖU-J 3x150+70 mm² carry when coiled on a jumbo reel?
At 30 °C ambient, a 150 mm² NSSHÖU-J cable carries 424 A in free air and 404 A uncoiled on the tunnel floor (DIN VDE 0298-4). However, multi-layer drum winding restricts cooling sharply: continuous ampacity drops to 323 A on 1 layer (0.80), 246 A on 2 layers (0.61), and 198 A on 3 layers (0.49). In a 35 °C heading (0.96 factor), 2 remaining layers carry only 236 A, so operators feeding a 250 A jumbo must uncoil down to 1 layer (310 A).
2. Why specify NSSHÖU-J 3x150+1G70 mm² instead of 3x150+3x70/3E mm²?
Both designs provide 70 mm² of protective earth copper meeting IEC 60364-5-54 for 150 mm² phase circuits. The single-PE 3x150 + 1G70 mm² build simplifies field plug termination to one 70 mm² earth lug and uses an extra-heavy ~73.1 mm dual rubber profile built for fly-rock and crush protection. By contrast, 3x150 + 3x70/3E mm² reduces outer diameter to 54.3 mm to 56.1 mm and balances zero-sequence impedance on VFD-driven equipment.
3. What is the maximum permissible pulling tension on NSSHÖU-J 3x150+1G70 mm²?
Under DIN VDE 0298-3, flexible copper trailing cables permit a maximum continuous axial pulling stress of 15 N/mm² across the total active copper cross-section. With 3 × 150 + 70 = 520 mm² of Class 5 copper, NSSHÖU-J 3x150+1G70 mm² supports up to 7,800 N (7.80 kN) axial tension. Dragging 60 m of 8.0 kg/m cable over wet crushed granite (mu = 0.60) generates about 2,825 N, preserving a 2.76x tensile safety factor.
4. Why does the video specify a 10 × D bending radius when some datasheets list 4 × D?
The 4 × D minimum bending radius (292 mm for a 73.1 mm OD cable) applies strictly to stationary, permanently clamped entries inside switchgear skids (DIN VDE 0298-3). Free-trailing ground S-curves require at least 6 × D (439 mm). On a motorized tunneling jumbo drum winding a 73.1 mm multicore trunk under tension, engineers must specify a 10 × D minimum bending radius (731 mm reel core radius) to avoid inner-layer insulation crush and copper strand fatigue.
5. Which 6 factory acceptance tests should buyers verify on NSSHÖU-J 3x150+70 before shipment?
Buyers should audit all 6 DIN VDE 0250-812 checkpoints before releasing drums. First, verify IEC 60228 Class 5 tinned copper DC resistance at 20 °C (≤ 0.132 Ω/km phase; ≤ 0.277 Ω/km earth). Second, confirm the 3.0 kV AC 5-minute dielectric withstand and spark test. Third, audit 3GI3, GM1b, and 5GM5 wall concentricity plus ~73.1 mm OD. Fourth, check 5GM5 tear (≥ 30 N/mm) and abrasion (≤ 300 mm³) batch tests. Fifth and sixth, confirm EN 60811-404 oil immersion, IEC 60332-1-2 flame, and -25 °C cold-flex reports.
References and Visual Credits
- DIN VDE 0250-812 (1985-05): Cables, Wires and Flexible Cords for Power Installation, Part 812: Rubber-Sheathed Flexible Cables Type NSSHÖU, VDE Verlag / DIN.
- DIN VDE 0207-20 & DIN VDE 0207-21 (1993-07): Insulating Compound 3GI3 and Sheathing Compounds GM1b / 5GM5 for Heavy-Duty Rubber Cables, VDE.
- DIN VDE 0298-3 (2006-06) & DIN VDE 0298-4 (2023-06): Permissible Tensile Stress, Bending Radii, and Current-Carrying Capacity (Multi-Layer Reeling Factors), DIN VDE 0298-4 (DKE) and DIN.
- IEC 60228 (2023): Conductors of Insulated Cables (Class 5 Fine-Stranded Tinned Copper Resistance), IEC 60228:2023 Webstore.
- IEC 60364-5-52 (2009+AMD1:2024) & IEC 60364-5-54 (2011+AMD1:2021): Voltage Drop Guidelines and Protective Earth Conductor Sizing (Table 54.2), IEC.
- IEC 60949 (1988+AMD1:2008): Calculation of Thermally Permissible Short-Circuit Currents (Adiabatic Copper Constant k = 143), IEC.
- EN 60811-404 (2012) & IEC 60332-1-2 (2025): Mineral Oil Immersion Test and Vertical Flame Propagation for Single Insulated Cables, CEN-CENELEC.
- MSHA 30 CFR Part 7 (Subpart K) & ICEA S-75-381: North American Mining Trailing Cable Standards (Type W Alternative), eCFR 30 CFR Part 7 Subpart K (MSHA) and ICEA.
Visual & Media Credits
- Cover photo (hero.webp): Retouched from CH Gotthard Basistunnel Amsteg 1.jpg by Daniel Schwen (contractor branding and project signage removed), licensed under CC BY-SA 2.5 via Wikimedia Commons.
- Section 1 tunnel heading photo (nsshou-wet-shotcrete-tunnel-heading.webp): Bodio - GBT Bypass tunnel (30488222391).jpg by Kecko, licensed under CC BY 2.0 via Wikimedia Commons.
- Section 4 tunneling jumbo drill photo (nsshou-tunneling-jumbo-drill-reel.webp): Retouched from Bohrwagen-Sprengvortrieb.jpg by Störfix (contractor signage removed), licensed under CC BY-SA 3.0 via Wikimedia Commons.
- Section 3 product cutaway and 4K specimen frames (nsshou-j-3x150-70-4-layer-architecture.webp, nsshou-j-3x150-70-specimen-qc-gallery.webp): TEBAOFLEX in-house factory production archive (NSSHOU-J 3×150+70.mp4).