Mine roadway & tunnel wall hangers
Primary duty — roadway arch suspension for underground conveyor pull-wire, telemetry and comms.
Product
320/550 V (BS 6708) 4-core (Type 70) and 5-core (Type 71) × 4 mm² pliable wire-armoured mining cables for coalface lighting, signalling and control, with EPR core insulation, 2.0 mm rubber inner sheath, 7/0.45 mm galvanized steel armour and 2.5 mm PCP sheath.
Typical values for this cable type, based on BS 6708 — confirmed in the datasheet and quotation for your order.
Application fit
Pliable wire-armoured multipair/multicore underground mine signalling, telephone and pilot interlock cable to BS 6708 Type 70 & Type 71.
Primary duty — roadway arch suspension for underground conveyor pull-wire, telemetry and comms.
Crush-resistant armoured control runs in shafts, pump lodges and underground switchgear rooms.
Allows periodic extension and repositioning with advancing gate-road pantechnicons.
Pliable steel armour is for static/flitted roadway runs, not dynamic reeling drums.
Use Longwall Signal CableArmoured construction cannot flex inside energy chains.
Use (N)GRDGCGÖU ChainConstruction
Four (Type 70) or five (Type 71) unscreened 4 mm² (56/0.30 mm) Class 5 tinned copper conductors, each insulated with 1.0 mm EPR and wrapped with coloured textile identification tape, are laid up in contact with each other around an elastomeric cradle, enclosed in a 2.0 mm rubber inner sheath (Ø 15.8 to 19.2 mm), armoured with 7/0.45 mm galvanized steel pliable wire armour and protected by a 2.5 mm heavy-duty black chloroprene (PCP) outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | 4 mm² flexible conductors | Electrolytic stranded tinned copper wire, IEC 60228 Class 5 (56/0.30 mm, Ø 2.60 mm)IEC 60228 Class 5 |
| 2 | Core insulation | EPR (ethylene-propylene rubber), 1.0 mm nominal radial thicknessBS 7655 / BS 6708 |
| 3 | Identification tape | Coloured textile tape applied over EPR insulation for core identificationCore identification |
| 4 | Elastomeric cradle | Central elastomeric cradle around which the cores are laid up in contactCradle centre |
| 5 | Inner sheath | Extruded rubber inner sheath (2.0 mm radial thickness; Ø 15.8–17.8 mm on Type 70, Ø 17.2–19.2 mm on Type 71)2.0 mm rubber inner sheath |
| 6 | Pliable wire armour (PWA) | Galvanized steel 7/0.45 mm pliable wire armour (≤ 5.07 Ω/km on Type 70; ≤ 4.63 Ω/km on Type 71 at 20 °C)7/0.45 mm PWA |
| 7 | Outer sheath | Heavy-duty flame-retardant polychloroprene (chloroprene / PCP) outer sheath, black (2.5 mm radial thickness)BS 6708 / BS 7655 EM2 |
4 unscreened 4 mm² EPR cores + 2.0 mm rubber inner sheath + 7/0.45 mm galvanized steel PWA + 2.5 mm PCP sheath (23.5–26.0 mm OD)
5 unscreened 4 mm² EPR cores + 2.0 mm rubber inner sheath + 7/0.45 mm galvanized steel PWA + 2.5 mm PCP sheath (24.9–27.4 mm OD)
Technical data
Sizes
Complete dimensional, armour, pulling tension, weight, current rating and DC resistance data.
| Type · nominal CSA mm² | Conductor stranding | Cond. Ø mm | EPR insul. mm | Inner sh. mm | Inner sh. Ø mm | Armour strand | Outer sh. mm | Min. OD mm | Max. OD mm | Min. R mm | Max. pull kgf | Mass ≈ kg/km | Cu wt kg/km | Current (25 °C) A | Cond. DC res. Ω/km | Armour DC res. Ω/km | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type 70 · 4×4 | 56/0.30 | 2.60 | 1.0 | 2.0 | 15.8–17.8 | 7/0.45 | 2.5 | 23.5 | 26.0 | 234 | 96 | 1,100 | 154 | 28 | 5.09 | 5.07 | |
| Type 71 · 5×4 | 56/0.30 | 2.60 | 1.0 | 2.0 | 17.2–19.2 | 7/0.45 | 2.5 | 24.9 | 27.4 | 247 | 100 | 1,230 | 192 | 28 | 5.09 | 4.63 |
Reel check
A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 1.5 kV AC applied between cores and between cores and pliable wire armour | Every drum |
| Conductor & armour DC resistance check | ≤ 5.09 Ω/km conductor; ≤ 5.07 Ω/km (Type 70) / ≤ 4.63 Ω/km (Type 71) armour at 20 °C | Every drum |
| Sample tests | ||
| Flame retardance test | Self-extinguishing heavy-duty chloroprene outer sheath per BS 6708 / BS EN 60332-1-2 | Production batch |
| Armour & sheath wall inspection | Verification of 2.0 mm rubber inner sheath, 7/0.45 mm galvanized steel armour and 2.5 mm PCP outer sheath | Every drum |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.