EMC-shielded wind turbine converter & VFD drive cableUL 2277 WTTC / UL 44 RHW-21,000 V WTTC / 2,000 V RHW-2 (-40 toCold-Resistant TPE Elastomeric Outer

VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor CableUL 2277 WTTC / UL 44 RHW-2 — 1,000 V WTTC / 2,000 V RHW-2 — -40 to +90 °C Wind Turbine Cable

VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor Cable (UL 2277 WTTC / UL 44 RHW-2, 1,000 V WTTC / 2,000 V RHW-2, -40 to +90 °C, min. bend radius 6 × OD).

Anti-torsion braid
EMC screen
Oil-resistant
Approved
Order designation
VFD 2XL WTTC 1000V 4G16 / 3×16+3G2.5
Outer Ø ≈
21.8 mm
Net weight ≈
790 kg/km
Max. pulling ≈
9.5 kN
Core / stranding
IEC 60228 Class 5 / Class K Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1,000 V WTTC / 2
Tested per UL 2277 WTTC / UL 44 RHW-2
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 5 Tinned C
Finely stranded tinned copper (3 phase c
Outer protection
Cold-Resistant T
Flexible -40 °C TPE sheath for yaw, pitc
Standard
UL 2277 WTTC / U
UL Subject 2277 WTTC 1,000 V & UL 44 RHW

Typical values for this cable type, based on UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is VFD 2XL WTTC 1000V / 2kV RHW-2 right for your machine?

VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor Cable (UL 2277 WTTC / UL 44 RHW-2, 1,000 V WTTC / 2,000 V RHW-2, -40 to +90 °C, min. bend radius 6 × OD).

VFD inverter to AC motor screened feeder

Suitable

Symmetrical 3+3 split grounds or 100% foil + 85% tinned copper braid shield give a low-impedance return path for PWM drive currents.

Motor stator, traction & converter leads

Suitable

Extra-thick 2XL XLPE / RHW-2 insulation withstands high dV/dt voltage spikes and corona discharge from IGBT wind converters.

Free-hanging vertical run

Suitable

Class 5 / Class K flexible copper conductors and −40 °C TPE/CPE/PVC jackets handle nacelle vibration, tray routing and drip-loop torsion.

Fixed installation

Suitable

Dual-listed to UL Subject 2277 Type WTTC (1,000 V), UL 1277 TC-ER (600 V) and UL 44 RHW-2 (2,000 V) for raceway-free nacelle installation.

Motorised monospiral reel

Not suitable

Wind converter VFD feeder cable is not designed for continuous mobile reeling drums.

Use Spreader Reel Cable
Typical machinesRenewable Energy & EV ChargingWind Turbine Main Power Converter & Generator DrivesElectric Yaw Drive & Blade Pitch Servo VFD MotorsNacelle Hydraulic Pump, Cooling Fan & Auxiliary VFDsUL 2277 WTTC 1,000 V & 2,000 V Renewable Drive Systems

Construction

Layer by layer

Shown: VFD 2XL WTTC 1000V / 2kV RHW-2 (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification) featuring class 5 tinned copper conductors (4 cores), extra-thick 2xl xlpe (xhhw-2 / rhw-2) insulation and cold-resistant tpe elastomeric outer jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Tinned Copper Conductors (4 CoreFinely stranded tinned copper (3 phase cores + 1 green/yellow ground)
2Extra-Thick 2XL XLPE (XHHW-2 / RHW-2) InHeavy-wall XLPE withstanding high dV/dt PWM VFD voltage spikes
3100% Al/PET Foil + 85% Tinned Cu Braid SDual 100%-coverage foil and braid shield for full-spectrum EMC
4Cold-Resistant TPE Elastomeric Outer JacFlexible -40 °C TPE sheath for yaw, pitch and pump VFD motors

VFD 2XL WTTC 1000V / 2kV RHW-2 — Standard Wind Turbine Execution

Built to UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification with class 5 tinned copper conductors (4 cores) and cold-resistant tpe elastomeric outer jacket

VFD 2XL WTTC 1000V / 2kV RHW-2 — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

VFD 2XL WTTC 1000V / 2kV RHW-2 — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1,000 V WTTC / 2,000 V RHW-2 (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification)
Core / conductor construction
Class 5 Tinned Copper Conductors (4 Cores) — Finely stranded tinned copper (3 phase cores + 1 green/yellow ground)
Primary dielectric / insulation
Extra-Thick 2XL XLPE (XHHW-2 / RHW-2) Insulation — Heavy-wall XLPE withstanding high dV/dt PWM VFD voltage spikes

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Cold-Resistant TPE Elastomeric Outer Jacket — Flexible -40 °C TPE sheath for yaw, pitch and pump VFD motors
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
100% Al/PET Foil + 85% Tinned Cu Braid Shield — Dual 100%-coverage foil and braid shield for full-spectrum EMC

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
VFD 2XL WTTC 1000V / 2kV RHW-2
Sheath colour & metre marking
Continuous metre-marked black outer finish (Cold-Resistant T)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard VFD 2XL WTTC 1000V / 2kV RHW-2 wind turbine configurations

Manufactured to UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
VFD 2XL WTTC 1000V / 2kV RHW-2 Construction Schedule (−40…+90 °C)
VFD 2XL WTTC 1000V 4G16 / 3×16+3G2.54G16 mm² (or 3×6 AWG + 3G10 AWG)IEC 60228 Class 5 / Class K Cu21.87909.5130
VFD 2XL WTTC 1000V 4G50 / 3×50+3G104G50 mm² (or 3×1 AWG + 3G6 AWG)IEC 60228 Class 5 / Class K Cu31.42,14022.5190
VFD 2XL WTTC 1000V 3×150+3G25 VFD3×150 + 3G25 mm² (or 3×350 kcmil)IEC 60228 Class 5 / Class K Cu47.25,48058.0285
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification)DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification)Zero dielectric breakdown and verified insulation resistance for 1,000 V WTTC / 2,000 V RHW-2 ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 2277 WTTC / UL 44 RHW-2 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX VFD 2XL WTTC 1000V / 2kV RHW-2 UL 2277 WTTC / UL 44 RHW-2 1,000 V WTTC / 2,000 V RHW-2 CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define VFD 2XL WTTC 1000V / 2kV RHW-2 (VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor Cable)?
VFD 2XL WTTC 1000V / 2kV RHW-2 (VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor Cable) is manufactured in accordance with UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification for 1,000 V WTTC / 2,000 V RHW-2 wind turbine service over -40 to +90 °C. Its 4-layer construction comprises class 5 tinned copper conductors (4 cores), extra-thick 2xl xlpe (xhhw-2 / rhw-2) insulation and cold-resistant tpe elastomeric outer jacket.
What is the minimum bending radius and operating temperature range for VFD 2XL WTTC 1000V / 2kV RHW-2?
The minimum bending radius for VFD 2XL WTTC 1000V / 2kV RHW-2 is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of VFD 2XL WTTC 1000V / 2kV RHW-2 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Tinned Copper Conductors (4 Cores) — Finely stranded tinned copper (3 phase cores + 1 green/yellow ground); (02) Extra-Thick 2XL XLPE (XHHW-2 / RHW-2) Insulation — Heavy-wall XLPE withstanding high dV/dt PWM VFD voltage spikes; (03) 100% Al/PET Foil + 85% Tinned Cu Braid Shield — Dual 100%-coverage foil and braid shield for full-spectrum EMC; (04) Cold-Resistant TPE Elastomeric Outer Jacket — Flexible -40 °C TPE sheath for yaw, pitch and pump VFD motors.
What factory test certificates are supplied with VFD 2XL WTTC 1000V / 2kV RHW-2?
Every production drum of VFD 2XL WTTC 1000V / 2kV RHW-2 undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per UL Subject 2277 WTTC 1,000 V & UL 44 RHW-2 2,000 V Extra-Thick 2XL XLPE Double-Shielded VFD Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for VFD 2XL WTTC 1000V / 2kV RHW-2

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

VFD 2XL WTTC 1000V / 2kV RHW-2 VFD 2XL 1,000 V UL WTTC / 2,000 V RHW-2 Extra-Thick XLPE Foil + 85% TCWB Double-Shielded Wind VFD Motor Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote