DIN VDE 0250-812 / 813 mining trailing cablesDIN VDE 0250-813 Basis3.6/6 kV (Umax 7.2 kV)Weatherproof (W) · 3GI3 EPR

(N)TSW 3.6-6 kV Medium-Voltage Rubber Trailing CableDIN VDE 0250-813 3.6/6 kV weather-resistant (W) medium-voltage rubber trailing power cable

(N)TSW 3.6-6 kV is a weather-resistant (W = wetterfest) 3.6/6 kV (Umax 7.2 kV) medium-voltage rubber trailing power cable based on DIN VDE 0250-813, featuring Class 5 tinned copper conductors, 3GI3 EPR insulation with semi-conductive stress control, split

Ozone, UV & moisture
Oil-resistant
Flame-retardant
Water-resistant
Order designation
(N)TSW 3×50+3×25/3E 3.6/6 kV
Outer Ø ≈
45.5 mm
Copper weight
1,680 kg/km
Total weight ≈
3,090 kg/km
Min. bend R (fixed)
273 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
3.6/6 kV
Umax 7.2 kV AC 3-phase
Construction
3 Phase + 3E
Symmetrical split interstitial earth
Field control
Semicon Layers
Inner & outer semicon stress grading
Insulation
3GI3 MV EPR
+90 °C ozone-resistant EPR
Outer sheath
5GM3/5GM5 (W)
Weather, UV & oil-resistant PCP
Min. bend radius
6×D / 10×D
Fixed 6×D · trailing 10×D

Typical values for this cable type, based on DIN VDE 0250-813 — confirmed in the datasheet and quotation for your order.

Application fit

Is (N)TSW 3.6-6 kV right for your machine?

Designed for outdoor 3.6/6 kV quarry excavators, floating gravel and sand dredgers, mobile transformer stations, and surface-mine feeder connections.

Trailing & towing

Suitable

Weatherproof polychloroprene jacket endures ground dragging across quarry benches and gravel beds.

Immersion & wet locations

Suitable

Widely deployed on floating pontoon conveyors and wet gravel-pit suction dredgers.

Fixed installation

Suitable

Ideal for outdoor MV transformer skids, temporary site substations, and motor feeders.

Motorised monospiral reel

With conditions

Suitable for manual or slow festoon/take-up loops; for high-speed reeling use NTSCGEWÖU.

NTSCGEWÖU 3.6/6 kV

Mine roadway & tunnel wall hangers

With conditions

For underground coal faces requiring metallic phase screens specify NTSKCGECWÖU.

NTSKCGECWÖU 3.6/6 kV
Typical machinesSurface quarries & gravel pitsFloating sand & mineral dredgersOpen-cast mobile substationsHeavy construction & tunnel portals

Construction

Layer by layer

Three Class 5 tinned copper phase conductors with inner/outer semi-conductive field grading and 3GI3 EPR insulation, three symmetrical

123456
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase & split earth conductorsFinely stranded tinned copper, Class 5 per DIN EN 60228DIN EN 60228 Class 5
2Inner & outer field gradingVulcanised semi-conductive elastomeric stress-control layersDIN VDE 0250-813
3MV EPR insulation (3GI3)Cross-linked ethylene propylene rubber compound 3GI3 (3.6/6 kV)DIN VDE 0207-20
4Symmetrical 3+3E lay-up3 phase cores laid up with 3 split earth conductors in the outer intersticesDIN VDE 0250-813
5Inner sheathPressure-extruded elastomer inner bedding compound GM1bDIN VDE 0250-813
6Weatherproof outer sheath (W)Heavy-duty weather-, UV-, ozone- and oil-resistant polychloroprene 5GM3 / 5GM5DIN VDE 0207-21

(N)TSW 3×(16–185) + 3×E

3 phase cores + 3 symmetrical split protective earth conductors for 3.6/6 kV quarry & dredger service.

(N)TSW 3×(25–150) without PE

3-core 3.6/6 kV feeder configuration for ungrounded IT quarry distribution.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250-813. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
3.6/6 kV (Umax 7.2 kV)
AC routine test voltage
11 kV rms / 5 min
Max. operating DC voltage
5.4/9 kV DC
Insulation resistance @ 20 °C
≥ 500 MΩ·km

Thermal

Max. conductor operating temp.
+90 °C
Max. short-circuit temperature
+250 °C (5 s)
Ambient temperature (trailing)
-25 °C to +60 °C
Ambient temperature (fixed)
-40 °C to +80 °C

Mechanical

Max. tensile load on copper
15 N/mm²
Min. bending radius (fixed
6 × D fixed · 10 × D trailing
Torsional & impact resilience
Compact unarmoured rubber construction for

Resistance

Weather, UV & ozone resistance
DIN EN 60811-403 wetterfest (W) outdoor rated
Oil & grease resistance
DIN EN 60811-404 polychloroprene sheath
Flame retardancy
DIN EN 60332-1-2 self-extinguishing

Reference standards

Primary specification
DIN VDE 0250-813 ((N)TSW design)
Conductor standard
DIN EN 60228 Class 5 tinned copper
Compound standard
DIN VDE 0207-20 (3GI3) & 0207-21 (5GM3/5GM5)

Identification

Core coding
Numbered phase cores 1, 2, 3 + green/yellow
Outer sheath colour
Black or Red weather-resistant

Sizes

8 standard configurations ((N)TSW 3.6-6 kV)

Nominal dimensions, copper weights and electrical parameters for (N)TSW 3.6-6 kV per DIN VDE 0250-813.

Dimensions & weights
Order designationConfigurationPhase size mm²Outer Ø ≈
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
Standard (N)TSW 3.6-6 kV configurations
(N)TSW 3×16+3×16/3E 3.6/6 kV3×16 + 3×16/3E (3.6/6 kV)1634.56201,620207
(N)TSW 3×25+3×16/3E 3.6/6 kV3×25 + 3×16/3E (3.6/6 kV)2538.08802,010228
(N)TSW 3×35+3×16/3E 3.6/6 kV3×35 + 3×16/3E (3.6/6 kV)3541.21,1702,430247
(N)TSW 3×50+3×25/3E 3.6/6 kV3×50 + 3×25/3E (3.6/6 kV)5045.51,6803,090273
(N)TSW 3×70+3×35/3E 3.6/6 kV3×70 + 3×35/3E (3.6/6 kV)7050.22,3603,940301
(N)TSW 3×95+3×50/3E 3.6/6 kV3×95 + 3×50/3E (3.6/6 kV)9555.63,2605,040334
(N)TSW 3×120+3×70/3E 3.6/6 kV3×120 + 3×70/3E (3.6/6 kV)12060.24,1806,120361
(N)TSW 3×150+3×70/3E 3.6/6 kV3×150 + 3×70/3E (3.6/6 kV)15064.85,0407,190389
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Outer diameters and weights are nominal factory values subject to ±5 % manufacturing tolerance per DIN VDE 0250-813.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
11 kV AC voltage withstand11 kV rms / 5 min per DIN VDE 0250-813100 % of drums
Conductor DC resistanceComplies with DIN EN 60228 Class 5 at 20 °C100 % of drums
Sample tests
Ozone & weather ageing testDIN EN 60811-403 ozone resistance without crackingPer production batch
Flame & oil resistanceDIN EN 60332-1-2 & EN 60811-404Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250-813 BasisDIN EN 60332-1-2EN 10204 3.1

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX (N)TSW 3.6/6 kV VDE 0250-813 CE
Delivery form
Fumigated export wooden drums
Standard drum lengths
300 m · 500 m · 1000 m (or custom cut
MOQ
100 m (stock sizes) · 300 m (custom build)
Lead time
3–5 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What does the 'W' in (N)TSW 3.6-6 kV indicate?
'W' stands for wetterfest (weather-resistant) in the German VDE designation system. It denotes an ozone-, UV-, and moisture-stabilised heavy-duty polychloroprene rubber sheath designed for year-round outdoor trailing duty in quarries, gravel pits, and floating dredgers. Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and sheath dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.
How does (N)TSW 3.6-6 kV differ from NTSCGEWÖU 3.6/6 kV?
(N)TSW 3.6-6 kV uses semi-conductive field grading and three split interstitial protective earth conductors without individual metallic copper wire screens or high-speed drum anti-torsion braiding, making it lighter and simpler to terminate for semi-mobile quarry feeders and floating dredger pontoons. Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and sheath dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.
Can (N)TSW 3.6-6 kV be used on floating gravel and sand dredgers?
Yes. Floating suction and bucket-chain dredgers feeding 6 kV shore transformers are one of the primary applications for (N)TSW 3.6-6 kV, as its cross-linked 3GI3 EPR insulation and polychloroprene jacket tolerate continuous pontoon splashing and freshwater immersion. Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and sheath dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.
How is the protective earth arranged inside (N)TSW 3.6-6 kV?
Rather than using a single asymmetric fourth core, the protective earth is divided into three equal Class 5 tinned copper conductors positioned in the three outer interstices between the phase cores, preserving a circular cross-section and balanced impedance. Each production drum undergoes routine dielectric voltage testing, conductor DC resistance verification, and sheath dimensional inspection before dispatch with an EN 10204 3.1 mill test certificate.

Request a quote

Get an engineering quote for (N)TSW 3.6-6 kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

(N)TSW 3.6-6 kV Medium-Voltage Rubber Trailing Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote