Fixed installation
Traction converter cubicles, driver desk harnesses, auxiliary battery feeders and car-body conduits.
Product
Space- and weight-saving reduced-wall single-core railway rolling-stock power and control wire certified to EN 50264-3-1 (`0.6/1 kV` and `1.8/3 kV`, code `M`) with Class 5 tinned copper conductors (0.5–240 mm²) and e-beam cross-linked EI 109 LSZH insulation.
Typical values for this cable type, based on EN 50264-3-1 / EN 45545-2 HL1–HL3 — confirmed in the datasheet and quotation for your order.
Application fit
EN 50264-3-1 replaces thick elastomeric walls (`EN 50264-2-1`) with high-modulus electron-beam cross-linked `EI 109` co-extruded insulation, cutting cable diameter by up to 30 % and weight by up to 25 % in railway switchgear cabinets, traction cubicles and under-frame ducts.
Traction converter cubicles, driver desk harnesses, auxiliary battery feeders and car-body conduits.
1.8/3 kV class is widely used inside shielded traction inverter cubicles; use screened cable for external runs.
Use EN 50264-3-2 MMSSingle-core protected rolling-stock wire; for multi-core external bogie cables, select EN 50264-2-2.
Use EN 50264-2-2For 300 V ultra-thin-wall cabinet and rack wiring (0.5–2.5 mm²), select EN 50306-2.
Use EN 50306-2Construction
Shown: EN 50264-3-1 600 V 1×2.5 M — Class 5 tinned annealed copper conductor and co-extruded reduced-wall electron-beam cross-linked halogen-free polymer insulation (inner dielectric core + outer oil/fuel-resistant EI 109 skin).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 5 tinned copper conductor | Fine-stranded tinned annealed copper to EN 60228 Class 5 (0.5 to 240 mm²)EN 60228 Class 5 · EN 50264-3-1 |
| 2 | Inner cross-linked dielectric layer | Electron-beam cross-linked halogen-free polyolefin/copolymer primary dielectric layerEN 50264-1 EI 109 |
| 3 | Outer EI 109 / EM 104 skin | Co-extruded reduced-wall electron-beam cross-linked outer insulation/sheath resistant to oil, fuel and −40 °C coldEN 50264-3-1 · EN 45545-2 HL3 |
Reduced-wall single-core control and auxiliary power wire (max. 720/1200 V AC, 900/1800 V DC)
Reduced-wall medium-voltage traction and DC link feeder cable (max. 2.2/3.6 kV AC, 2.7/5.4 kV DC)
Technical data
Sizes
Typical EN 50264-3-1 / EN 45545-2 HL1–HL3 outer diameter limits, copper content and cable weight.
| Order designation | Cores × mm² / AWG | AWG ≈ | Outer Ø min mm | Outer Ø max mm | Copper kg/km | Weight ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|---|
| 0.6/1 kV (600 V) Reduced-Wall Control & Panel Wires (0.5–6 mm²) | ||||||||
| EN 50264-3-1 600V 1×0.5 M | 1×0.5 | 20 | 1.9 | 2.1 | 4 | 9 | 6 | |
| EN 50264-3-1 600V 1×0.75 M | 1×0.75 | 18 | 2.1 | 2.3 | 7 | 12 | 7 | |
| EN 50264-3-1 600V 1×1.0 M | 1×1.0 | 18 | 2.3 | 2.5 | 9 | 15 | 8 | |
| EN 50264-3-1 600V 1×1.5 M | 1×1.5 | 16 | 2.6 | 2.8 | 14 | 20 | 8 | |
| EN 50264-3-1 600V 1×2.5 M | 1×2.5 | 14 | 3.0 | 3.3 | 24 | 31 | 10 | |
| EN 50264-3-1 600V 1×4 M | 1×4 | 12 | 3.7 | 4.0 | 38 | 47 | 12 | |
| EN 50264-3-1 600V 1×6 M | 1×6 | 10 | 4.2 | 4.6 | 57 | 68 | 14 | |
| 0.6/1 kV (600 V) Reduced-Wall Auxiliary Power Leads (10–240 mm²) | ||||||||
| EN 50264-3-1 600V 1×10 M | 1×10 | 8 | 5.4 | 5.9 | 96 | 114 | 18 | |
| EN 50264-3-1 600V 1×16 M | 1×16 | 6 | 6.4 | 7.0 | 153 | 174 | 21 | |
| EN 50264-3-1 600V 1×25 M | 1×25 | 4 | 8.0 | 8.7 | 240 | 268 | 26 | |
| EN 50264-3-1 600V 1×35 M | 1×35 | 2 | 9.3 | 10.1 | 336 | 368 | 30 | |
| EN 50264-3-1 600V 1×50 M | 1×50 | 1/0 | 10.9 | 11.9 | 480 | 520 | 36 | |
| EN 50264-3-1 600V 1×70 M | 1×70 | 2/0 | 12.7 | 13.8 | 672 | 718 | 41 | |
| EN 50264-3-1 600V 1×95 M | 1×95 | 3/0 | 14.4 | 15.6 | 912 | 955 | 47 | |
| EN 50264-3-1 600V 1×120 M | 1×120 | 4/0 | 16.1 | 17.5 | 1,152 | 1,205 | 52 | |
| EN 50264-3-1 600V 1×150 M | 1×150 | 300 kcmil | 18.0 | 19.6 | 1,440 | 1,500 | 59 | |
| EN 50264-3-1 600V 1×185 M | 1×185 | 350 kcmil | 20.1 | 21.8 | 1,776 | 1,845 | 65 | |
| EN 50264-3-1 600V 1×240 M | 1×240 | 500 kcmil | 22.6 | 24.6 | 2,304 | 2,390 | 74 | |
| 1.8/3 kV (1800 V) Reduced-Wall Traction & DC Link Feeders | ||||||||
| EN 50264-3-1 1800V 1×2.5 M | 1×2.5 | 14 | 4.7 | 5.1 | 24 | 49 | 15 | |
| EN 50264-3-1 1800V 1×10 M | 1×10 | 8 | 7.0 | 7.6 | 96 | 142 | 23 | |
| EN 50264-3-1 1800V 1×35 M | 1×35 | 2 | 10.9 | 11.8 | 336 | 412 | 35 | |
| EN 50264-3-1 1800V 1×95 M | 1×95 | 3/0 | 16.1 | 17.5 | 912 | 1,025 | 52 | |
| Cross-section mm² | AWG ≈ | Max. DC resistance 20 °C, Ω/km | Single wire in air 30 °C, A | Multi-core bundle 30 °C, A |
|---|---|---|---|---|
| 0.5 | 20 | 40.1 | 10 | 7 |
| 0.75 | 18 | 26.7 | 13 | 10 |
| 1 | 18 | 20 | 16 | 12 |
| 1.5 | 16 | 13.7 | 21 | 16 |
| 2.5 | 14 | 8.21 | 30 | 22 |
| 4 | 12 | 5.09 | 41 | 30 |
| 6 | 10 | 3.39 | 53 | 38 |
| 10 | 8 | 1.95 | 75 | 53 |
| 16 | 6 | 1.24 | 100 | 71 |
| 25 | 4 | 0.795 | 135 | 94 |
| 35 | 2 | 0.565 | 169 | 117 |
| 50 | 1/0 | 0.393 | 215 | 148 |
| 70 | 2/0 | 0.277 | 270 | 185 |
| 95 | 3/0 | 0.21 | 330 | 225 |
| 120 | 4/0 | 0.164 | 385 | 260 |
| 150 | 300 kcmil | 0.132 | 445 | 300 |
| 185 | 350 kcmil | 0.108 | 510 | 340 |
| 240 | 500 kcmil | 0.082 | 605 | 400 |
Reel check
A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC dielectric voltage test | 3.5 kV AC (50/60 Hz) | Every manufactured length |
| Conductor DC resistance | IEC 60228 / ASTM (tinned copper) | Every manufactured length |
| Sample tests | ||
| Flame propagation test | IEC 60332-1-2 / UL VW-1 / ISO 6722-1 | Per production batch |
| Insulation & sheath material physical properties | EN 50264-3-1 / EN 45545-2 HL1–HL3 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.