Immersion & wet locations
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Product
REF 15689 (1,000V/250V 4×2.5mm² Shielded Power + 20×0.6mm² XLPE/PUR Aquaculture Cable) & REF 59436 (2×SMF + 2×RS-422 + Power Aramid-Braided Halieutic Observation Cable) (IEC 60228 / Subsea, 0.6/1 kV, -15 °C to +70 °C).
Typical values for this cable type, based on IEC 60228 / Subsea Aquaculture & Halieutic Observation — confirmed in the datasheet and quotation for your order.
Application fit
REF 15689 (1,000V/250V 4×2.5mm² Shielded Power + 20×0.6mm² XLPE/PUR Aquaculture Cable) & REF 59436 (2×SMF + 2×RS-422 + Power Aramid-Braided Halieutic Observation Cable) (IEC 60228 / Subsea, 0.6/1 kV, -15 °C to +70 °C).
Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.
Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.
Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.
High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.
Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.
Use Drag-Chain Servo CableConstruction
Shown: REF 15689 & REF 59436 (AQUACULTURE & HALIEUTIC) (IEC 60228 / Subsea Aquaculture & Halieutic Observation) featuring screened 1,000 v power unit (4×2.5 mm²), 250 v control & sensor ring (20×0.6 mm²) and subsea polyurethane outer sheath (ø15.7 mm) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Screened 1,000 V Power Unit (4×2.5 mm²) | Central 4×2.5 mm² flexible tinned Cu XLPE cores enclosed in a tinned copper wire braid |
| 2 | 250 V Control & Sensor Ring (20×0.6 mm²) | 20 concentric 0.6 mm² flexible tinned Cu XLPE cores (≤36 Ω/km) around power core |
| 3 | Halieutic Electro-Optic Option (REF 59436) | 2×SMF + 2×(2×0.25 mm² 100 Ω RS-422) + 1×(2×0.75)S + 5×0.25 + 140 daN aramid braid |
| 4 | Subsea Polyurethane Outer Sheath (Ø15.7 mm) | Black abrasion- and hydrolysis-resistant PUR jacket (–15 °C to +70 °C, 0.39 kg/m) |
Built to IEC 60228 / Subsea Aquaculture & Halieutic Observation with screened 1,000 v power unit (4×2.5 mm²) and subsea polyurethane outer sheath (ø15.7 mm)
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60228 / Subsea Aquaculture & Halieutic Observation for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 15689 & REF 59436 (AQUACULTURE & HALIEUTIC) Construction Schedule (−15…+70 °C) | |||||||
| REF 15689 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 15689 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 15689 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −15…+70 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −15…+70 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −15…+70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60228 / Subsea Aquaculture & Halieutic Observation) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60228 / Subsea Aquaculture & Halieutic Observation tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60228 / Subsea Aquaculture & Halieutic Observation) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60228 / Subsea Aquaculture & Halieutic Observation) | Verified submersion integrity, tensile load and thermal stability across −15…+70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.