Hook-up & equipment wiresEN 50264-3-10.6/1 kV & 1.8/3 kVEN 45545-2 HL3 · EI 109

EN 50264-3-1 Reduced-Wall Single-Core Rolling Stock CableEN 50264-3-1 0.6/1 kV & 1.8/3 kV reduced-wall e-beam single-core railway cable

Space- and weight-saving reduced-wall single-core railway rolling-stock power and control wire certified to EN 50264-3-1 (`0.6/1 kV` and `1.8/3 kV`, code `M`) with Class 5 tinned copper conductors (0.5–240 mm²) and e-beam cross-linked EI 109 LSZH insulation.

Flame-retardant
Oil-resistant
Outdoor & humid
Approved
Order designation
EN 50264-3-1 600V 1×2.5 M
Outer Ø min
3.0 mm
Outer Ø max
3.3 mm
Weight ≈
31 kg/km
Min. bend R
10 mm
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Voltage rating
0.6/1 & 1.8/3 kV
600 V & 1.8 kV AC (up to 4.5 kV DC)
Fire hazard
HL1 / HL2 / HL3
EN 45545-2 R15 (interior) & R16 (ext.)
Conductor temp.
−40…+90 °C
+90 °C continuous · +120 °C (20,000 h)
Insulation
EI 109 e-beam
Dual-layer reduced-wall e-beam LSZH
Bending radius
3–4 × OD
3 × OD (D ≤ 10 mm) · 4 × OD (D > 10 mm)
Size range
0.5–240 mm²
Single-core control & traction power

Typical values for this cable type, based on EN 50264-3-1 / EN 45545-2 HL1–HL3 — confirmed in the datasheet and quotation for your order.

Application fit

Is EN 50264-3-1 right for your machine?

EN 50264-3-1 replaces thick elastomeric walls (`EN 50264-2-1`) with high-modulus electron-beam cross-linked `EI 109` co-extruded insulation, cutting cable diameter by up to 30 % and weight by up to 25 % in railway switchgear cabinets, traction cubicles and under-frame ducts.

Fixed installation

Suitable

Traction converter cubicles, driver desk harnesses, auxiliary battery feeders and car-body conduits.

VFD inverter to AC motor screened feeder

With conditions

1.8/3 kV class is widely used inside shielded traction inverter cubicles; use screened cable for external runs.

Use EN 50264-3-2 MMS

Trailing & towing

Not suitable

Single-core protected rolling-stock wire; for multi-core external bogie cables, select EN 50264-2-2.

Use EN 50264-2-2

Energy chain / drag chain

Not suitable

For 300 V ultra-thin-wall cabinet and rack wiring (0.5–2.5 mm²), select EN 50306-2.

Use EN 50306-2
Typical machinesTraction converters & HV switchgear cubiclesHigh-speed train & EMU car-body wiringMetro & commuter rail control panelsLocomotive battery & auxiliary DC busesRailway subsystem OEM pre-wired racks

Construction

Layer by layer

Shown: EN 50264-3-1 600 V 1×2.5 M — Class 5 tinned annealed copper conductor and co-extruded reduced-wall electron-beam cross-linked halogen-free polymer insulation (inner dielectric core + outer oil/fuel-resistant EI 109 skin).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 tinned copper conductorFine-stranded tinned annealed copper to EN 60228 Class 5 (0.5 to 240 mm²)EN 60228 Class 5 · EN 50264-3-1
2Inner cross-linked dielectric layerElectron-beam cross-linked halogen-free polyolefin/copolymer primary dielectric layerEN 50264-1 EI 109
3Outer EI 109 / EM 104 skinCo-extruded reduced-wall electron-beam cross-linked outer insulation/sheath resistant to oil, fuel and −40 °C coldEN 50264-3-1 · EN 45545-2 HL3

EN 50264-3-1 600 V (0.6/1 kV, M) — 0.5 to 240 mm²

Reduced-wall single-core control and auxiliary power wire (max. 720/1200 V AC, 900/1800 V DC)

EN 50264-3-1 1800 V (1.8/3 kV, M / MM) — 1.5 to 240 mm²

Reduced-wall medium-voltage traction and DC link feeder cable (max. 2.2/3.6 kV AC, 2.7/5.4 kV DC)

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on EN 50264-3-1 / EN 45545-2 HL1–HL3. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage U0/U
0.6/1 kV ('600 V' class) & 1.8/3 kV ('1800 V' class) AC
Max. DC operating voltage
0.9/1.8 kV DC (for 600 V class) · 2.7/5.4 kV DC (for 1800 V class)
AC test voltage (50 Hz)
3.5 kV AC (600 V class) · 6.5 kV AC (1800 V class) for 5 min
Spark test voltage
6 kV AC (600 V class) · 10 kV AC (1800 V class)

Thermal

Operating temperature range
−40 °C to +90 °C (fixed) · −25 °C to +90 °C (flexing)
Thermal overload rating
+120 °C (20,000 h cumulative life)
Short-circuit temperature
+200 °C max. (5 s) — e-beam cross-linked polymer does not melt

Mechanical

Min. bending radius, fixed
3 × OD (D ≤ 10 mm) · 4 × OD (D > 10 mm)
Reduced wall thickness (600 V)
0.6 mm nominal wall for 0.5–2.5 mm² · 0.7 mm for 4–6 mm² · 0.9 mm for 10–16 mm²
Cut-through & abrasion
High-modulus EI 109 e-beam cross-linked compound passes EN 50305 scrape & notch tests

Resistance

Railway fire safety
EN 45545-2 Hazard Level HL1, HL2 & HL3 (Requirement Sets R15 & R16)
Smoke & halogen-free
EN 61034-2 low smoke · EN 60754-1/2 zero halogen (pH ≥ 4.3, conductivity ≤ 10 µS/mm)
Fluids & ozone
Resistant to IRM 902 mineral oil, IRM 903 diesel fuel, battery acid and ozone per EN 50264-1

Reference standards

Primary standard
EN 50264-3-1 (Reduced wall single-core rolling stock cables)
Compound standard
EN 50264-1 Type EI 109 (insulation) & EM 104 (sheath on 1800 V MM)
Fire testing
EN 45545-2, EN 60332-1-2, EN 60332-3-24 / EN 50305
RoHS & REACH
2011/65/EU (RoHS 2) & EC 1907/2006 compliant

Identification

Insulation colour
Black (standard), Green-Yellow ('G' earth), Blue, Red, White or Grey on request
Surface marking
TEBAOFLEX EN 50264-3-1 600V [Size] M EN 45545-2 HL3
Customs tariff (HS)
8544.49 (≤ 1000 V) / 8544.60 (> 1000 V)

Sizes

22 standard EN 50264-3-1 configurations

Typical EN 50264-3-1 / EN 45545-2 HL1–HL3 outer diameter limits, copper content and cable weight.

Dimensions & weights
Order designationCores × mm² / AWGAWG ≈Outer Ø min
mm
Outer Ø max
mm
Copper
kg/km
Weight ≈
kg/km
Min. bend R
mm
Enquiry
0.6/1 kV (600 V) Reduced-Wall Control & Panel Wires (0.5–6 mm²)
EN 50264-3-1 600V 1×0.5 M1×0.5201.92.1496
EN 50264-3-1 600V 1×0.75 M1×0.75182.12.37127
EN 50264-3-1 600V 1×1.0 M1×1.0182.32.59158
EN 50264-3-1 600V 1×1.5 M1×1.5162.62.814208
EN 50264-3-1 600V 1×2.5 M1×2.5143.03.3243110
EN 50264-3-1 600V 1×4 M1×4123.74.0384712
EN 50264-3-1 600V 1×6 M1×6104.24.6576814
0.6/1 kV (600 V) Reduced-Wall Auxiliary Power Leads (10–240 mm²)
EN 50264-3-1 600V 1×10 M1×1085.45.99611418
EN 50264-3-1 600V 1×16 M1×1666.47.015317421
EN 50264-3-1 600V 1×25 M1×2548.08.724026826
EN 50264-3-1 600V 1×35 M1×3529.310.133636830
EN 50264-3-1 600V 1×50 M1×501/010.911.948052036
EN 50264-3-1 600V 1×70 M1×702/012.713.867271841
EN 50264-3-1 600V 1×95 M1×953/014.415.691295547
EN 50264-3-1 600V 1×120 M1×1204/016.117.51,1521,20552
EN 50264-3-1 600V 1×150 M1×150300 kcmil18.019.61,4401,50059
EN 50264-3-1 600V 1×185 M1×185350 kcmil20.121.81,7761,84565
EN 50264-3-1 600V 1×240 M1×240500 kcmil22.624.62,3042,39074
1.8/3 kV (1800 V) Reduced-Wall Traction & DC Link Feeders
EN 50264-3-1 1800V 1×2.5 M1×2.5144.75.1244915
EN 50264-3-1 1800V 1×10 M1×1087.07.69614223
EN 50264-3-1 1800V 1×35 M1×35210.911.833641235
EN 50264-3-1 1800V 1×95 M1×953/016.117.59121,02552
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are typical values per EN 50264-3-1 / EN 45545-2 HL1–HL3. Minimum fixed bending radius shown is 3 × OD.

Reel check

Will it fit your machine?

A first screen using datasheet values. Engineering confirms drum geometry, acceleration and tension with your quotation.

Check results

Drum core 300 mm ≥ 20 mmBending radius OK (3 × OD 3.3 mm)
Minimum bending radius
10 mm
Min. drum core diameter
≈ 20 mm
Cable weight on drum
1.6 kg
Copper content
1.2 kg
Indicative only: based on the datasheet outer diameter and 3 × OD bending radius. Current derating for wound layers per DIN VDE 0298-4 is assessed separately.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
AC dielectric voltage test3.5 kV AC (50/60 Hz)Every manufactured length
Conductor DC resistanceIEC 60228 / ASTM (tinned copper)Every manufactured length
Sample tests
Flame propagation testIEC 60332-1-2 / UL VW-1 / ISO 6722-1Per production batch
Insulation & sheath material physical propertiesEN 50264-3-1 / EN 45545-2 HL1–HL3Type approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

EN 50264-3-1 / EN 45545-2 HL1–HL3CE · RoHS 2 (2011/65/EU) · REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EN 50264-3-1 600V [Size] M EN 45545-2 HL3
Delivery form
Export wooden drums, reels or coils, cut-to-length on request
Packaging
Heat-treated ISPM-15 timber drums or spools with sealed ends
Conductor / colour options
Custom core counts, stripe combinations or cut harnesses on request

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

How does EN 50264-3-1 achieve a thinner wall than EN 50264-2-1 while keeping a 0.6/1 kV or 1.8/3 kV rating?
EN 50264-3-1 uses high-density electron-beam cross-linked compound Type EI 109 (defined in EN 50264-1), which has higher tensile modulus, cut-through resistance and dielectric strength than conventional vulcanised rubber (EI 101–104). For example, a 1×2.5 mm² 600 V wire has an outer diameter of ~3.3 mm under EN 50264-3-1 versus ~4.1 mm under EN 50264-2-1.
When should I choose EN 50264-3-1 (600 V) vs EN 50306-2 (300 V)?
Choose EN 50306-2 (thin wall, 0.25–0.30 mm insulation, 300 V rating) for high-density low-voltage control and signal wiring from 0.5 to 2.5 mm² inside dry relay racks. Choose EN 50264-3-1 (reduced wall, 0.6/1 kV and 1.8/3 kV, 0.5 to 240 mm²) for 400 V / 750 V / 1500 V auxiliary power, battery buses and general vehicle wiring.
What does the code 'M' or 'MM' mean on EN 50264-3-1 cables?
Single-layer or co-extruded insulated wires are designated 'M' (or 'MG' for green-yellow earth). In the 1800 V (1.8/3 kV) class, an additional outer elastomeric sheath can be applied, designated 'MM'.
Is EN 50264-3-1 resistant to soldering-iron heat and short circuits?
Yes. Because the EI 109 insulation is thermoset via electron-beam irradiation, it will not melt or flow at soldering temperatures or during a +200 °C short circuit.

Request a quote

Get an engineering quote for EN 50264-3-1

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EN 50264-3-1 Reduced-Wall Single-Core Rolling Stock Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 