What the video shows
Factory footage and engineering diagrams introduce the 0.6/1 kV 2PNCT-BS 6P×2.0 mm² control reeling cable for dam gantry and vertical hoist applications.
The video illustrates a sample, process, or operating context. Final product construction, suitability, standards, and test acceptance criteria are confirmed against the ordered specification.
TL;DR: This 91.5 second (1:32) video inspects our TEBAOFLEX® 0.6/1kV 2PNCT-BS · 6Px2.0 mm² (12 Cores) pair-shielded control reeling cable built to JIS C 3327 (2026) and JCS 4396 (2026). It pairs live cooling sheaves, twin-belt haul-off, drum spooling, 4K QC, and six workshop photos (0:00 to 0:03, 0:10 to 0:19, 0:51 to 1:02, and 1:15 to 1:25) with 3D dam gantry hoist kinematics. Inside the ~31.0 mm (1.22 in) 2nd Kind CR jacket, six Black x White 90 °C EPR twisted pairs (37/0.26 mm Class 5 copper, max. 10.2 Ω/km) each carry an independent min. 85% bare copper braid per JCS 4396 (2026). A central rubber-coated steel wire rope carries vertical drop loads for strain-free min. 6 x OD (~186 mm) reeling.
On hydroelectric dam crest gantry cranes, deep intake gate lifting beams, and port spreaders, vertical control reeling cables face two constant hazards. First, deep vertical drops into concrete gate shafts pull hard on slender 2.0 mm² copper signal wires and snap unreinforced cores. Second, nearby high-power VFD hoist motors send electromagnetic interference (EMI) into 4 to 20 mA depth encoders, load pins, and 24V DC lock-pin solenoids. This video page pairs our 91.5 second factory production and 4K QC check of the 0.6/1kV 2PNCT-BS 6Px2.0mm² Control Reeling Cable with 24V DC loop drop tables. You also get a buyer QA checklist.
What Does the 92 Second 0.6/1kV 2PNCT-BS 6Px2.0mm² Video Show?
The 91.5 second (1:32) video is split into eight clear chapters so hydro engineers and crane OEMs can check both vertical gate-slot reeling geometry and real factory specimens. The table below separates uncropped 16:9 live line footage, 4K QC video, and 4000x3000 workshop photos from 3D mechanical schematics.
| Timestamp | Video Chapter | Visual Format | Key Engineering Evidence Verified On-Screen |
|---|---|---|---|
| 0:00 - 0:03 | Opening Specimen & Dam Gantry Card | Real Rosette Cut + Dam Scene | Real 6Px2.0mm² (6xCu Braid + Steel Core) macro cut and "0.6/1kV 2PNCT-BS Cable 6PX2.0mm² Apr 2026" print beside a dam crest gantry hoist. |
| 0:03 - 0:10 | 01 · 6-Pair + Steel Core Reveal | 2D & 3D CAD Geometry | Symmetrical Ø ~31.0 mm 6-pair rosette (Black x White EPR + copper braids) around a central steel wire tension core. |
| 0:10 - 0:19 | 01B · Live Sheaves, Haul-Off & Reel | Uncropped 16:9 Live Factory Video | 01A (0:10): Multi-groove cooling sheaves. 01B (0:13): Twin-belt caterpillar haul-off. 01C (0:16): Layer-wound wooden drum spooling. |
| 0:19 - 0:32 | 02 · Dam Crest Gantry Hoist Scene | 3D Kinematic & X-Ray Schematic | 3 point vertical path ([1] Motorized Control Reel to [2] 4 Roller Guide to [3] Lifting Beam Sensor Box) over a 6.7 m demo drop. |
| 0:32 - 0:51 | 03 · 5-Layer Pair-Shielded Cutaway | 3D Stepped Layer Strip-Back | Sequential strip-back from Layer 05 (integral CR sheath) and Layer 04 (6xCu braids) down to Layer 02 (steel core) and Layer 01 (12 cores). |
| 0:51 - 1:02 | 03B · Live 4K QC Video & Macros | Uncropped 4K 16:9 QC Video | 02A (0:54): Flush-cut 6Px2.0mm² + steel core check. 02B (0:57): "0.6/1kV 2PNCT-BS Cable 6PX2.0mm² Apr 2026" scan. 02C (1:01): QC tag (2026.4.15). |
| 1:02 - 1:15 | 04 & 05 · Overview & 6 Card Specs | 2D/3D Callout + Spec Matrix | Full 5-layer table plus 6 card matrix (0.6/1 kV, ~31.0 mm OD, 6 x Cu min. 85% Braid, 90 °C EPR, 37/0.26 mm, min. 6 x OD). |
| 1:15 - 1:31.5 | 06 · 6 Sample Photos & Contact Card | 6 Uncropped 4000x3000 Photos | Board 01 (Photos 01 to 03) and Board 02 (Photos 04 to 06) verifying center steel rope, copper braids, and AC 3000V/1min legend. |

A JIS C 3327 / JCS 4396 2PNCT-BS control reeling cable is a heavy-duty rubber cabtyre cable combining 90 °C EPR twisted pairs, individual copper braids (S), a steel tension core, and a CR sheath. In Japanese cable codes (JCS 4396), -B marks dynamic drum reeling reinforcement and S marks electrostatic and electromagnetic pair shielding.
Technical Specification Summary (0.6/1kV 2PNCT-BS · 6Px2.0mm²)
We compiled the verified readings from our live extrusion line (0:10 to 0:19), 4K QC bench check (0:51 to 1:02), and spec cards (1:11 to 1:15) alongside the governing Japanese and IEC standards.
| Parameter | Verified Video & Specimen Value | Governing Standard / Benchmark | Practical Dam & Hoist Field Meaning |
|---|---|---|---|
| Model Designation | 0.6/1kV 2PNCT-BS · 6Px2.0mm² | JIS C 3327 / JCS 4396 | Heavy-duty pair-shielded 6-pair (12-core) vertical reeling control cable. |
| Rated Voltage & Test | 0.6/1 kV (AC 3,000 V / 1 min test) | JIS C 3005 / IEC 60502-1 | High dielectric margin for mixed 24V DC, 110V, and 220V AC control circuits. |
| Signal Conductors (Layer 01) | 6 Pairs x 2.0 mm² (12 Cores, 37/0.26 mm) | IEC 60228 Class 5 / JIS C 3102 Bare Copper | Low loop resistance (R20 max. 10.2 Ω/km per core) for long vertical gate drops. |
| Central Tension Core (Layer 02) | Rubber-Coated Galvanized Steel Wire Rope | Multi-strand steel rope on neutral center axis | Carries vertical hanging weight and reel pull so 2.0 mm² copper pairs stay strain-free. |
| Twisted-Pair Dielectric (Layer 03) | 90 °C Cross-Linked EPR (Black x White) | JIS C 3327 (1 Black + 1 White per pair) | -25 °C to +90 °C thermal rating with clear polarity inside every pair. |
| Pair EMI Shields (Layer 04) | 6 x Individual Bare Copper Wire Braids | EN 50289-1-6 / JCS 4396 (min. 85% density) | Isolates VFD hoist motor harmonics and stops inter-pair signal crosstalk. |
| Integral Outer Sheath (Layer 05) | Matte Black 2nd Kind Polychloroprene (CR) | JIS C 3327 / ISO 4649 abrasion | Gusset-extruded into 6-pair valleys; resists dam mist, hydraulic oil (IEC 60811-404), and UV. |
| Nominal Outer Diameter (OD) | Approx. Ø 31.0 mm (1.22 in) | Twin-belt caterpillar haul-off roundness QC | Balanced circular profile (1.45 to 1.62 kg/m approx. weight) for 4 roller guides. |
| Min. Dynamic Bend Radius | Min. 6 x OD (~186 mm / 7.32 in) | Vertical hoist-coupled motorized reel duty | Compact drum barrel sizing on dam crest gantry platforms. |
Engineering Boundary Note (Live Footage vs. 3D Schematics): Chapters 01B (0:10 to 0:19), 03B (0:51 to 1:02), and 06 (1:15 to 1:25) show uncropped live TEBAOFLEX production footage, 4K specimen scans, and 4000x3000 workshop photos of the "0.6/1kV 2PNCT-BS Cable 6PX2.0mm² Apr 2026" batch. Chapters 01 through 05 use 3D CAD schematics to illustrate internal layers and dam gate hoist motion. Card 04 (1:12) sets a conservative -25 °C to +90 °C flexing range to protect the six copper braid shields during sub-zero vertical reeling on alpine dam crests.
How Do the Central Steel Core and 6 Copper Braids Protect Gate Signals?
Standard multi-core control cables without a center steel rope stretch when hung down a 30 m to 100 m dam intake shaft. Once soft 2.0 mm² copper wires yield by even 1% to 2% under IEC 60228 (2026), twisted pairs untwist, shields open up, and 4 to 20 mA gate-level feedback drifts. As shown in Chapter 03 (0:32 to 0:51) and verified in the 0:54 4K macro cut, our 0.6/1kV 2PNCT-BS 6Px2.0mm² separates mechanical pull from signal cores across five layers.

A central rubber-coated steel wire rope tension core is a multi-strand galvanized steel wire rope cushioned in an extruded elastomer sleeve along the exact neutral axis (Layer 02) of a vertical reeling cable. Anchoring this center steel core at the drum hub and lifting-beam grip lets the steel rope carry 100% of the vertical drop load per JCS 4396 (2026) without chafing the EPR pairs.

Working from the copper conductors outward (Layer 01 to Layer 05), each layer stops a specific vertical hoist failure mode.
- Layer 01: 6P x 2.0 mm² (12 Cores, 37/0.26 mm) Class 5 Bare Copper Conductors (0:47 to 0:51). Each of the 12 signal cores uses 37 fine 0.26 mm annealed bare copper strands (2.0 mm² nominal JIS size), keeping 20 °C DC resistance at max. 10.2 Ω/km. Pairing 1 Black + 1 White core with a short balanced twist pitch rejects common-mode magnetic hum.
- Layer 02: Central Rubber-Coated Galvanized Steel Wire Rope (0:44 to 0:47). Visible dead-center in the 0:54 4K macro end-face (a galvanized steel wire bundle inside a black rubber cushion), this high-modulus core stops axial stretch on 1:1 hoist-coupled drops. It still bends smoothly down to 6 x OD (186 mm).
- Layer 03: 90 °C Cross-Linked EPR Twisted-Pair Insulation (Black x White) (0:40 to 0:44). Unlike PVC insulation that stiffens in cold mountain air or softens near hot brake resistors, cross-linked EPR keeps stable low capacitance. Every core passes a 3,000 V / 1 min AC withstand test across -25 °C to +90 °C.
- Layer 04: 6 x Individual Bare Copper Wire Braid Pair Shields (Min. 85% Density) (0:36 to 0:40). Rather than wrapping one overall shield around all 12 wires, we enclose every Black x White twisted pair inside its own min. 85% woven bare copper braid per JCS 4396 (2026). For example, you can run 24V DC solenoid pulses, 4 to 20 mA load cells, and RS-485 depth encoders in one cable with zero crosstalk.
- Layer 05: Heavy-Duty Gusset-Extruded 2nd Kind Polychloroprene (CR) Sheath (0:32 to 0:36). Extruded deep into the six outer valleys of the braided pair rosette (Ø ~31.0 mm), the matte black CR jacket locks roundness across four-roller vertical guides. It also resists reservoir mist, turbine oil, and UV ozone.
For background on how center support cores perform in vertical crane drops, read our guide on Crane Spreader Cable Basket vs. Vertical Reel Design.
How Does 3 Point Vertical Gate-Slot Reeling & Shield Earthing Work?
In Chapter 02 (0:19 to 0:32), the video shows a Hydroelectric Dam Crest Gantry Hoist Crane lowering an automatic hydraulic lifting beam into a deep concrete intake gate slot (6.7 m demo span, scalable to 100 m shafts).

- Point [1]: Motorized Control Cable Reel (0:22 to 0:25). Mounted on the upper gantry deck beside the stainless PLC cabinet, a torque-regulated control drum winds the 2PNCT-BS 6Px2.0mm² cable in 1:1 sync with the main wire-rope hoist. Twelve low-noise instrumentation slip-ring channels route the 6 shielded pairs into the PLC rack.
- Point [2]: Yellow 4 Roller Guide Fairlead (0:22 to 0:32). A cantilevered four-roller guide frame centers the Ø 31.0 mm cable right over the vertical gate slot axis (min. 6 x OD = 186 mm roller arc). That stops concrete slot scraping under cross-canyon winds.
- Point [3]: Waterproof Lifting Beam Sensor Box (0:22 to 0:28). At the submerged grappling beam, a stainless mesh grip and IP68 gland transfer vertical weight onto the central steel wire rope (Layer 02). Inside the box, the 6 braided pairs monitor left and right latch-pin sensors, slack-rope switches, and gate-tilt transducers.
Shield Grounding Tip: For analog 4 to 20 mA sensors on dam lifting beams, ground each pair's copper braid at the gantry PLC cabinet end only to block earth-potential ground loops. For high-frequency RS-485 or encoder pairs, apply 360° EMC bonding as explained in our guide on Shielded Control Cable 1 End vs. 2 End Grounding.
How Far Can 6Px2.0mm² Pairs Drive 24V DC Solenoids and 4-20 mA Sensors?
Video Chapter 05 (1:12) verifies a 20 °C conductor DC resistance of max. 10.2 Ω/km (37/0.26 mm Class 5 copper, 2.0 mm² per core). Because dam intake shafts and mine hoists often drop 30 m to 120 m vertically, engineers must check round-trip loop resistance (R_loop = 2 × L × R_T) and 24V DC voltage drop. Submerged latch-pin solenoids need coil voltage drop kept within 10% (max. 2.4 V on 24V DC) per IEC 60364-5-52 (2026) to pull in reliably.
Vertical Shaft Signal Loop Resistance, 24V DC Drop & Tension Table (6Px2.0mm²)
| Total Cable Length (L, Reel + Drop) | Round-Trip Loop Resistance at 20°C (20.4 Ω/km) | Round-Trip Loop Resistance at 60°C (23.6 Ω/km) | 24V DC Drop at 0.5 A Proximity / PLC Load | 24V DC Drop at 1.5 A Hydraulic Lock-Pin Valve | 4-20 mA Loop Drop at 20 mA (max. 500 Ω budget) | Approx. Suspended Cable Weight (~1.55 kg/m) |
|---|---|---|---|---|---|---|
| 25 m | 0.51 Ω | 0.59 Ω | 0.30 V (1.25% of 24V). | 0.89 V (3.71% of 24V). | 0.012 V (negligible). | ~39 kg (~380 N on steel core). |
| 50 m | 1.02 Ω | 1.18 Ω | 0.59 V (2.46% of 24V). | 1.77 V (7.38% of 24V). | 0.024 V (negligible). | ~78 kg (~765 N on steel core). |
| 80 m | 1.63 Ω | 1.89 Ω | 0.95 V (3.96% of 24V). | 2.84 V (11.8%, parallel 2 pairs). | 0.038 V (negligible). | ~124 kg (~1,215 N on steel core). |
| 120 m | 2.45 Ω | 2.83 Ω | 1.42 V (5.92% of 24V). | 4.25 V (17.7%, use 110V coil). | 0.057 V (negligible). | ~186 kg (~1,825 N on steel core). |
Check coil pull-in margins on deep shafts. Individual pair copper wire braid shielding (min. 85% coverage) per EN 50289-1-6 (2026) is a dedicated tubular weave of fine bare copper wires wrapped around each Black x White EPR twisted pair (Layer 04). It provides 55 dB to 70 dB of crosstalk attenuation between 110V AC commands and milliamp sensor loops.
We calculated this methodology from R20 = 10.2 Ω/km (R60 = 11.8 Ω/km per core, or 23.6 Ω/km round-trip pair loop). Its multi-pair thermal limit is 14 A per 2.0 mm² pair (6 loaded pairs at 30 °C per JCS 0168 (2026)). For example, at 80 m, 4 to 20 mA sensors and 0.5 A PLC inputs drop under 1.0 V. By contrast, a 1.5 A 24V DC lock-pin valve drops 2.84 V (11.8%), so shafts deeper than 65 m should parallel two pairs or use 110V AC coils.
How Does 2PNCT-BS Compare with 2PNCT-B, 3GSLTÖ, and Rondoflex (C)?
When picking dynamic reeling cables for dams, shipyards, and container ports, engineers choose between pair-shielded steel-core control cables (2PNCT-BS), main power reeling cables (2PNCT-B), and European VDE screened control cables. Use the matrix below to match the right model to your crane duty.
| Cable Series & Standard | Core Geometry | Axial Tension Element | EMI Shielding | Min. Reeling Bend Radius | Best-Fit Dynamic Application |
|---|---|---|---|---|---|
| 0.6/1kV 2PNCT-BS 6Px2.0mm² (This Video: JIS C 3327 / JCS 4396) | 6 Twisted Pairs (12 x 2.0 mm², Bk x W) | Central Rubber-Coated Steel Wire Rope | 6 x Individual Pair Cu Braids (min. 85%) | 6 x OD (~186 mm at Ø 31.0 mm) | Hydroelectric dam intake gate vertical reels, deep shaft sensors, and VFD hoist control. |
| 0.6/1kV 2PNCT-B 3x60mm² (JIS C 3327 / JCS 4396) | 3 x 60 mm² Trefoil Power (Bk / W / R) | Center Synthetic Tensile Cord + Gusset Lock | Unshielded Power | 8 x OD (~308 mm at Ø 38.5 mm) | Shipyard dry-dock portal jib crane and bulk loader 100 to 160 kW main travel drums. |
| 600V Flat 2PNCT 3x38mm²+E (JIS C 3327) | 4 x 38 mm² Coplanar Flat (G/R/W/Bk) | Integral 4 Hole Molded CR Web | Unshielded Power | 6 x H (~116 mm minor axis) | Coastal STS port crane box-girder overhead I-beam festoon trolley loops. |
| 3GSLTÖ Screened Spreader (VDE 0250 Special) | 18 to 48 Control Cores + Shielded Pairs | Central Aramid (Kevlar®) Support Core | Overall or Group Tinned Cu Braid | 7.5 x OD to 10 x OD | High-speed STS / RTG gravity-fed container spreader baskets (up to 240 m/min). |
| (N)GRDGCGOEU / Rondoflex (C) (DIN VDE 0250-814) | 12 to 36 Multi-Core (1.5 or 2.5 mm²) | Center Elastomer Cushion + Outer Braid | Overall Tinned Copper Braid ((C)) | 7.5 x OD to 10 x OD | Horizontal crane trolley festoons and level-wind drums without deep vertical hang weight. |
For complete drum torque and multi-layer derating steps across horizontal and vertical reels, read our 7-Step Crane Reeling Cable Selection Guide.
What Do the Live Factory Line, 4K Macro QC, and 6 Sample Photos Verify?
Chapters 01B (0:10 to 0:19), 03B (0:51 to 1:02), and 06 (1:15 to 1:25) show our manufactured batch of TEBAOFLEX® 0.6/1kV 2PNCT-BS 6Px2.0mm² across three live production clips, three 4K QC scans, and six 4000x3000 photos. Your site QA inspector can check five physical details directly against these frames.


Buyer Receiving & Pre-Shipment FAT Inspection Checklist
- Verify the Permanent Dot-Matrix Sheath Legend (0:01, 0:57, and 1:21). Inspect the matte black 2nd Kind CR outer jacket (Ø ~31.0 mm). Confirm crisp white dot-matrix marking reading "0.6/1kV 2PNCT-BS Cable 6PX2.0mm² Apr 2026" (4K QC Video 02B and Specimen Photo 06).
- Audit the Signed Physical Factory QC Sample Tag (0:59 to 1:02). Match each wooden shipping drum and witness cut against the signed QC tag filmed in 4K QC Video 02C (1:01). It records Brand: TEBAOFLEX CABLE, Voltage: 0.6/1kV, Type: 2PNCT-BS, Size: 6Px2.0, and Date: 2026.4.15.
- Inspect the Central Galvanized Steel Rope & 6-Pair Rosette End-Face (0:54 & 1:16). Make a flush perpendicular cut and compare it with 4K QC Video 02A (0:54) and Specimen Photo 01 (1:16). Verify the multi-strand galvanized steel wire tension rope cushioned in rubber at the center, surrounded symmetrically by six Black x White 90 °C EPR twisted pairs.
- Check Min. 85% Individual Bare Copper Pair Braid Coverage (0:38, 0:54, and 1:16). Strip 40 mm of outer CR jacket and check that each Black x White pair sits inside its own dense bare copper wire braid (min. 85% coverage per JCS 4396 (2026)) with solid gusset rubber filling the outer valleys.
- Confirm Layer-Wound Drum Spooling (0:16) & AC 3,000V / 1 min FAT Reports (1:21). As shown in Live Video 01C (0:16), finished reels are layer-wound without twist memory. Check the batch FAT report (Specimen Photo 06 note) confirming 100% factory AC 3,000 V / 1 min dielectric testing per JIS C 3005 (2026). Also verify 20 °C conductor DC resistance (max. 10.2 Ω/km) and shield continuity.


Frequently Asked Questions About 0.6/1kV 2PNCT-BS 6Px2.0mm² Cables
What does 2PNCT-BS mean under Japanese standards JIS C 3327 and JCS 4396?
In Japanese cable designations (JIS C 3327 and JCS 4396), 2PNCT marks a 90 °C EPR-insulated, 2nd kind heavy polychloroprene (CR) sheathed cabtyre cable. The -B suffix indicates dynamic reeling reinforcement (here using a central rubber-coated steel wire tension rope), while S denotes electrostatic and electromagnetic shielding (6 individual min. 85% bare copper braids).
Why use 6 individually braided pairs (6Px2.0mm²) instead of one overall shield on a dam gantry crane?
A single overall shield blocks external VFD motor noise, but it cannot stop internal crosstalk between wires inside the same cable. Wrapping each Black x White 2.0 mm² pair in its own min. 85% bare copper braid per JCS 4396 (2026) isolates 24V DC / 110V AC valve switching spikes from 4 to 20 mA load-cell and gate-depth signals.
How must the central galvanized steel wire tension core be terminated at the lifting beam?
Never crimp the central steel wire rope into an electrical terminal block, and never let the 12 copper 2.0 mm² signal cores carry vertical suspension pull. Anchor the cable jacket externally using a stainless wire-mesh basket grip at the lifting-beam entry gland, and clamp the central steel tension rope to the strain-relief bracket inside the junction box.
Why is 2.0 mm² (37/0.26 mm) specified instead of 0.75 mm² or 1.25 mm² for vertical gate reels?
Hydroelectric intake gate shafts and deep crane hoists often require 50 m to 120 m total cable runs (reel + vertical drop). Using 2.0 mm² (37/0.26 mm, R20 max. 10.2 Ω/km) cuts round-trip loop resistance by 62% compared with 0.75 mm² (26.7 Ω/km) per IEC 60228 (2026), stopping 24V DC solenoid under-voltage dropouts.
Which segments of the 91.5 second video show live production and real physical samples?
Authentic factory production and physical specimens appear in four verified blocks. First, the opening card (0:00 to 0:03) shows the real cut specimen. Second, Chapter 01B (0:10 to 0:19) shows live multi-groove cooling sheaves, twin-belt caterpillar haul-off, and wooden reel spooling. Third, Chapter 03B (0:51 to 1:02) shows 4K QC video of the flush-cut 6-pair + steel core rosette, "0.6/1kV 2PNCT-BS Cable 6PX2.0mm² Apr 2026" sheath legend, and 2026.4.15 signed QC tag. Fourth, Chapter 06 (1:15 to 1:25) displays six uncropped 4000x3000 sample photos.
Request a Quote or Sample for JIS C 3327 / JCS 4396 2PNCT-BS Control Cables
Whether you are upgrading vertical intake-gate reels on hydroelectric dam gantry cranes or buying custom pair-shielded 2PNCT-BS / 3PNCT reeling cables (2P to 24P, 1.25 mm² to 3.5 mm²), our team can help. We supply cut sample specimens, datasheets, and AC 3,000 V FAT reports. Explore our Crane Reeling Cable Portfolio or contact TEBAOFLEX engineering for a fast quote.
WhatsApp: +86 185 9591 3361.











