Contact
High-modulus aramid subsea mooring & anti-biofouling cable3,000 daN & 35,000 daNNon-Magnetic Aramid Core50% Anti-Fouling Cu Braid

REF 22399 & REF 57912 (3–35t) Aramid Mooring & Anti-Fouling CableSubsea Non-Magnetic · 300/500 V · High-modulus aramid subsea mooring & anti-biofouling

REF 22399 (3-Ton High-Modulus Aramid PUR Cable with 50% Anti-Fouling Copper Outer Braid) & REF 57912 (35-Ton Anti-Giratory Double-HDPE Aramid Instrumentation Basket Cable) (Subsea Non-Magnetic, 300/500 V, -20 °C to +70 °C).

Water-resistant
Anti-torsion braid
Outdoor & humid
Ozone, UV & moisture
Order designation
REF 22399 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
Tested per Subsea Non-Magnetic
Operating temp.
−20…+70 °C
Continuous subsea & marine service
Min. bend radius
12 × OD
Dynamic sheave & fixed routing
Core / conductor
3,000
Low-stretch non-magnetic high-modulus
Outer protection
50% Cu Braid
Anti-fouling bare Cu exterior braid
Standard
Subsea
Subsea Non-Magnetic Aramid Mooring

Typical values for this cable type, based on Subsea Non-Magnetic Aramid Mooring & Biofouling Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is REF 22399 & REF 57912 (MOORING & ANTIFOULING) right for your machine?

REF 22399 (3-Ton High-Modulus Aramid PUR Cable with 50% Anti-Fouling Copper Outer Braid) & REF 57912 (35-Ton Anti-Giratory Double-HDPE Aramid Instrumentation Basket Cable) (Subsea Non-Magnetic, 300/500 V, -20 °C to +70 °C).

Immersion & wet locations

Suitable

Water-blocked core matrix and hydrolysis-resistant subsea jacketing withstand continuous deepwater hydrostatic pressure.

Vertical / spreader reel

Suitable

Torque-balanced aramid or contra-helical steel armour supports vertical winch deployment without hockling.

Offshore platform & shipboard deck trays

Suitable

Marine-grade outer sheath and armour package resist LARS sheave abrasion, UV exposure and salt-spray corrosion.

Trailing & towing

Suitable

High tensile breaking strength supports underwater towing, ROV excursion and seabed plough/trencher duty.

Energy chain / drag chain

Not suitable

Subsea umbilical and tow construction is not intended for high-cycle indoor factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableWork-Class & Observation ROV SystemsOffshore Wind & Subsea Power GridsOceanographic, Sonar & Seismic SurveyCommercial Diving & Subsea Intervention

Construction

Layer by layer

Shown: REF 22399 & REF 57912 (MOORING & ANTIFOULING) (Subsea Non-Magnetic Aramid Mooring & Biofouling Standard) featuring high-modulus aramid core (3,000 / 35,000 dan), polyurethane / double-hdpe sheathing and 50% anti-fouling bare copper outer braid (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1High-Modulus Aramid Core (3,000 / 35,000 daN)Low-stretch (≤2.3–2.4% at break) non-magnetic aramid core rated 3 t (22399) / 35 t (57912)
2Polyurethane / Double-HDPE SheathingExtruded PUR sheath (REF 22399) or inner HDPE + anti-torsion aramid + outer HDPE (57912)
350% Anti-Fouling Bare Copper Outer BraidExterior plain copper wire braid on REF 22399 inhibiting barnacle & marine growth (Ø 8.9 mm)

REF 22399 & REF 57912 (MOORING & ANTIFOULING) — Standard Subsea & Marine Execution

Built to Subsea Non-Magnetic Aramid Mooring & Biofouling Standard with high-modulus aramid core (3,000 / 35,000 dan) and 50% anti-fouling bare copper outer braid

REF 22399 & REF 57912 (MOORING & ANTIFOULING) — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

REF 22399 & REF 57912 (MOORING & ANTIFOULING) — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Subsea Non-Magnetic Aramid Mooring & Biofouling Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
300/500 V (Subsea Non-Magnetic Aramid Mooring & Biofouling Standard)
Core / conductor construction
High-Modulus Aramid Core (3,000 / 35,000 daN) — Low-stretch (≤2.3–2.4% at break) non-magnetic aramid core rated 3 t (22399) / 35 t (57912)
Primary dielectric / buffering
Polyurethane / Double-HDPE Sheathing — Extruded PUR sheath (REF 22399) or inner HDPE + anti-torsion aramid + outer HDPE (57912)

Thermal

Continuous operating temperature
−20…+70 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per Subsea Non-Magnetic Aramid Mooring & Biofouling Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
50% Anti-Fouling Bare Copper Outer Braid — Exterior plain copper wire braid on REF 22399 inhibiting barnacle & marine growth (Ø 8.9 mm)
Minimum bending radius
12 × OD
Hydrostatic, tensile & crush duty
Polyurethane / Double-HDPE Sheathing — Extruded PUR sheath (REF 22399) or inner HDPE + anti-torsion aramid + outer HDPE (57912)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per Subsea Non-Magnetic Aramid Mooring & Biofouling Standard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per Subsea Non-Magnetic Aramid Mooring & Biofouling Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
Subsea Non-Magnetic Aramid Mooring & Biofouling Standard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
REF 22399 & REF 57912 (MOORING & ANTIFOULING)
Sheath colour & metre marking
Continuous metre-marked black outer finish (50% Cu Braid / Double HDPE)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard REF 22399 & REF 57912 (MOORING & ANTIFOULING) subsea & marine configurations

Manufactured to Subsea Non-Magnetic Aramid Mooring & Biofouling Standard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
REF 22399 & REF 57912 (MOORING & ANTIFOULING) Construction Schedule (−20…+70 °C)
REF 22399 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
REF 22399 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
REF 22399 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per Subsea Non-Magnetic Aramid Mooring & Biofouling Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (Subsea Non-Magnetic Aramid Mooring & Biofouling Standard)DC resistance at 20 °C / optical attenuation and outer diameter within Subsea Non-Magnetic Aramid Mooring & Biofouling Standard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (Subsea Non-Magnetic Aramid Mooring & Biofouling Standard)Zero dielectric breakdown and verified insulation resistance for 300/500 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (Subsea Non-Magnetic Aramid Mooring & Biofouling Standard)Verified submersion integrity, tensile load and thermal stability across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Subsea Non-Magnetic CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX REF 22399 & REF 57912 (MOORING & ANTIFOULING) Subsea Non-Magnetic 300/500 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define REF 22399 & REF 57912 (MOORING & ANTIFOULING) (REF 22399 & REF 57912 (3–35t) Aramid Mooring & Anti-Fouling Cable)?
REF 22399 & REF 57912 (MOORING & ANTIFOULING) (REF 22399 & REF 57912 (3–35t) Aramid Mooring & Anti-Fouling Cable) is manufactured in accordance with Subsea Non-Magnetic Aramid Mooring & Biofouling Standard for 300/500 V service over -20 °C to +70 °C. Its 3-layer construction comprises high-modulus aramid core (3,000 / 35,000 dan), polyurethane / double-hdpe sheathing and 50% anti-fouling bare copper outer braid.
What is the minimum bending radius and operating temperature range for REF 22399 & REF 57912 (MOORING & ANTIFOULING)?
The minimum bending radius for REF 22399 & REF 57912 (MOORING & ANTIFOULING) is 12 × OD across its continuous operating temperature range of -20 °C to +70 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of REF 22399 & REF 57912 (MOORING & ANTIFOULING) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) High-Modulus Aramid Core (3,000 / 35,000 daN) — Low-stretch (≤2.3–2.4% at break) non-magnetic aramid core rated 3 t (22399) / 35 t (57912); (02) Polyurethane / Double-HDPE Sheathing — Extruded PUR sheath (REF 22399) or inner HDPE + anti-torsion aramid + outer HDPE (57912); (03) 50% Anti-Fouling Bare Copper Outer Braid — Exterior plain copper wire braid on REF 22399 inhibiting barnacle & marine growth (Ø 8.9 mm).
What factory test certificates are supplied with REF 22399 & REF 57912 (MOORING & ANTIFOULING)?
Every production drum of REF 22399 & REF 57912 (MOORING & ANTIFOULING) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per Subsea Non-Magnetic Aramid Mooring & Biofouling Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for REF 22399 & REF 57912 (MOORING & ANTIFOULING)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

REF 22399 & REF 57912 (3–35t) Aramid Mooring & Anti-Fouling Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote