Fixed installation
Engineered and verified for fixed service in accordance with IEC 61089 / ASTM B232 / BS EN 50182.
Product
ACSR (Aluminum Conductor Steel Reinforced) Overhead Transmission Conductor (ACSR) engineered to IEC 61089 / ASTM B232 / BS EN 50182 for Up to 500 kV AC service across -40 °C to +80 °C, featuring galvanized high-tensile steel core and concentric 1350-h19
Typical values for this cable type, based on IEC 61089 / ASTM B232 / BS EN 50182 — confirmed in the datasheet and quotation for your order.
Application fit
ACSR (Aluminum Conductor Steel Reinforced) Overhead Transmission Conductor (ACSR) engineered to IEC 61089 / ASTM B232 / BS EN 50182 for Up to 500 kV AC service across -40 °C to +80 °C, featuring galvanized high-tensile steel core and concentric 1350-h19
Engineered and verified for fixed service in accordance with IEC 61089 / ASTM B232 / BS EN 50182.
Suitable for switchgear, control panels and equipment terminations within 20 × OD bend radius.
Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.
Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.
NSHTOU Reeling CableConstruction
Shown: ACSR (IEC 61089 / ASTM B232 / BS EN 50182) with galvanized high-tensile steel core, concentric 1350-h19 aluminum conductive layers and concentric 1350-h19 aluminum conductive layers (2-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Galvanized high-tensile steel core | Class A zinc-coated or aluminum-clad steel core strand (1, 7 or 19 wires)IEC 61089 / ASTM B232 / BS EN 50182 |
| 2 | Concentric 1350-H19 aluminum conductive layers | Hard-drawn 1350-H19 electrolytic aluminum wires stranded in reversed layersIEC 61089 / ASTM B232 / BS EN 50182 |
Built to IEC 61089 / ASTM B232 / BS EN 50182 with galvanized high-tensile steel core and concentric 1350-h19
Full range of metric mm² and AWG/kcmil conductor sizes per IEC 61089 / ASTM B232 / BS EN 50182
Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate
Technical data
Sizes
Manufactured to IEC 61089 / ASTM B232 / BS EN 50182 in standard cross-sections from 50 mm² to 630 mm² (and North American AWG/kcmil code words).
| Order designation | Nominal area | Stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Rated tensile kN ≈ | Min. sheave R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| ACSR Standard Transmission & Distribution Schedule (−40…+80 °C) | |||||||
| ACSR 50 mm² | 50 mm² | 7/3.00 mm | 9.0 | 138 | 14.5 | 180 | |
| ACSR 95 mm² | 95 mm² | 19/2.52 mm | 12.6 | 262 | 28.2 | 252 | |
| ACSR 120 mm² | 120 mm² | 19/2.85 mm | 14.3 | 334 | 36.4 | 286 | |
| ACSR 150 mm² | 150 mm² | 26/2.70 + 7/2.10 | 17.1 | 546 | 53.8 | 342 | |
| ACSR 185 mm² | 185 mm² | 26/3.00 + 7/2.33 | 19.0 | 674 | 65.2 | 380 | |
| ACSR 240 mm² | 240 mm² | 26/3.44 + 7/2.68 | 21.8 | 885 | 84.5 | 436 | |
| ACSR 300 mm² | 300 mm² | 26/3.86 + 7/3.00 | 24.5 | 1,110 | 104.2 | 490 | |
| ACSR 400 mm² | 400 mm² | 54/3.08 + 7/3.08 | 27.7 | 1,432 | 126.0 | 554 | |
| ACSR 500 mm² | 500 mm² | 54/3.44 + 7/3.44 | 31.0 | 1,790 | 156.5 | 620 | |
| ACSR 630 mm² | 630 mm² | 54/3.86 + 19/2.32 | 34.8 | 2,245 | 194.0 | 696 | |
| Nominal area | Max. DC R₂₀ Ω/km | Continuous current A ≈ | Operating temp. |
|---|---|---|---|
| 50 mm² | 0.578 | 210 | −40…+80 °C |
| 95 mm² | 0.304 | 320 | −40…+80 °C |
| 150 mm² | 0.192 | 435 | −40…+80 °C |
| 240 mm² | 0.119 | 590 | −40…+80 °C |
| 400 mm² | 0.072 | 820 | −40…+80 °C |
| 630 mm² | 0.046 | 1,080 | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (IEC 61089 / ASTM B232 / BS EN 50182) | DC resistance at 20 °C and geometry within IEC 61089 / ASTM B232 / BS EN 50182 class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (IEC 61089 / ASTM B232 / BS EN 50182) | Zero breakdown or structural defect over full production length | Every manufactured drum / spool |
| Sample tests | ||
| Thermal aging, mechanical & material qualification (IEC 61089 / ASTM B232 / BS EN 50182) | Full compliance with IEC 61089 / ASTM B232 / BS EN 50182 across −40…+80 °C | Type qualification & periodic sample audit |
Marking & supply
Sheath marking
Technical documents
FAQ