Control & signal cablesDIN VDE 0285U0/U 300/500 VSteel Wire Braid GSWB

SY / YSLYSY Steel Wire Braided Control Cable300/500 V galvanised steel-wire-braided (GSWB) armoured flexible PVC control cable

Mechanically armoured 300/500 V flexible PVC control cable (SY / YSLYSY) with Class 5 copper conductors, numbered TI2 PVC cores, grey PVC inner bedding, galvanised steel wire braid armour (GSWB) and a transparent PVC oversheath.

EMC screen
Flame-retardant
Oil-resistant
Approved
Order designation
YSLYSY-JZ 5G2.5
Outer Ø min
11.0 mm
Outer Ø max
12.0 mm
Weight ≈
272 kg/km
Min. bend R
72 mm
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
U0/U · 4.0 kV AC test voltage
Armour braid
Galv. steel GSWB
High crush, cut & swarf protection
Temp. flexing
−5…+70 °C
−40…+80 °C fixed installation
Bending radius
6–12.5 × OD
6 × OD fixed · 12.5 × OD flexing
Outer sheath
Transparent PVC
Allows visual inspection of GSWB
Size range
0.75–25 mm²
2 to 34 cores · JZ or OZ coding

Typical values for this cable type, based on DIN VDE 0285 / BS EN 50525-2-51 — confirmed in the datasheet and quotation for your order.

Application fit

Is SY / YSLYSY right for your machine?

SY / YSLYSY is built for machine-shop floors, metalworking lathes, bottling plants and heavy factory installations where hot metal swarf, foot traffic or abrasion would cut an unarmoured YY cable, while retaining Class 5 flexibility.

Fixed installation

Suitable

Exposed machine-tool drop leads, metalworking conveyors, foundry auxiliaries and industrial plant floors.

Trailing & towing

With conditions

Handles flexing and repositioning under mechanical stress, but not high-tension reeling.

Use S07BQ-F Reinforced

Energy chain / drag chain

Not suitable

Galvanised steel wire braid is for mechanical armouring, not continuous drag-chain cycling.

Use JZ-500-PUR

VFD inverter to AC motor screened feeder

Not suitable

Steel wire braid has higher high-frequency impedance than copper; use CY / YSLCY for EMC shielding.

Use CY / YSLCY Screened
Typical machinesMetalworking lathes, mills & pressesAutomotive body-in-white & stampingConveyors, warehouses & plant floorsBottling, canning & brewery linesHeavy plant & hydraulic power packs

Construction

Layer by layer

Shown: SY / YSLYSY-JZ 5G2.5 — Class 5 bare copper conductors, white-numbered black PVC cores + green-yellow earth, grey PVC inner bedding, galvanised steel wire braid (GSWB) and transparent TM2 PVC oversheath.

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible copper conductorFine-stranded bare copper wire to IEC 60228 / DIN VDE 0295 Class 5IEC 60228 Class 5
2PVC core insulationSpecial polyvinyl chloride compound Type TI2 with white numbersEN 50363-3 TI2 · EN 50334
3PVC inner beddingExtruded grey polyvinyl chloride inner sheath isolating cores from the steel wire braidDIN VDE 0207-5 YM2
4Galvanised steel wire braidInterwoven galvanised steel wire braid (GSWB) providing mechanical crush, cut and rodent protectionMechanical armour braid
5Transparent PVC oversheathFlame-retardant and oil-resistant transparent polyvinyl chloride compound Type TM2EN 50363-4-1 TM2 · IEC 60332-1-2

YSLYSY-JZ / SY-JZ (3G–34G)

Black white-numbered PVC cores + 1 green-yellow earth + grey inner sheath + GSWB + transparent PVC sheath

YSLYSY-OZ / SY-OZ (2×–5×)

Black white-numbered PVC cores without earth + grey inner sheath + GSWB + transparent PVC sheath

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0285 / BS EN 50525-2-51. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
300/500 V AC
AC test voltage
4000 V AC (50 Hz, 5 min)
Insulation resistance
≥ 20 MΩ·km at +20 °C
Conductor stranding
IEC 60228 / DIN VDE 0295 Class 5 bare copper
Protective earth note
Always use the internal GN/YE copper core as the primary protective earth

Thermal

Temperature, flexing
−5 °C to +70 °C
Temperature, fixed
−40 °C to +80 °C
Max. conductor temperature
+70 °C (+80 °C fixed) continuous operation
Short-circuit temperature
+160 °C max. (up to 5 s)

Mechanical

Min. bending radius, fixed
6 × overall diameter
Min. bending radius, flexing
12.5 × overall diameter
Mechanical protection
Galvanised steel wire braid (GSWB) resists swarf, crushing & tension
Gland termination
Terminate with brass CW/SY mechanical armour clamping glands

Resistance

Flame retardance
IEC 60332-1-2 / EN 60332-1-2 self-extinguishing · CPR Eca
Oil & coolant resistance
Transparent PVC oversheath protects steel braid from oil & corrosion
Visual inspection
Clear outer jacket allows instant visual check of steel braid integrity

Reference standards

Construction basis
DIN VDE 0285-525-2-51 / BS EN 50525-2-51 / VDE 0245
Conductor standard
IEC 60228 / EN 60228 Class 5
Core identification
DIN VDE 0293-308 / EN 50334
RoHS & REACH
2011/65/EU (RoHS 2) & EC 1907/2006 compliant

Identification

Inner / outer sheath colour
Grey inner bedding + transparent clear PVC outer sheath
Core identification
Black cores with white numbers + GN/YE (JZ) or without GN/YE (OZ)
Sheath marking
TEBAOFLEX SY / YSLYSY-JZ [Size] 300/500V GSWB CONTROL CABLE CE
Customs tariff (HS)
8544.49 (insulated conductors ≤ 1000 V)

Sizes

23 standard SY / YSLYSY configurations

Typical DIN VDE 0285 / BS EN 50525-2-51 outer diameter limits, copper content and cable weight.

Dimensions & weights
Order designationCores × mm²AWG ≈Outer Ø min
mm
Outer Ø max
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
mm
Enquiry
0.75 mm² Steel-Braided Control Configurations (3 to 12 cores)
YSLYSY-JZ 3G0.753G0.75186.87.4228644
YSLYSY-JZ 4G0.754G0.75187.37.92910247
YSLYSY-JZ 5G0.755G0.75187.88.53612151
YSLYSY-JZ 7G0.757G0.75188.59.25014855
YSLYSY-JZ 12G0.7512G0.751810.711.68623270
1.0 mm² Steel-Braided Control Configurations (3 to 12 cores)
YSLYSY-JZ 3G1.03G1.0177.17.7299846
YSLYSY-JZ 4G1.04G1.0177.58.23811849
YSLYSY-JZ 5G1.05G1.0178.28.94814053
YSLYSY-JZ 7G1.07G1.0179.09.86717859
YSLYSY-JZ 12G1.012G1.01711.212.211527573
1.5 mm² Steel-Braided Control Configurations (3 to 18 cores)
YSLYSY-JZ 3G1.53G1.5167.88.54312551
YSLYSY-JZ 4G1.54G1.5168.49.15815255
YSLYSY-JZ 5G1.55G1.5169.210.07218460
YSLYSY-JZ 7G1.57G1.51610.010.910123565
YSLYSY-JZ 12G1.512G1.51612.813.917337283
YSLYSY-JZ 18G1.518G1.51614.916.225952097
2.5–16 mm² Steel-Braided Control & Machine Feeders
YSLYSY-JZ 3G2.53G2.5149.210.07218260
YSLYSY-JZ 4G2.54G2.51410.010.99622465
YSLYSY-JZ 5G2.55G2.51411.012.012027272
YSLYSY-JZ 4G44G41211.812.815433577
YSLYSY-JZ 4G64G61013.414.623046588
YSLYSY-JZ 4G104G10816.718.2384735109
YSLYSY-JZ 4G164G16619.921.66141,080130
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are typical values per DIN VDE 0285 / BS EN 50525-2-51. Minimum fixed bending radius shown is 6 × OD.

Reel check

Will it fit your machine?

A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.

Check results

Drum core 300 mm ≥ 144 mmBending radius OK (6 × OD 12.0 mm)
Minimum bending radius
72 mm
Min. drum core diameter
≈ 144 mm
Cable weight on drum
13.6 kg
Copper content
6.0 kg
Indicative only: based on the datasheet outer diameter and 6 × OD bending radius. Current derating for wound layers per DIN VDE 0298-4 is assessed separately.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC voltage test4.0 kV AC (50 Hz)Every manufactured length
Conductor DC resistanceIEC 60228 / DIN VDE 0285 / BS EN 50525-2-51 (bare copper)Every manufactured length
Sample tests
Vertical flame propagationIEC 60332-1-2 / EN 60332-1-2Per production batch
Insulation & sheath material physical propertiesDIN VDE 0285 / BS EN 50525-2-51Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0285 / BS EN 50525-2-51CE · RoHS 2 (2011/65/EU) · REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SY / YSLYSY-JZ [Size] 300/500 V GSWB CONTROL CABLE CE
Delivery form
Export wooden drums or coils, cut-to-length on request
Packaging
Heat-treated ISPM-15 timber drums with sealed cable ends
Conductor / sheath options
Custom core counts, pair counts or sheath colours on request

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What does the 'SY' or 'YSLYSY' cable designation mean?
In German VDE / European cable codes, YSLYSY (commonly called 'SY') denotes a PVC-insulated ('Y'), special control ('SL'), PVC inner-bedded ('Y'), galvanised steel-wire-braided ('S' = Stahldrahtgeflecht) and transparent PVC oversheathed ('Y') flexible control cable.
Why does SY / YSLYSY have both an inner grey sheath and a clear outer sheath?
The extruded grey PVC inner bedding cushions the insulated cores against the steel wires so the braid cannot abrade the core insulation during flexing, while the transparent PVC outer sheath seals the galvanised steel braid against cutting fluids, moisture and corrosion while leaving the armour visible for inspection.
Can the galvanised steel wire braid (GSWB) be used as the sole protective earth conductor?
No. Under BS 7671 and DIN VDE 0100, the galvanised steel wire braid on SY cables is a mechanical armour layer rather than a primary protective conductor. Always select the '-JZ' version and use the internal green-yellow copper core as the circuit protective conductor (CPC), earthing the steel braid at the gland for supplementary fault protection.
How does SY compare with SWA (Steel Wire Armoured) cable?
Traditional BS 5467 SWA cable uses rigid Class 2 conductors and heavy single round steel wires for fixed underground burial. SY / YSLYSY uses fine-stranded Class 5 copper and a flexible woven steel wire braid, allowing tight routing onto vibrating machine tools and workshop drops.

Request a quote

Get an engineering quote for SY / YSLYSY

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SY / YSLYSY Steel Wire Braided Control Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote