Contact

Project case · Sultanate of Oman

Case Study: 5 kV 200 °C 1x150 mm² Dual-Layer Silicone Rubber Motor Lead Cable for Heavy Motor Overhaul in Oman

How TEBAOFLEX engineered 5 kV 200 °C 1x150 mm² yellow-white dual-layer cross-linked silicone rubber motor lead cable for a heavy motor overhaul in Oman.

JyenOperations & Technical Engineer4 images
Heavy industrial electric motor in Oman with 5 kV 200 °C 1x150 mm² white silicone rubber stator leads and crimp lugs
Location
Sultanate of Oman
Application
Heavy-duty medium-voltage industrial and traction motor stator leads
Evidence
4 images
In this case15 sections
  1. 011. Project Context: Heavy Motor Rewind Duty in High-Ambient Oman Service
  2. 022. Why Did the Oman Rewind Shop Specify Dual-Layer 5 kV 200 °C Silicone Rubber at 150 mm²?
  3. 3 kV to 7 kV 200 °C Silicone Motor Lead Table (16 mm² to 240 mm²)
  4. 033. Inside the 5 kV 200 °C 1x150 mm² Dual-Layer Silicone Cable Architecture and TEBAOFLEX Product Range
  5. Four-Layer Construction & Pre-Shipment Inspection Breakdown
  6. Thermal Ampacity Scaling and Short-Run Voltage Drop Verification
  7. Comparing TEBAOFLEX High-Temperature Motor Lead & Rolling-Stock Cable Series
  8. 044. Field Installation Feedback from Oman: Compression Glands, Bend Radius, and Export Drum Protection
  9. 055. Pre-Order Specification Checklist for 3 kV to 7 kV High-Temperature Motor Lead Buyers
  10. 06Frequently Asked Questions
  11. What is the difference between 5 kV 200 °C dual-layer silicone motor lead cable and standard UL 3231 SRML wire?
  12. Why does the 5 kV 200 °C 1x150 mm² cable use a yellow inner insulation and a white outer sheath?
  13. Can TEBAOFLEX manufacture non-standard cut lengths on 150 mm² 5 kV silicone motor lead cables?
  14. What temperature range does the cross-linked silicone rubber insulation and sheath withstand?
  15. How does the 26.15 mm nominal outer diameter of the 5 kV 1x150 mm² cable affect gland and lug selection?

Case at a glance

Location
Sultanate of Oman
Application
Heavy-duty medium-voltage industrial and traction motor stator leads
Cable type
5 kV 200 °C 1x150 mm² dual-layer cross-linked silicone rubber motor lead cable →
Evidence
4 images

TL;DR: An Oman motor shop needed 5 kV 200 °C 1x150 mm² silicone leads (European dual-layer class). Standard UL 3231 SRML wires stop at 1,000 V, while BS EN 50382-2 cables stop at 150 °C. TEBAOFLEX built a custom 1C x 150 mm² Class 5 copper cable with a 2.00 mm yellow silicone inner wall and a 1.90 mm white silicone outer sheath (26.15 mm OD). Shipped on a batten-sealed wooden drum (74 x 74 x 70 cm, 108 kg), the leads sealed cleanly into the rebuilt traction motor glands.

  • Project Location: Sultanate of Oman (Industrial rotating machinery & traction motor overhaul workshop).
  • Target Equipment: Heavy-duty medium-voltage industrial / traction electric motor internal stator-to-terminal leads.
  • Reference Spec: 5 kV 200 °C (European heavy-wall dual-layer profile) single-core motor lead cable (1C x 150 mm²).
  • Conductor Design: 150 mm² fine-stranded annealed bare electrolytic copper (IEC 60228 Class 5 / flexible stranding) + non-hygroscopic polyester separator tape.
  • Dual-Layer Silicone Wall: 2.00 mm yellow cross-linked silicone rubber insulation + 1.90 mm white cross-linked silicone rubber outer sheath.
  • Nominal Dimensions: 26.15 mm nominal outer diameter (OD); 1,739 kg/km nominal unit cable weight.
  • Operating Thermal Window: -70 °C cold flexibility up to +200 °C continuous thermal stability (IEC 60085 Class N 200 °C).
  • Sheath Marking & Packing: TEBAOFLEX 5kV 200 °C SILICONE CABLE 1CX150mm² + meter marks; batten-closed wooden drum (74 x 74 x 70 cm, 108 kg).

1. Project Context: Heavy Motor Rewind Duty in High-Ambient Oman Service

Medium-voltage silicone rubber motor lead cable is a flexible single-core stator wire rated for 3 kV to 7 kV at 200 °C. It carries high phase currents from internal coil end-turns through the machine frame gland to the main terminal box. During a motor rewind, this internal lead endures intense heat, electrical stress, and tight bending.

In Oman, heavy motors driving oilfield rigs, desert traction drives, cement fans, and port cranes run in 45 °C to 55 °C summer shade heat. Inside an enclosed motor frame, copper stator windings rated to IEC 60085:2007 Electrical Insulation Thermal Classification Class H (180 °C) or Class N (200 °C) radiate extreme heat onto outgoing stator leads.

An Omani motor repair workshop took in a heavy yellow-framed traction motor for a full stator rewind. Their engineers needed an exact replacement for the motor's original 5 kV 200 °C 1x150 mm² white silicone leads. Standard 90 °C XLPE or EPR power cables built for external feeders under IEC 60034-1 Rotating Electrical Machines Rating Standard cannot survive inside Class H or Class N housings. They harden and crack under 180 °C to 200 °C end-turn heat and vacuum-pressure impregnation (VPI) oven cycles.

Across our high-temperature wire and cable portfolio, cross-linked silicone rubber (SiR) is the top choice for 150 mm² stator leads. It bends smoothly inside tight motor frames while running continuously at 200 °C.

2. Why Did the Oman Rewind Shop Specify Dual-Layer 5 kV 200 °C Silicone Rubber at 150 mm²?

Sourcing a 5 kV 200 °C 1x150 mm² motor lead cable exposes a gap in standard catalog stock. Most off-the-shelf high-temperature cables miss on voltage rating, temperature ceiling, or jacket texture.

  1. North American SRML / UL 3231 motor lead wires. These wires handle 200 °C, but UL 758 caps their voltage rating at 600 V or 1,000 V. Their outer fiberglass braid can also fray or let dust bypass a compression cable gland.
  2. European BS EN 50382-2 rolling-stock power cables. These cables cover 1.8/3 kV and 3.6/6 kV at 150 mm². However, BS EN 50382-2:2008+A1:2013 Rolling Stock Silicone Power Cable Standard limits continuous conductor temperature to 120 °C or 150 °C instead of 200 °C.
  3. Standard 1.1 kV or 3 kV panel leads. Thin-wall leads lack the 3.90 mm radial silicone barrier needed to block corona discharge where a 5 kV lead passes through grounded steel glands.
High-voltage electric motor stator core and copper coil end-turns during workshop rewind inspection prior to connecting flexible stator lead cables

High-voltage electric motor stator core and copper coil end-turns during workshop rewind inspection prior to connecting flexible stator lead cables.

To fit the motor's existing stainless cable glands and terminal lugs without machining the housing, the Omani workshop needed the exact European 5 kV 200 °C dual-layer geometry.

Dual-layer color-contrasted silicone extrusion is a medium-voltage motor lead construction that pairs a yellow inner cross-linked silicone insulation wall with a white outer cross-linked silicone sheath. This two-layer design solves two shop-floor problems. First, dividing the 3.90 mm total barrier into a 2.00 mm inner layer and a 1.90 mm outer sheath prevents micro-pinholes from aligning across the wall. Second, if a sharp frame edge scrapes the white outer jacket during assembly, the bright yellow inner layer warns technicians immediately before copper strands are exposed.

3 kV to 7 kV 200 °C Silicone Motor Lead Table (16 mm² to 240 mm²)

Rewind engineers must match wall thickness and OD to gland bores. The table below compares key cross-sections across all three voltage classes, highlighting the 5 kV 1x150 mm² Oman build.

  • 16 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 11.40 mm / 237 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 13.00 mm / 274 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 14.60 mm / 315.
  • 35 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 14.90 mm / 465 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 16.50 mm / 512 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 18.10 mm / 564.
  • 70 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 18.70 mm / 833 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 20.30 mm / 892 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 21.90 mm / 955.
  • 95 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 20.90 mm / 1,107 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 22.50 mm / 1,172 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 24.10 mm / 1,241.
  • 120 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 22.60 mm / 1,351 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 24.20 mm / 1,421 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 25.80 mm / 1,495.
  • 150 mm² (Oman Order): 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 24.55 mm / 1,664 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 26.15 mm / 1,739 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 27.75 mm / 1,820.
  • 185 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 27.40 mm / 2,047 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 29.00 mm / 2,131 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 30.60 mm / 2,220.
  • 240 mm²: 3 kV Insul. / Sheath (mm): 1.50 / 1.60 | 3 kV Nom. OD (mm) & Mass (kg/km): 29.30 mm / 2,514 | 5 kV Insul. / Sheath (mm): 2.00 / 1.90 | 5 kV Nom. OD (mm) & Mass (kg/km): 30.90 mm / 2,604 | 7 kV Insul. / Sheath (mm): 2.50 / 2.20 | 7 kV Nom. OD (mm) & Mass (kg/km): 32.50 mm / 2,699.

3. Inside the 5 kV 200 °C 1x150 mm² Dual-Layer Silicone Cable Architecture and TEBAOFLEX Product Range

Building a 150 mm² single-core silicone cable that coils easily by hand requires short copper lay lengths and balanced peroxide curing.

Fine-stranded Class 5 electrolytic copper conductor is a multi-bundle flexible wire construction defined under IEC 60228:2023 Conductors of Insulated Cables. For 150 mm² plain copper, individual wire filaments stay at or below 0.50 mm diameter and 20 °C DC resistance stays at or below 0.129 Ohm/km. Upgrading from stiffer Class 4 stranding to fine rope-lay Class 5 stranding reduces bending torque on motor terminal studs.

TEBAOFLEX 5 kV 200 °C 1x150 mm² high-temperature motor lead cable macro cross-section showing fine-stranded copper core, 2.00 mm yellow silicone insulation, and 1.90 mm white silicone outer sheath

TEBAOFLEX 5 kV 200 °C 1x150 mm² high-temperature motor lead cable macro cross-section showing fine-stranded copper core, 2.00 mm yellow silicone insulation, and 1.90 mm white silicone outer sheath.

Four-Layer Construction & Pre-Shipment Inspection Breakdown

  • 1. Conductor: Component & Material Specification: 150 mm² soft annealed bare electrolytic copper, fine multi-bundle rope-lay stranding (IEC 60228) | Engineering Function in 5 kV 200 °C Motor Lead Service: Carries high stator phase current (<= 0.129 Ohm/km at 20 °C) while bending cleanly into crimp lugs.
  • 2. Separator Tape: Component & Material Specification: Helical non-hygroscopic polyester (PET) separator tape over the copper core | Engineering Function in 5 kV 200 °C Motor Lead Service: Prevents uncured silicone compound from penetrating between fine copper strands so lugs strip cleanly.
  • 3. Inner Insulation: Component & Material Specification: 2.00 mm radial wall cross-linked silicone rubber (Yellow pigment, 200 °C thermal stability) | Engineering Function in 5 kV 200 °C Motor Lead Service: Provides primary 5 kV dielectric strength, corona resistance, and visual wear-depth indication.
  • 4. Outer Sheath: Component & Material Specification: 1.90 mm radial wall cross-linked silicone rubber (White compound, -70 °C to +200 °C) | Engineering Function in 5 kV 200 °C Motor Lead Service: Resists ozone, lubricating greases, moisture, and compression-gland clamping without fiberglass fray.

Thermal Ampacity Scaling and Short-Run Voltage Drop Verification

Why does a 150 mm² 200 °C silicone lead carry full motor current inside an 80 °C housing where a 90 °C XLPE cable overheats? Under steady-state thermal rules (IEC 60287, 2023), ampacity scales with the temperature rise window (T_max - T_amb).

  • K_temp = sqrt( (T_max - T_amb) / (T_max - 40) )
  • R_200 = R_20 * [ 1 + 0.00393 * (200 - 20) ] = 1.707 * R_20

At an internal housing ambient of T_amb = 80 °C, a 90 °C XLPE cable retains only 0.45 (45%) of its 40 °C base ampacity (IEC 60287, 2023). By contrast, a 200 °C silicone cable retains 0.87 (87%) of its 40 °C rating (IEC 60085, 2007). Even at a 200 °C conductor temperature (R_200 = 0.220 Ohm/km), a 5 m lead at 350 A drops just 0.39 V (135 W or 0.135 kW per lead).

Before packing, every meter of the white silicone sheath received clear black inkjet marking (TEBAOFLEX 5kV 200 °C SILICONE CABLE 1CX150mm² 01M ... 37M). Our quality team verified minimum and average wall thicknesses, AC dielectric withstand, continuity, and 20 °C DC resistance on the outgoing inspection record.

TEBAOFLEX 5 kV 200 °C 1Cx150 mm² white cross-linked silicone rubber cable wound on export wooden drum with end cap and sequential meter markings

TEBAOFLEX 5 kV 200 °C 1Cx150 mm² white cross-linked silicone rubber cable wound on export wooden drum with end cap and sequential meter markings.

Comparing TEBAOFLEX High-Temperature Motor Lead & Rolling-Stock Cable Series

Different motor frames call for either smooth silicone sheaths or braided glass armor. You can compare both options in our guide on why fiberglass-braided silicone cables use high-temperature varnish impregnation and our overview of 180 °C to 450 °C high-temperature wire insulation types.

  • Custom 3 kV / 5 kV / 7 kV Dual-Layer Silicone Motor Lead (European Dual-Layer Class): Voltage & Thermal Rating: 3 kV, 5 kV, 7 kV; -70 °C to +200 °C (1.0 to 240 mm²) | Insulation & Jacket Architecture: Bare/tinned flexible Cu + PET tape + yellow cross-linked SiR + white cross-linked SiR sheath | Primary Motor / Equipment Application: Medium-voltage traction motors, industrial synchronous/induction motor stators, compression gland entries.
  • Silicone Rubber Motor Lead Wire (SRML / UL 3231 & UL 3070): Voltage & Thermal Rating: 600 V / 1,000 V; -60 °C to +150 °C / +200 °C (24 AWG to 4/0 AWG) | Insulation & Jacket Architecture: Flexible tinned Cu (ASTM B33) + vulcanized SiR + varnish-compatible treated fiberglass braid | Primary Motor / Equipment Application: Low-voltage Class F, H & N motor stators, dry-type VPI transformers, generator coil leads.
  • EN 50382-2 High-Temperature Rolling Stock Power Cable: Voltage & Thermal Rating: 1.8/3 kV & 3.6/6 kV AC; -50 °C to +120 °C / +150 °C (10 to 240 mm²) | Insulation & Jacket Architecture: Class 5/6 Cu + halogen-free silicone rubber (EN 45545-2 HL3 fire safety) | Primary Motor / Equipment Application: Railway locomotive bogies, metro traction inverters, high-speed train power jumpers.
  • Silicone Rubber Insulated High-Temperature Wire (H05S-K / H05SJ-K): Voltage & Thermal Rating: 300/500 V to 1,000 V; -60 °C to +180 °C / +200 °C | Insulation & Jacket Architecture: Fine-stranded tinned Cu + single-wall EI2 silicone rubber (with or without glass braid) | Primary Motor / Equipment Application: Internal cabinet wiring, furnace fan junction boxes, heating element connections.
  • 180 °C Silicone Pump Motor Lead Cable: Voltage & Thermal Rating: 600 V to 5 kV; -50 °C to +180 °C | Insulation & Jacket Architecture: Moisture- and heat-resistant silicone/fluoropolymer motor lead assembly | Primary Motor / Equipment Application: High-temperature industrial pumps, sealed motor housings, thermal fluid circulators.

4. Field Installation Feedback from Oman: Compression Glands, Bend Radius, and Export Drum Protection

After passing factory inspection in late August 2026, the 1C x 150 mm² cable was wound onto an export wooden drum with sealed end-caps. Our packing crew closed the drum perimeter with wooden battens and steel strapping (74 cm x 74 cm x 70 cm, 108 kg gross weight). Full batten protection stopped forklift blades from bruising the soft white silicone sheath during transit to Oman.

In October 2026, the Omani workshop finished rebuilding the yellow traction motor and shared installation photos of the installed TEBAOFLEX 5 kV 200 °C 1x150 mm² leads.

Drive-end view of rebuilt heavy industrial traction motor in Oman showing dual stainless compression cable glands and coiled white 5 kV 200 °C 1x150 mm² TEBAOFLEX silicone stator leads with crimped copper lugs

Drive-end view of rebuilt heavy industrial traction motor in Oman showing dual stainless compression cable glands and coiled white 5 kV 200 °C 1x150 mm² TEBAOFLEX silicone stator leads with crimped copper lugs.

Three field details stand out in the Oman workshop assembly:

  1. Tight Compression Gland Sealing on a Smooth 26.15 mm Sheath. Braided fiberglass leads (SRML) can leak dust or oil across rubber gland rings. By contrast, our smooth 26.15 mm white silicone outer sheath sealed evenly inside the motor's dual stainless steel cable glands.
  2. Compact Small-Radius Coiling Without Jacket Kinking. Conventional 150 mm² XLPE cables require a stiff 12 x OD to 15 x OD minimum bend radius. Rated down to a 5 x OD (~131 mm) minimum bend radius, our fine-stranded copper and dual-layer silicone cable coiled into a neat ~350 mm diameter loop (~175 mm / 6.7 x OD bend radius) right on the motor pallet.
  3. Clean Core Stripping and Heavy-Duty Copper Lug Termination. The internal PET separator tape kept cured silicone from sticking to the fine copper strands. Technicians stripped the 3.90 mm wall cleanly, crimped 150 mm² tinned copper lugs, and sealed the barrels with dual-wall heat-shrink tubing.

5. Pre-Order Specification Checklist for 3 kV to 7 kV High-Temperature Motor Lead Buyers

Before ordering stator leads for medium-voltage motors, traction drives, or transformers, check five technical details.

  1. Match voltage class (3 kV, 5 kV, or 7 kV) to wall thickness. Confirm whether your gland bore fits the 3 kV (1.50 + 1.60 mm), 5 kV (2.00 + 1.90 mm), or 7 kV (2.50 + 2.20 mm) dual-layer silicone schedule.
  2. Pick smooth silicone sheathing for compression glands. Use a smooth silicone outer sheath (heavy-wall dual-layer style) for stuffing glands, and reserve fiberglass-braided SRML / UL 3231 for internal VPI-laced coil leads.
  3. Verify bare versus tinned Class 5 copper stranding. Check whether your lug crimping spec or VPI varnish chemistry requires bare copper (European stator-lead baseline) or tinned copper (ASTM B33 / IEC 60228 Class 5).
  4. Require a polyester separator tape on sizes >= 50 mm². A non-hygroscopic PET tape stops silicone rubber from bonding to fine copper wires so 95 mm² to 240 mm² cores strip cleanly.
  5. Specify batten-enclosed wooden drums for export freight. Soft silicone sheaths need full wooden batten closure and end-caps to prevent handling cuts during ocean or air shipping.

Editorial & Engineering Note: All dimensional tables, thermal calculations, and factory inspection records in this case study were reviewed by TEBAOFLEX Jyen (Operations & High-Temperature Cable Engineering Desk). Explore our manufacturing and testing lines on our About TEBAOFLEX factory and laboratory page, or contact our engineering team with your motor voltage and gland bore size for a custom quotation.

Image credits: Workshop motor stator winding photo "Stator" by Elsie esq. via Flickr / Openverse (CC BY 2.0); Oman rebuilt traction motor field photos, cable cross-section, and export drum photos by TEBAOFLEX.

Frequently Asked Questions

What is the difference between 5 kV 200 °C dual-layer silicone motor lead cable and standard UL 3231 SRML wire?

Standard UL 3231 SRML wire is rated for 600 V or 1,000 V (UL 758) and uses a single silicone wall under a fiberglass braid. By contrast, our 5 kV 200 °C (heavy-wall dual-layer) cable pairs a 2.00 mm yellow silicone inner wall with a 1.90 mm smooth white silicone outer sheath (3.90 mm total wall). It delivers 5 kV dielectric strength and seals cleanly inside motor compression glands.

Why does the 5 kV 200 °C 1x150 mm² cable use a yellow inner insulation and a white outer sheath?

Extruding a 2.00 mm yellow inner silicone layer beneath a 1.90 mm white outer silicone sheath eliminates single-layer pinhole risk at 5 kV. It also provides a clear visual wear indicator. If a frame edge or gland thread scrapes the white outer jacket, the bright yellow inner layer shows up immediately before copper strands are exposed.

Can TEBAOFLEX manufacture non-standard cut lengths on 150 mm² 5 kV silicone motor lead cables?

Yes. Catalog distributors often demand high minimum order quantities on 120 mm² to 240 mm² medium-voltage silicone cables. Because TEBAOFLEX runs in-house copper stranding and silicone extrusion lines, we build project-specific lengths (such as the 37 m wooden drum lot supplied for this Oman overhaul) with sequential 01M meter marks.

What temperature range does the cross-linked silicone rubber insulation and sheath withstand?

The dual-layer cross-linked silicone elastomer construction runs continuously from -70 °C up to +200 °C (IEC 60085 Class N rating) without stiffening or cracking. It also resists ozone, moisture, and industrial lubricating greases inside heavy traction and oilfield motors.

How does the 26.15 mm nominal outer diameter of the 5 kV 1x150 mm² cable affect gland and lug selection?

A 26.15 mm nominal outer diameter fits standard M40 or 1-1/4 inch NPT compression cable glands (22 mm to 28 mm clamping range). Once the 3.90 mm silicone wall and PET separator tape are stripped, the 150 mm² Class 5 copper core fits standard 150 mm² flared-entry tubular crimp lugs (DIN 46235 / IEC 61238-1).

High-voltage electric motor stator core and copper coil end-turns during workshop rewind inspection prior to connecting flexible stator lead cables
TEBAOFLEX 5 kV 200 °C 1x150 mm² high-temperature motor lead cable cross-section showing fine-stranded copper core, 2.00 mm yellow silicone insulation, and 1.90 mm white silicone outer sheath
TEBAOFLEX 5 kV 200 °C 1Cx150 mm² white cross-linked silicone rubber cable wound on export wooden drum with end cap and sequential meter markings
Drive-end view of rebuilt heavy industrial traction motor in Oman showing dual stainless compression cable glands and coiled white 5 kV 200 °C 1x150 mm² TEBAOFLEX silicone stator leads

Specify it