Contact

Special Customized Cable

Cables engineered to project-specific construction, marking, and approval requirements.

How does the cable move?

Pick one or more duties — the list below updates.

17 special customized cable

Voltage
Standard
Sheath
Features

Control cables

Multicore control and signal cables for machine and system circuits.

1 cable
Baulift-T / -W — Construction Hoist Cable Baulift-T / Baulift-W
BAULIFT-T / BAULIFT-WBAULIFT-T / BAULIFT-W 300/500 V Construction Hoist & Lift Cable
300/500 V
Free-hanging, hoist & mast, pendant station
DIN VDEPUR
300/500 V, DIN VDE, PUR sheathFree-hanging, hoist & mast, pendant station

Power & connection cables

From 100 V welding leads to 45 kV feeders, with portable cords, EV charging and solar cables.

16 cables
AC Bare-Cu Braid Shunt cross-section showing core arrangement and orange outer profile
AC Bare-Cu Braid ShuntAC Bare Copper Flat Braided Flexible Shunt & Busbar Strap
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
AC Bare-Cu Rope 120-700 cross-section showing core arrangement and red outer profile
AC Bare-Cu Rope 120-700AC Bare Copper Flexible Rope 120–700 mm² Uninsulated Lead
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
AC Laminated Cu-Foil Lead cross-section showing core arrangement and orange outer profile
AC Laminated Copper-Foil Flexible Busbar Expansion LeadAC Laminated Copper-Foil Flexible Busbar Expansion Lead
1000 V
Fixed, control cabinet
DIN VDE
1000 V, DIN VDE, sheathFixed, control cabinet
EAF Heat-Shield 500°C Cable cross-section showing core arrangement and black outer profile
EAF 500 °C Heat-Shielded Water-Cooled Furnace CableEAF 500 °C Heat-Shielded Water-Cooled Furnace Cable
1000 V
Fixed, furnace & kiln
DIN VDEGlass braid
1000 V, DIN VDE, Glass braid sheathFixed, furnace & kiln
EAF Anti-Chafing Bumper Cable cross-section showing core arrangement and grey outer profile
EAF Anti-Chafing Bumper Water-Cooled Furnace CableEAF Anti-Chafing Bumper Water-Cooled Furnace Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
EAF Swivel-End Sleeved Cable cross-section showing core arrangement and black outer profile
EAF Swivel-End & Anti-Abrasion Sleeved Water-Cooled CableEAF Swivel-End & Anti-Abrasion Sleeved Water-Cooled Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
EAF Wear-Indicator Hose Cable cross-section showing core arrangement and black outer profile
EAF Water-Cooled Cable with Dual-Layer Wear-Indicator HoseEAF Water-Cooled Cable with Dual-Layer Wear-Indicator Hose
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
SAF Water-Cooled Cable cross-section showing core arrangement and black outer profile
SAF Submerged Arc Furnace Water-Cooled Feeder CableSAF Submerged Arc Furnace Water-Cooled Feeder Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
UL Tinned-Cu Braid Strap cross-section showing core arrangement and grey outer profile
UL Tinned-Cu Braid StrapUL Tinned Copper Flat Grounding & Bonding Braid Strap
600 V
Fixed, control cabinet
UL / CSA
600 V, UL / CSA, sheathFixed, control cabinet
WC Center-Channel 95-500 Cable cross-section showing core arrangement and black outer profile
WC Center-Channel 95–500 mm² Water-Cooled Power CableWC Center-Channel 95–500 mm² Water-Cooled Power Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Hollow-Core 10kHz Litz cross-section showing core arrangement and black outer profile
WC Hollow-Core 10kHz LitzWC Hollow-Core 10 kHz Litz Water-Cooled Induction Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Hollow-Core 2 kHz Cable cross-section showing core arrangement and black outer profile
WC Hollow-Core 2 kHz Water-Cooled Induction CableWC Hollow-Core 2 kHz Water-Cooled Induction Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Multi-Rope 1200-2000 Cable cross-section showing core arrangement and black outer profile
WC Multi-Rope 1,200–2,000 mm² Ultra-High-Current CableWC Multi-Rope 1,200–2,000 mm² Ultra-High-Current Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Single-Core 120-1000 Cable cross-section showing core arrangement and black outer profile
WC Single-Core 120–1,000 mm² Water-Cooled Feeder CableWC Single-Core 120–1,000 mm² Water-Cooled Feeder Cable
1000 V
Fixed, furnace & kiln
DIN VDERubber
1000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Tin-Plated 3000 V Cable cross-section showing core arrangement and black outer profile
WC Tin-Plated 3,000 V Water-Cooled HV Induction CableWC Tin-Plated 3,000 V Water-Cooled HV Induction Cable
3000 V
Fixed, furnace & kiln
DIN VDERubber
3000 V, DIN VDE, Rubber sheathFixed, furnace & kiln
WC Unipolar Weld Cable cross-section showing core arrangement and black outer profile
WC Unipolar 120–500 mm² Water-Cooled Welding CableWC Unipolar 120–500 mm² Water-Cooled Welding Cable
600 V
Fixed, furnace & kiln
DIN VDERubber
600 V, DIN VDE, Rubber sheathFixed, furnace & kiln

Choosing special customized cable

Four things decide most selections. Our engineers check the rest against your application.

01 · Mechanical duty & installation profile

  • Match minimum bending radius, travel speed, and tensile load to the active duty profile (Free-hanging vertical run, Fixed installation, Furnace, kiln & high-temp zone, Switchgear & control cabinet wiring).
  • For continuous reeling, festoon, or drag-chain motion, specify fine-stranded Class 5/6 copper conductors with central strain-relief or anti-torsion braid.

02 · Rated voltage & cable family scope

  • This collection spans Control cables, Power & connection cables, grouped below so power feeders, control circuits, and data/optical links can be specified side by side.
  • Account for voltage drop, ambient temperature derating, and symmetrical EMC screening on long runs or VFD motor drives.

03 · Standards compliance & outer sheath compound

  • Verify the governing regional or industry standard required by the project specification (IEC, VDE/DIN, UL, BS, ICEA/MSHA, etc.).
  • Use the outer-sheath filter to lock in PUR, heavy-duty EPR/PCP rubber, or low-smoke zero-halogen (LSZH) compounds for oil, abrasion, or fire safety.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
What rated voltages are available in the Special Customized Cable category?

Rated voltages run from 300/500 V to 3000 V across all 17 products. The most common rating is 1000 V, listed for 13 products.

Which standards do the products in the Special Customized Cable category reference?

The products reference VDE / DIN Standard (all 17 products), IEC Standard (16 products), and UL Standard (1 product).

Are PDF datasheets available for the products in the Special Customized Cable category?

Yes. All 17 products have a PDF datasheet, linked from each product card and product page.

Engineering reference

Background on how special customized cable are built, rated and specified.

Read the full reference

The Special Customized Cable collection brings together 17 industrial cable models across Control cables, Power & connection cables. Cables engineered to project-specific construction, marking, and approval requirements.

Use the multi-facet filter bar and duty matrix view to compare rated voltage, governing standard, outer sheath compound, and mechanical duty ratings side by side, or add candidate models to a combined engineering enquiry.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features