Trailing & towing
Engineered for heavy-duty mobile mining and industrial trailing duty per BS 6708 Type 830 / BS EN 60228.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per BS 6708 Type 830 / BS EN 60228 across -25 to +90 °C.
Typical values for this cable type, based on BS 6708 Type 830 / BS EN 60228 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per BS 6708 Type 830 / BS EN 60228 across -25 to +90 °C.
Engineered for heavy-duty mobile mining and industrial trailing duty per BS 6708 Type 830 / BS EN 60228.
Suitable for underground coal/hard-rock roadways, shuttle cars and quarry feeders (-25 to +90 °C).
Can be installed on cable trays, hangers and mobile skid interconnections within 10 × OD.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: BS 6708 Type 830 (BS 6708 Type 830 / BS EN 60228) featuring phase conductors (3×120 mm²), 6.35/11 kv epr insulation (7.5 mm) and heavy-duty outer sheath (pcp) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×120 mm²) | IEC 60228 Class 5 flexible annealed tinned copper + semicon screen |
| 2 | 6.35/11 kV EPR Insulation (7.5 mm) | Thick high-dielectric EPR phase insulation (Red, Yellow & Brown) |
| 3 | Composite Phase Braid Screen | Tinned copper wire and nylon fibre composite braid over each core |
| 4 | Central Earth Conductor (1×16 mm²) | Uninsulated flexible tinned copper conductor in central interstice |
| 5 | Heavy-Duty Outer Sheath (PCP) | Black tear-, oil- and weather-resistant polychloroprene rubber sheath |
Built to BS 6708 Type 830 / BS EN 60228 with phase conductors (3×120 mm²) and heavy-duty outer sheath (pcp)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to BS 6708 Type 830 / BS EN 60228 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BS 6708 Type 830 Construction Schedule (-25 to +90 °C) | |||||||
| BS 6708 Type 830 3×95 + 1×16 mm² | 3 × 95 mm² + 1 × 16 mm² (E) | Class 5 tinned Cu | 71.5 | 7,450 | 42.5 | 715 | |
| BS 6708 Type 830 3×120 + 1×16 mm² | 3 × 120 mm² + 1 × 16 mm² (E) | Class 5 tinned Cu | 75.8 | 8,620 | 54.0 | 760 | |
| BS 6708 Type 830 3×150 + 1×25 mm² | 3 × 150 mm² + 1 × 25 mm² (E) | Class 5 tinned Cu | 81.2 | 10,180 | 67.5 | 815 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 95 mm² + 1 × 16 mm² (E) | 0.21 | 6.35/11 kV (265 A) | -25 to +90 °C |
| 3 × 120 mm² + 1 × 16 mm² (E) | 0.16 | 6.35/11 kV (305 A) | -25 to +90 °C |
| 3 × 150 mm² + 1 × 25 mm² (E) | 0.13 | 6.35/11 kV (350 A) | -25 to +90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 6708 Type 830 / BS EN 60228) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 6708 Type 830 / BS EN 60228 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 6708 Type 830 / BS EN 60228) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (BS 6708 Type 830 / BS EN 60228) | Verified flame retardancy, mechanical integrity and thermal endurance across -25 to +90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.