Switchgear & control cabinet wiring
Compact 2.6–3.8 mm outer diameter routes densely inside ARINC 600 avionics racks and D38999 circular connectors.
Product
ARINC 429 Avionics Shielded Twisted-Pair Data Bus Cable is a 78 Ω ± 5 Ω aerospace twinax interconnect engineered to AEEC ARINC Specification 429 (Mark 33 Digital Information Transfer System / DITS) and MIL-DTL-27500. Operating from -55 °C to +200 °C, it
Typical values for this cable type, based on AEEC ARINC 429 / MIL-DTL-27500 / M17/176 — confirmed in the datasheet and quotation for your order.
Application fit
Primary avionics data bus linking flight management systems (FMS), air data inertial reference units (ADIRU), autopilot flight control computers, VHF/HF nav-comm radios, and cockpit EFIS displays
Compact 2.6–3.8 mm outer diameter routes densely inside ARINC 600 avionics racks and D38999 circular connectors.
UV-laser-markable ETFE/FEP jacket resists Skydrol hydraulic fluid, Jet-A fuel, and airframe vibration.
Fluoropolymer construction operates continuously from -55 °C at high altitude to +200 °C near engine bays.
Airframe twinax is designed for static harness bundles, not industrial drag chains.
S 369 C TPConstruction
2 × 19-strand (20, 22, 24, or 26 AWG) silver-plated copper or silver-plated high-strength copper alloy conductors (blue & white), solid or
| # | Layer | Material & reference |
|---|---|---|
| 1 | 19-strand SPC or Ag-Cu alloy twinax pair | 2 × 20, 22, 24, or 26 AWG (19-strand) silver-plated copper (ASTM B298) or high-strengthAS22759 / ARINC 429 |
| 2 | Low-loss fluoropolymer pair insulation | Extruded solid or cellular FEP / PTFE / crosslinked ETFE (Blue & White cores), mutualARINC 429 Pt 1 |
| 3 | 100 % foil screen + high-temp binder | Aluminised polyimide or fluoropolymer tape providing 100 % high-frequency HIRF MIL-DTL-27500 |
| 4 | Silver-plated copper wire braid shield | 38 AWG silver-plated copper braid (≥ 90 % coverage; double braid option for severe HIRFMIL-DTL-27500 |
| 5 | UV-laser-markable ETFE / FEP / PTFE | White (or colour-coded) crosslinked ETFE (+150/+200 °C), FEP (+200 °C), or sintered PTFEFAR 25.853 / ABD0031 |
Airframe weight-saving 24 AWG high-strength alloy twinax with 59 pF/m capacitance and laser-markable jacket.
Workhorse 22 AWG (19×34 SPC) 78 Ω twinax compatible with standard M39029 Size 8 twinax/coax contacts.
+200 °C PFA/PTFE 78 Ω twinax qualified for both 100 kbps ARINC 429 and 1 Mbps MIL-STD-1553B buses.
Technical data
Sizes
Dimensional, physical and high-frequency electrical parameters for ARINC 429 per AEEC ARINC 429 / MIL-DTL-27500 / M17/176.
| Order designation | Construction / Variant | Conductor | Outer Ø ≈ mm | Metal kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Standard ARINC 429 variants | |||||||
| ARINC 429 1×2×24 AWG Low-Cap Foam FEP | 78 Ω Pair + Foil + 90% SPC Braid | 24 AWG (19×36 Alloy) | 2.85 | 9.8 | 16.5 | 14 | |
| ARINC 429 1×2×22 AWG Standard FEP/ETFE | 78 Ω Pair + Foil + 90% SPC Braid | 22 AWG (19×34 SPC) | 3.25 | 14.5 | 23.8 | 16 | |
| ARINC 429 1×2×20 AWG Long-Run Twinax | 78 Ω Pair + Foil + 90% SPC Braid | 20 AWG (19×32 SPC) | 3.85 | 21.0 | 33.5 | 19 | |
| M17/176-00002 (1553B / ARINC 429 +200 °C) | 78 Ω Pair + SPC Braid (PFA) | 24 AWG (19×36 Alloy) | 3.28 | 11.2 | 22.3 | 16 | |
| Configuration | Max. conductor DC R Ω / km @ 20 °C | Characteristic Z₀ Ω | Capacitance pF / m | Velocity VoP % | Test voltage V rms |
|---|---|---|---|---|---|
| 78 Ω Pair + Foil + 90% SPC Braid | 1.5 | 78 | 48.0 | 72 | 1,500 |
| 78 Ω Pair + Foil + 90% SPC Braid | 1.6 | 78 | 48.0 | 72 | 1,500 |
| 78 Ω Pair + Foil + 90% SPC Braid | 1.7 | 78 | 48.0 | 72 | 1,500 |
| 78 Ω Pair + SPC Braid (PFA) | 1.5 | 78 | 48.0 | 72 | 1,500 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 100 % TDR characteristic impedance & capacitance | 78 Ω ± 5 Ω; mutual capacitance ≤ 98 pF/m (≤ 30 pF/ft) | Every spool |
| 1.5 kV rms AC dielectric & 3.0 kV spark test | Zero breakdown core-to-core and core-to-shield | 100 % of length |
| Sample tests | ||
| UV laser contrast & Skydrol fluid immersion | ≥ 85 % contrast ratio; zero jacket swelling in Skydrol LD-4 | Per batch |
| FAR 25.853 vertical burn, smoke & toxicity | Passes 60-second vertical bunsen burn and ABD0031 toxicity | Qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.