AS/NZS 3675 CCTAS/NZS 3675 / EN 50397-16.35/11 kV – 19/33 kV−25…+90 °C

CCT 6.35/11 kV XLPE Covered Overhead Distribution ConductorAS/NZS 3675 / EN 50397-1 · 6.35/11 kV – 19/33 kV · -25 °C to +90 °C industrial CCT

CCT 6.35/11 kV Covered Conductor Thick (XLPE) Overhead Distribution Line Cable (CCT) engineered to AS/NZS 3675 / EN 50397-1 for 6.35/11 kV – 19/33 kV service across -25 °C to +90 °C, featuring stranded aluminum conductor and xlpe covering core insulation with

Approved
Outdoor & humid
Ozone, UV & moisture
Order designation
CCT 240 mm²
Outer Ø ≈
21.8 mm
Total weight ≈
885 kg/km
Rated tensile ≈
84.5 kN
Stranding
26/3.44 + 7/2.68
All sizes (10)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6.35/11 kV
Per AS/NZS 3675 / EN 50397-1
Operating temp.
−25…+90 °C
Continuous thermal rating (AS)
Min. bend radius
15 × OD
Installed / fixed routing
Conductor
aluminum conduct
High-conductivity aluminum conductor
Outer layer
XLPE covering
Extruded XLPE covering dielectric
Standard
AS
AS/NZS 3675 / EN 50397-1

Typical values for this cable type, based on AS/NZS 3675 / EN 50397-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is CCT right for your machine?

CCT 6.35/11 kV Covered Conductor Thick (XLPE) Overhead Distribution Line Cable (CCT) engineered to AS/NZS 3675 / EN 50397-1 for 6.35/11 kV – 19/33 kV service across -25 °C to +90 °C, featuring stranded aluminum conductor and xlpe covering core insulation with

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with AS/NZS 3675 / EN 50397-1.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 15 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesRenewable Energy & EV ChargingHigh-Voltage Grid & Substation InterconnectsWind, Solar & Hydro Power EvacuationUtility Overhead & Underground DistributionIndustrial Power Infrastructure

Construction

Layer by layer

Shown: CCT (AS/NZS 3675 / EN 50397-1) with stranded aluminum conductor, xlpe covering core insulation and xlpe covering core insulation (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded aluminum conductorHigh-conductivity aluminum conductor per AS/NZS 3675 / EN 50397-1AS/NZS 3675 / EN 50397-1
2XLPE covering core insulationExtruded XLPE covering dielectric (continuous layer)AS/NZS 3675 / EN 50397-1

CCT — Standard Execution

Built to AS/NZS 3675 / EN 50397-1 with stranded aluminum conductor and xlpe covering core insulation

CCT — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per AS/NZS 3675 / EN 50397-1

CCT — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on AS/NZS 3675 / EN 50397-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
6.35/11 kV – 19/33 kV (AS/NZS 3675 / EN 50397-1)
Conductor construction
Stranded aluminum conductor — High-conductivity aluminum conductor per AS/NZS 3675 / EN 50397-1
Primary insulation / dielectric
XLPE covering core insulation — Extruded XLPE covering dielectric (continuous layer)

Thermal

Continuous operating temperature
−25…+90 °C per AS/NZS 3675 / EN 50397-1
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
XLPE covering core insulation — Extruded XLPE covering dielectric (continuous layer)
Minimum bending radius
15 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with AS/NZS 3675 / EN 50397-1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
AS/NZS 3675 / EN 50397-1
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CCT
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

10 standard CCT overhead conductor sizes

Manufactured to AS/NZS 3675 / EN 50397-1 in standard cross-sections from 50 mm² to 630 mm² (and North American AWG/kcmil code words).

Dimensions, stranding, breaking load & weights
Order designationNominal areaStrandingOuter Ø ≈
mm
Weight ≈
kg/km
Rated tensile
kN ≈
Min. sheave R
mm
Enquiry
CCT Standard Transmission & Distribution Schedule (−25…+90 °C)
CCT 50 mm²50 mm²7/3.00 mm9.013814.5180
CCT 95 mm²95 mm²19/2.52 mm12.626228.2252
CCT 120 mm²120 mm²19/2.85 mm14.333436.4286
CCT 150 mm²150 mm²26/2.70 + 7/2.1017.154653.8342
CCT 185 mm²185 mm²26/3.00 + 7/2.3319.067465.2380
CCT 240 mm²240 mm²26/3.44 + 7/2.6821.888584.5436
CCT 300 mm²300 mm²26/3.86 + 7/3.0024.51,110104.2490
CCT 400 mm²400 mm²54/3.08 + 7/3.0827.71,432126.0554
CCT 500 mm²500 mm²54/3.44 + 7/3.4431.01,790156.5620
CCT 630 mm²630 mm²54/3.86 + 19/2.3234.82,245194.0696
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom kcmil/code-word sizes, grease-filled corrosion protection and non-specular surface finishes available per AS/NZS 3675 / EN 50397-1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (AS/NZS 3675 / EN 50397-1)DC resistance at 20 °C and geometry within AS/NZS 3675 / EN 50397-1 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (AS/NZS 3675 / EN 50397-1)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (AS/NZS 3675 / EN 50397-1)Full compliance with AS/NZS 3675 / EN 50397-1 across −25…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

AS CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CCT <size> AS 6.35/11 kV – 19/33 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define CCT (CCT 6.35/11 kV Covered Conductor Thick (XLPE) Overhead Distribution Line Cable)?
CCT (CCT 6.35/11 kV Covered Conductor Thick (XLPE) Overhead Distribution Line Cable) is manufactured in accordance with AS/NZS 3675 / EN 50397-1 for 6.35/11 kV – 19/33 kV service over -25 °C to +90 °C. Its 2-layer construction comprises stranded aluminum conductor, xlpe covering core insulation.
What is the minimum bending radius and installation temperature for CCT?
The minimum installed bending radius for CCT is 15 × OD across its continuous operating temperature range of -25 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of CCT arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded aluminum conductor (High-conductivity aluminum conductor per AS/NZS 3675 / EN 50397-1); (02) XLPE covering core insulation (Extruded XLPE covering dielectric (continuous layer)).
What factory test certificates are supplied with CCT?
Every production drum or spool of CCT undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per AS/NZS 3675 / EN 50397-1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CCT

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CCT 6.35/11 kV XLPE Covered Overhead Distribution Conductor

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote