AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead ConductorIEC 61089 / ASTM B231 / BS EN 50182 · Up to 132 kV AC · -40 °C to +80 °C industrial AAC

AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor (AAC) engineered to IEC 61089 / ASTM B231 / BS EN 50182 for Up to 132 kV AC service across -40 °C to +80 °C, featuring central king wire & inner stranding and concentric outer aluminum stranding

Approved
Outdoor & humid
Ozone, UV & moisture
Order designation
AAC 240 mm²
Outer Ø ≈
21.8 mm
Total weight ≈
885 kg/km
Rated tensile ≈
84.5 kN
Stranding
26/3.44 + 7/2.68
All sizes (10)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Up to 132 kV AC
Per IEC 61089 / ASTM B231 / BS EN
Operating temp.
−40…+80 °C
Continuous thermal rating (IEC 61089)
Min. bend radius
20 × OD
Installed / fixed routing
Conductor
Central king
EC-grade 1350-H19 hard-drawn aluminum
Outer layer
Concentric
Helically stranded 1350-H19 aluminum
Standard
IEC 61089
IEC 61089 / ASTM B231 / BS EN 50182

Typical values for this cable type, based on IEC 61089 / ASTM B231 / BS EN 50182 — confirmed in the datasheet and quotation for your order.

Application fit

Is AAC right for your machine?

AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor (AAC) engineered to IEC 61089 / ASTM B231 / BS EN 50182 for Up to 132 kV AC service across -40 °C to +80 °C, featuring central king wire & inner stranding and concentric outer aluminum stranding

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with IEC 61089 / ASTM B231 / BS EN 50182.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 20 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesRenewable Energy & EV ChargingHigh-Voltage Grid & Substation InterconnectsWind, Solar & Hydro Power EvacuationUtility Overhead & Underground DistributionIndustrial Power Infrastructure

Construction

Layer by layer

Shown: AAC (IEC 61089 / ASTM B231 / BS EN 50182) with central king wire & inner stranding, concentric outer aluminum stranding layer and concentric outer aluminum stranding layer (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central king wire & inner strandingEC-grade 1350-H19 hard-drawn aluminum wires (≥ 61.0 % IACS)IEC 61089 / ASTM B231 / BS EN 50182
2Concentric outer aluminum stranding layerHelically stranded 1350-H19 aluminum outer layer with reversed lay directionIEC 61089 / ASTM B231 / BS EN 50182

AAC — Standard Execution

Built to IEC 61089 / ASTM B231 / BS EN 50182 with central king wire & inner stranding and concentric outer

AAC — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per IEC 61089 / ASTM B231 / BS EN 50182

AAC — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 61089 / ASTM B231 / BS EN 50182. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
Up to 132 kV AC (IEC 61089 / ASTM B231 / BS EN 50182)
Conductor construction
Central king wire & inner stranding — EC-grade 1350-H19 hard-drawn aluminum wires (≥ 61.0 % IACS)
Primary insulation / dielectric
Concentric outer aluminum stranding layer — Helically stranded 1350-H19 aluminum outer layer with reversed lay direction

Thermal

Continuous operating temperature
−40…+80 °C per IEC 61089 / ASTM B231 / BS EN 50182
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Concentric outer aluminum stranding layer — Helically stranded 1350-H19 aluminum outer layer with reversed lay direction
Minimum bending radius
20 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with IEC 61089 / ASTM B231 / BS EN 50182
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
IEC 61089 / ASTM B231 / BS EN 50182
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
AAC
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

10 standard AAC overhead conductor sizes

Manufactured to IEC 61089 / ASTM B231 / BS EN 50182 in standard cross-sections from 50 mm² to 630 mm² (and North American AWG/kcmil code words).

Dimensions, stranding, breaking load & weights
Order designationNominal areaStrandingOuter Ø ≈
mm
Weight ≈
kg/km
Rated tensile
kN ≈
Min. sheave R
mm
Enquiry
AAC Standard Transmission & Distribution Schedule (−40…+80 °C)
AAC 50 mm²50 mm²7/3.00 mm9.013814.5180
AAC 95 mm²95 mm²19/2.52 mm12.626228.2252
AAC 120 mm²120 mm²19/2.85 mm14.333436.4286
AAC 150 mm²150 mm²26/2.70 + 7/2.1017.154653.8342
AAC 185 mm²185 mm²26/3.00 + 7/2.3319.067465.2380
AAC 240 mm²240 mm²26/3.44 + 7/2.6821.888584.5436
AAC 300 mm²300 mm²26/3.86 + 7/3.0024.51,110104.2490
AAC 400 mm²400 mm²54/3.08 + 7/3.0827.71,432126.0554
AAC 500 mm²500 mm²54/3.44 + 7/3.4431.01,790156.5620
AAC 630 mm²630 mm²54/3.86 + 19/2.3234.82,245194.0696
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom kcmil/code-word sizes, grease-filled corrosion protection and non-specular surface finishes available per IEC 61089 / ASTM B231 / BS EN 50182.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (IEC 61089 / ASTM B231 / BS EN 50182)DC resistance at 20 °C and geometry within IEC 61089 / ASTM B231 / BS EN 50182 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (IEC 61089 / ASTM B231 / BS EN 50182)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (IEC 61089 / ASTM B231 / BS EN 50182)Full compliance with IEC 61089 / ASTM B231 / BS EN 50182 across −40…+80 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 61089 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX AAC <size> IEC 61089 Up to 132 kV AC CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define AAC (AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor)?
AAC (AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor) is manufactured in accordance with IEC 61089 / ASTM B231 / BS EN 50182 for Up to 132 kV AC service over -40 °C to +80 °C. Its 2-layer construction comprises central king wire & inner stranding, concentric outer aluminum stranding layer.
What is the minimum bending radius and installation temperature for AAC?
The minimum installed bending radius for AAC is 20 × OD across its continuous operating temperature range of -40 °C to +80 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of AAC arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central king wire & inner stranding (EC-grade 1350-H19 hard-drawn aluminum wires (≥ 61.0 % IACS)); (02) Concentric outer aluminum stranding layer (Helically stranded 1350-H19 aluminum outer layer with reversed lay direction).
What factory test certificates are supplied with AAC?
Every production drum or spool of AAC undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per IEC 61089 / ASTM B231 / BS EN 50182, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for AAC

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

AAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote