- Location
- Hai Phong Port, Vietnam
- Application
- Port STS, RMG, and RTG quay crane monospiral 6.6 kV flat reeling power supply
- Cable type
- 6.6 kV F-3PNCT 3x50 mm² flat medium-voltage EPR/PCP rubber reeling cable →
- Evidence
- 4 images
TL;DR: A port crane operator at Hai Phong Port (Cảng Hải Phòng), Vietnam needed a joint-free replacement for an aging medium-voltage flat reeling cable. TEBAOFLEX built 6.6 kV F-3PNCT 3 x 50 mm², combining Japanese flat cabtyre design with metric 50 mm² tinned copper (≤ 0.393 Ω/km at 20 °C). The six-layer EPR and polychloroprene build passes 17 kV AC testing for 10 minutes, bends down to 7.5 × D, resists 4,900 N/m side pressure, and ships under stage-by-stage QC.
- Project Location: Hai Phong Port (Cảng Hải Phòng), northern Vietnam coastal container terminal
- Project Scope: Direct replacement of an aging medium-voltage crane reel power cable
- Cable Designation: TEBAOFLEX 6.6 kV F-3PNCT 3 x 50 mm² (flat 3-core medium-voltage rubber reeling cable)
- Voltage & Routine AC Test: 6.6 kV (6,600 V) rated; 17 kV (17,000 V) AC withstand for 10 minutes
- Thermal Rating: -15 °C to +80 °C operating range; +80 °C maximum conductor temperature
- Mechanical Limits: 7.5 × D minimum bend radius (D = bending-plane finished dimension); 4,900 N/m side pressure
- 6-layer Construction: Tinned annealed Cu, inner/outer semicon tapes, EPR, fibrous/Cu-yarn screen, reinforcement, black CR sheath
- Core ID & Delivery: Coloured fibrous braid (Red, White, Blue); single continuous joint-free length on export drum
1. Project Context: Replacing Aging 6.6 kV Port Crane Reeling Cable in Hai Phong
Flat medium-voltage cabtyre reeling cable (6.6 kV F-3PNCT) is a three-core parallel rubber power cable. It combines tinned copper conductors, semiconductive tapes, EPR insulation, copper-yarn screens, and a black polychloroprene sheath for single-plane crane reels.
At Hai Phong Port (Cảng Hải Phòng), quay cranes face salt spray, heavy rain, coastal humidity, solar UV, and hydraulic oil mist every day. Ship-to-shore (STS) cranes, rail-mounted gantry (RMG) cranes, rubber-tyred gantry (RTG) cranes, and mobile harbor cranes travel along quayside rails around the clock. Their 6.6 kV power cables wind and unwind repeatedly across monospiral drums and trench guide rollers.
Older reeling cables fail from jacket wear, insulation hardening, or core fatigue after years of dockside cycles. Replacing a worn lead on an active berth leaves very little margin for installation error. Every replacement cable must match the existing drum pocket, fairlead width, and electrical rating on the first lift.
Field Video Walkthrough (00:08 Terminal Crane Footage)
An 8.2 s site clip from the Hai Phong container terminal confirms the exact crane class and berth setting. The footage tracks three working zones across the quay:
- 00:00 to 00:02: Low-angle view up the blue steel portal legs and red-and-white boom of the quay cranes above the berth rail track.
- 00:03 to 00:04: Wide pan across twin quay crane machinery houses towering over multi-tier container blocks.
- 00:05 to 00:06: Yard-level sweep past a green container handler spreader and terminal truck lane beside stacked container rows.
- 00:07 to 00:08: Return pan across the twin crane machinery houses and coastal portal leg frames under open berth weather.

Across our material handling and port crane cable range and crane reeling cable portfolio, three site hazards drive cable wear on active container berths.
- Tight drum flange and roller clearance. Existing monospiral reels and trench fairleads leave narrow width gaps. Any oversize outer jacket rubs against steel roller cheeks and binds between reel spokes.
- Repeated bending and sidewall crushing. Each crane pass pulls the flat lead out of a recessed quay trench and over multi-roller guides. High reeling tension then presses the flat sheath tightly onto the spiral drum.
- Salt fog and moisture at worn spots. Coastal air corrodes untinned copper quickly. Meanwhile, cracked jackets or poorly sealed joints allow water ingress under 6.6 kV stress.
2. Why Specify 6.6 kV F-3PNCT 3x50 mm² Between Standard JIS 38 mm² and 60 mm² Sizes?
Port engineers often hit a sizing mismatch when matching Japanese cabtyre catalogues to Vietnamese crane drawings.
JIS cabtyre standard cross-section stepping is the Japanese conductor series (14, 22, 38, 60, and 100 mm²). It skips the metric 50 mm² intermediate size commonly used in IEC 60228 port switchgear.
Engineers must also separate low-voltage standards from medium-voltage reeling cables. Published Japanese Industrial Standard JIS C 3327 covers 600 V rubber cabtyre cables (1PNCT, 2PNCT, and 3PNCT), which undergo a 3.0 kV test for 1 minute. By contrast, 6.6 kV F-3PNCT applies medium-voltage field-control design principles aligned with IEC 60502-2 medium-voltage power cables. It adds inner and outer semiconductive tapes, braided copper-yarn core screens, thicker EPR insulation, and a 17 kV AC withstand test for 10 minutes.
For example, consider a Hai Phong crane already equipped with 3 x 50 mm² lugs and a monospiral reel cut for 50 mm² flat geometry. Picking a standard catalogue JIS size creates immediate engineering trade-offs:
- Stepping down to 3 x 38 mm² raises resistance. DC resistance climbs to 0.525 Ω/km, compared with ≤ 0.393 Ω/km at 20 °C for 50 mm² Class 5 tinned copper under IEC 60228:2023 Conductors of Insulated Cables. Higher resistance increases I^2 R heating and quay-run voltage drop.
- Stepping up to 3 x 60 mm² expands cable bulk. Standard size grows to 34.0 x 80.0 mm (up to 35.7 x 84.0 mm maximum), and weight reaches 4,880 kg/km. That extra width and mass can jam existing roller fairleads and strain the reel drive motor.
Mechanical Bending, Tension, and Side-Pressure Checks
Three mechanical checks confirm whether a 6.6 kV F-3PNCT replacement will survive continuous berth travel. For example, engineers verify bend radius, side pressure, and conductor tensile stress before locking the drum drawing:
1. Minimum bending radius (flat minor axis D):
R_min = 7.5 * D
Check: 3 x 38 mm² (D = 30.8 mm) -> R_min = 231 mm
3 x 60 mm² (D = 34.0 mm) -> R_min = 255 mm
2. Sidewall crushing pressure over reel barrel or guide sheave of radius R:
F_side = T / R <= 4,900 N/m
At T = 3,300 N (3 x 38 mm² max pull), required R >= 3,300 / 4,900 = 0.674 m (design >= 0.68 m)
3. Specific tensile loading across standard F-3PNCT reinforced sizes:
sigma_t = F_max / (3 * A_phase) = 28.6 to 29.3 N/mm²
Check: 3 x 60 mm² -> 5,200 N / 180 mm² = 28.9 N/mm²Thermal sizing also depends on northern Vietnam summer heat and coiled drum layers. Under DIN VDE 0298-4:2023-06 Current-Carrying Capacity Rules, ambient air above 30 °C and coiled layers require derating factors. Proper derating keeps conductor heat below the +80 °C continuous F-3PNCT ceiling.
As a result, TEBAOFLEX produces 6.6 kV F-3PNCT 3 x 50 mm² as a regular Vietnam export build alongside 3x14, 3x22, 3x38, 3x60, and 3x100 mm². This custom metric bridge preserves full 50 mm² current margin while holding finished height and width inside existing reel limits. To compare Japanese rubber classes and drum sizing rules, read our 2PNCT versus 3PNCT JIS C 3327 guide, our crane reeling cable selection guide, and our JIS cable standards hub.
3. Inside TEBAOFLEX 6.6 kV F-3PNCT: 6-layer Architecture, Size Range, and Port Reeling Alternatives
Flat medium-voltage cables need uniform electric-field control around every parallel core. Otherwise, repeated bending across crane sheaves can crack the insulation screen and trigger partial discharge.
Semiconductive field-control screening is the paired inner and outer semiconductive tape system around each 6.6 kV core. It smooths radial electric stress between stranded copper, EPR insulation, and the metallic braid to prevent partial discharge.

Six-Layer Flat Medium-Voltage Construction
Each layer in TEBAOFLEX 6.6 kV F-3PNCT solves a specific electrical or mechanical stress on coastal cranes. Callouts 1 through 6 in the cross-section schematic above correspond directly to the six construction layers below, with red, white, and blue coloured fibrous braids identifying the three phases.
- Flexible Tinned Annealed Copper Conductors. Fine stranding keeps bending stiffness low on crane reels. Tin plating stops rubber-cure sulfur staining and slows coastal salt corrosion.
- Inner Semiconductive Tape. This conductive layer wraps tightly over the stranded copper wire. It removes micro-voids that cause electrical treeing at 6.6 kV.
- Ethylene Propylene Rubber (EPR) Insulation. Flexible thermoset EPR operates from -15 °C to +80 °C. Every core passes a 17,000 V AC withstand test for 10 minutes.
- Outer Semiconductive Tape and Metallic Screen. An outer semiconductive tape sits beneath a fibrous and copper-yarn braid. This supple screen drains charging current and resists fatigue better than rigid copper tape.
- Coloured Fibrous Braid and Reinforcement. Red, white, and blue braids mark all three phases cleanly during termination. Internal reinforcement absorbs 4,900 N/m side pressure and repeated reeling pull.
- Black Polychloroprene (CR / PCP) Flat Outer Sheath. Heavy chloroprene rubber protects against concrete trench abrasion and roller wear. It also resists crane hydraulic oil mist, rain, ozone, and UV sun.
Next, the studio macro below shows TEBAOFLEX's three-core flat medium-voltage EPR and chloroprene construction. You can inspect the stranded copper cores, dark inner semiconductive rings, thick EPR insulation, concentric metallic screens, and flat black sheath.

Standard Size Range: TEBAOFLEX 6.6 kV F-3PNCT Reference Catalogue Table
The table below lists nominal catalogue values for the standard Japanese 6.6 kV F-3PNCT series. For custom 3 x 50 mm² orders, TEBAOFLEX confirms final height, width, tolerance, and weight on the approved production drawing between the 3 x 38 mm² and 3 x 60 mm² limits.
- 3 x 14 — Nominal Conductor Dia. (mm): 4.9; Standard Overall Size (mm, H x W): 26.4 x 60.2; Maximum Overall Size (mm, H x W): 27.7 x 63.2; Approx. Weight (kg/km): 2,440; Max. Conductor Resistance (Ω/km): 1.39; Permissible Tensile Force (kN): 1.2
- 3 x 22 — Nominal Conductor Dia. (mm): 7.0; Standard Overall Size (mm, H x W): 28.3 x 65.1; Maximum Overall Size (mm, H x W): 29.7 x 68.4; Approx. Weight (kg/km): 2,950; Max. Conductor Resistance (Ω/km): 0.892; Permissible Tensile Force (kN): 1.9
- 3 x 38 — Nominal Conductor Dia. (mm): 9.1; Standard Overall Size (mm, H x W): 30.8 x 71.8; Maximum Overall Size (mm, H x W): 32.3 x 75.4; Approx. Weight (kg/km): 3,760; Max. Conductor Resistance (Ω/km): 0.525; Permissible Tensile Force (kN): 3.3
- 3 x 50 (Custom IEC Bridge) — Nominal Conductor Dia. (mm): Per approved drawing; Standard Overall Size (mm, H x W): Sized between 38 and 60 mm²; Maximum Overall Size (mm, H x W): Locked to crane reel clearance; Approx. Weight (kg/km): Per approved drawing; Max. Conductor Resistance (Ω/km): ≤ 0.393 (IEC 60228 Cl. 5 tinned); Permissible Tensile Force (kN): Per approved drawing
- 3 x 60 — Nominal Conductor Dia. (mm): 11.6; Standard Overall Size (mm, H x W): 34.0 x 80.0; Maximum Overall Size (mm, H x W): 35.7 x 84.0; Approx. Weight (kg/km): 4,880; Max. Conductor Resistance (Ω/km): 0.329; Permissible Tensile Force (kN): 5.2
- 3 x 100 — Nominal Conductor Dia. (mm): 15.2; Standard Overall Size (mm, H x W): 38.2 x 91.0; Maximum Overall Size (mm, H x W): 40.1 x 95.6; Approx. Weight (kg/km): 6,720; Max. Conductor Resistance (Ω/km): 0.193; Permissible Tensile Force (kN): 8.8
Comparing TEBAOFLEX Port Crane Reeling Cable Families
Port terminals often operate mixed fleets built to Japanese (JIS) or European (DIN VDE) designs. Compare 6.6 kV F-3PNCT with TEBAOFLEX's low-voltage, European flat, fiber-hybrid, and round reeling options below.
- 6.6 kV F-3PNCT (This Case) — Standard Basis & Voltage: Japanese MV flat cabtyre basis; 6.6 kV (17 kV / 10 min AC test); Geometry & Bending Plane: Flat 3-core (7.5 × D single-plane bending; 4,900 N/m side pressure); Primary Port Crane Application: Japanese-design STS, RMG, RTG, and mobile harbor crane monospiral reels (3x14 to 3x100 mm², incl. 3x50 mm²)
- PNCT / 2PNCT / 3PNCT Cabtyre Cable — Standard Basis & Voltage: JIS C 3327; 600 V (3.0 kV / 1 min AC test); Geometry & Bending Plane: Round (10 × OD moving; 19.8 N/mm² max pull); Primary Port Crane Application: Low-voltage festoons, carrier drums, hoppers, and auxiliary yard equipment
- (N)TSFLCGEWÖU MV Flat Reeling Cable — Standard Basis & Voltage: DIN VDE 0250-813; 3.6/6 kV & 6/10 kV (11 / 17 kV AC test); Geometry & Bending Plane: Flat 3- or 4-core + concentric split earth (red 5GM5, single plane, 120 m/min); Primary Port Crane Application: European-spec STS and gantry crane monospiral drums (3x25 to 3x120 mm²)
- WGF / WGF-D Flat MV + 6-FO Cable — Standard Basis & Voltage: DIN VDE 0250; 3.6/6 to 8.7/15 kV (11 to 24 kV AC test); Geometry & Bending Plane: Flat + optional 6 FO optical core (single plane only, 15 N/mm² pull); Primary Port Crane Application: Automated monospiral gantry cranes combining MV power and optical telemetry
- (N)TSCGEWÖU Round MV Reeling Cable — Standard Basis & Voltage: DIN VDE 0250-813; 1.8/3 to 18/30 kV (20/35 kV R-type; ≤ 40 pC PD); Geometry & Bending Plane: Round + anti-torsion braid (12 × OD reeling; ±100 °/m torsion); Primary Port Crane Application: Cylindrical multi-layer drums and multi-plane deflection routes where flat cables cannot twist
In addition, you can review our port terminal electrification master guide for full berth planning. Related Vietnam cases include our Ho Chi Minh City NGFLGOEU-J 3x50+1x16 mm² flat cable study, our 0.6/1 kV 3PNCT RTG spreader cable video, and our Vietnam coal-plant reeling cable case.
4. Stage-by-Stage Dimensional QC, 17 kV AC FAT, and Container Dispatch to Hai Phong
Flat 6.6 kV cables ride inside rigid steel roller guides and narrow monospiral drum pockets. Even when electrical tests pass, a few millimeters of dimensional drift can ruin crane reel fit.
Continuous joint-free single-reel delivery is a production and Factory Acceptance Test (FAT) standard. It guarantees one uninterrupted cable length on a single export drum with zero factory splices or repair patches.
How TEBAOFLEX Controls Finished Dimensions and Routine Tests
Before copper stranding starts, our engineers prepare an order-specific process sheet. Next, the team confirms finished height, width, tolerances, marking, and single-reel length against the customer's crane drawing.
During manufacturing, QC inspectors verify semi-finished dimensions after every single stage. They measure conductor diameter, EPR insulation thickness, screened core build, and final chloroprene sheath profile. These dimensional checks follow IEC 60811-202 non-metallic sheath measurement procedures so small errors never stack up at final extrusion.
Every finished 6.6 kV F-3PNCT drum then completes a 10-point outgoing FAT inspection before packing. The routine factory test report covers every electrical and physical gate below:
- 1. Conductor DC Resistance — Routine Factory Verification Scope: Measured at 20 °C across all 3 cores (≤ 0.393 Ω/km for 50 mm² Cl. 5); Purpose on Port Crane Replacement: Confirms copper purity, cross-section, and ampacity margin
- 2. Insulation Resistance — Routine Factory Verification Scope: Routine DC megaohm measurement on each EPR core; Purpose on Port Crane Replacement: Detects pinholes, moisture, or curing defects early
- 3. 17 kV AC Dielectric Test — Routine Factory Verification Scope: 17,000 V AC applied continuously for 10 minutes; Purpose on Port Crane Replacement: Proves 6.6 kV insulation and semiconductive screen integrity
- 4. Structure & Core Layout — Routine Factory Verification Scope: Layer-by-layer verification of Red/White/Blue cores and braid; Purpose on Port Crane Replacement: Confirms exact alignment with the approved construction drawing
- 5. Outer Flat Dimensions — Routine Factory Verification Scope: Caliper measurement of final finished height and width; Purpose on Port Crane Replacement: Guarantees smooth travel through trench guides and monospiral spokes
- 6. Outer Sheath Thickness — Routine Factory Verification Scope: Minimum and average chloroprene wall measurement; Purpose on Port Crane Replacement: Confirms abrasion reserve over concrete trenches and rollers
- 7. Surface Appearance — Routine Factory Verification Scope: Visual inspection across the complete finished run; Purpose on Port Crane Replacement: Rejects blisters, scratches, or uneven jacket curing
- 8. Length & Meter Marks — Routine Factory Verification Scope: Sequential meter-mark audit across the whole reel; Purpose on Port Crane Replacement: Verifies exact delivery length and tolerance
- 9. Sheath Legend Printing — Routine Factory Verification Scope: Contrast and accuracy check of voltage, model, and brand print; Purpose on Port Crane Replacement: Simplifies dockside maintenance and future spare ordering
- 10. Joint-Free Confirmation — Routine Factory Verification Scope: Full-run verification of zero mid-length splices or patches; Purpose on Port Crane Replacement: Prevents weak flex points under dynamic crane tension
For example, if a terminal also requires type tests such as reverse-bending endurance, abrasion testing, or IEC 60332-1-2 vertical flame propagation testing, buyers lock those standards into the purchase contract upfront.
Before paying the final balance, buyers receive actual finished-cable photos, factory videos, meter marks, sheath print close-ups, drum labels, and the factory test report. Buyers can also send a third-party inspector or visit the TEBAOFLEX factory directly.

For sea freight to Hai Phong, finished cable winds onto heavy steel-rimmed wooden export reels blocked with floor chocks and ratchet tie-downs. Batten-enclosed drums receive green PET strapping and cross-lashed orange container straps to prevent movement during maritime transit.
5. Pre-Order Engineering Checklist for 6.6 kV Port Reeling Cable Replacements
Before ordering 6.6 kV F-3PNCT (3x14 to 3x100 mm², including 3x50 mm²) port crane cables, confirm six technical details with our engineers. Checking these parameters early prevents drum interference and avoids costly site delays.
- Confirm 6.6 kV system voltage and earthing method. Share system neutral earthing details so screen design matches crane relay protection.
- Send full crane reel and roller geometry. Provide drum core diameter, flange inner width, guide-roller diameter, travel speed, runway length, and daily cycles to check 7.5 × D bending and 4,900 N/m side pressure.
- Verify single-plane versus multi-plane cable travel. Keep flat F-3PNCT strictly in single-plane monospiral reeling. Choose round (N)TSCGEWÖU whenever multi-plane deflection or torsion occurs.
- Declare site oils and seal all medium-voltage terminations. List any special hydraulic oils, fuels, or chemical exposures upfront. Always pair the chloroprene sheath with properly sealed waterproof 6.6 kV terminations.
- Lock continuous length tolerance and optional type tests. Specify single-reel joint-free length, allowed length tolerance, and any third-party witness or optional type tests before signing the order.
- Confirm pre-balance FAT files and export drum format. Agree on sheath print text, meter marks, steel-rimmed or batten-enclosed packing, and pre-shipment photo or video checks.
Editorial Note: All specifications, construction details, and QC steps in this case study were reviewed by Jyen (Operations & Port Crane Cable Engineering Desk). Explore our About TEBAOFLEX factory and testing page or contact our engineering desk with your drum drawing for a fast project quotation.
Image Credits: Hero cover photo retouched from "Chùa Vẽ Terminal, Port of Hải Phòng.JPG" by Phó Nháy via Wikimedia Commons (Public Domain; third-party crane and container branding removed). Hai Phong crane reel and trench guide scene, numbered 6.6 kV F-3PNCT six-layer diagram, three-core flat MV cross-section macro, and export container stowage photos by TEBAOFLEX.
Frequently Asked Questions
Which port machines use 6.6 kV F-3PNCT 3x50 mm² flat reeling cable?
6.6 kV F-3PNCT 3 x 50 mm² powers mobile medium-voltage port equipment on single-plane motorized or spring-driven reels. Typical machines include ship-to-shore (STS) quay cranes, RMG and RTG gantry cranes, mobile harbor cranes, ship unloaders, and bulk stacker-reclaimers.
Why is 6.6 kV F-3PNCT 3x50 mm² custom-built instead of using standard JIS 38 mm² or 60 mm²?
Standard Japanese F-3PNCT size tables jump directly from 3 x 38 mm² to 3 x 60 mm². Cranes equipped with metric 50 mm² switchgear lose current capacity on 38 mm² (0.525 Ω/km) or risk drum-flange rubbing on wider 60 mm² (34.0 x 80.0 mm). Custom 3 x 50 mm² meets both electrical and mechanical clearances.
How does TEBAOFLEX verify that the finished flat cable fits an existing crane reel?
Before manufacturing begins, our engineers build a process sheet aligned with the approved crane reel drawing. QC technicians measure semi-finished dimensions after stranding, insulation, screening, and sheathing. Finally, they measure finished height and width before dispatch.
Can TEBAOFLEX supply 6.6 kV F-3PNCT in one continuous joint-free length?
Yes. TEBAOFLEX manufactures the ordered run as one continuous cable length on a single export drum. Finished lengths contain zero mid-length factory splices or repair patches. Exact continuous length and tolerance are confirmed on the order specification.
Does coastal salt fog, rain, or hydraulic oil damage 6.6 kV F-3PNCT in port service?
Tinned annealed copper conductors resist coastal salt corrosion. Meanwhile, the black polychloroprene (CR) outer sheath resists salt spray, humidity, UV exposure, crane oil mist, and roller wear. Buyers should still declare unusual chemical media upfront and install sealed waterproof terminations.
Can buyers inspect finished cables and 17 kV AC test results before paying the balance?
Yes. After production finishes, TEBAOFLEX sends finished-cable photos, factory videos, meter marks, sheath printing photos, and drum details before balance payment. We also issue the routine factory test report (17 kV AC / 10 min, resistance, and dimensions) and welcome third-party or on-site inspection.