Contact

PWR AFR PUR+LUM 0.6/1 kV Photoluminescent Power CableIEC 60502-1 / DIN VDE 0250 · 0.6/1 kV · -40 °C to +90 °C high-visibility mobile trailing cable

PWR AFR PUR+LUM 0.6/1 kV halogen-free mobile trailing and reeling power cable featuring Class 5 copper phase, split PE and pilot cores with XLPE insulation, aramid reinforcement braid and a photoluminescent retroreflective yellow PUR sheath.

Anti-torsion braid
Oil-resistant
Flame-retardant
Outdoor & humid
Order designation
PWR AFR PUR+LUM 3×25+3×6+2×1.0
Outer Ø ≈
28.2 mm
Weight ≈
1,390 kg/km
Tensile load ≈
6.5 kN
Core / stranding
Class 5 Cu + aramid braid
All sizes (4)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
U0/U AC mobile power + pilot
Operating temp.
−40…+90 °C
Continuous thermal operating range
Min. bend radius
6–10 × OD
Installed / dynamic routing limit
Core / conductor
Class 5 Cu
3×Phase + 3×PE + 2×Pilot
Outer protection
PUR+LUM Yellow
Photoluminescent & reflective PUR
Standard
IEC 60502-1
IEC 60502-1 / EN 50525-2-21

Typical values for this cable type, based on IEC 60502-1 / EN 50525-2-21 — confirmed in the datasheet and quotation for your order.

Application fit

Is PWR AFR PUR+LUM right for your machine?

PWR AFR PUR+LUM 0.6/1 kV halogen-free mobile trailing and reeling power cable featuring Class 5 copper phase, split PE and pilot cores with XLPE insulation, aramid reinforcement braid and a photoluminescent retroreflective yellow PUR sheath.

Trailing & towing

Suitable

Photoluminescent and retroreflective yellow TMPU jacket prevents vehicle run-over in dark tunnels and pits.

TBM gantry & advancing tunnel reel

Suitable

Halogen-free flame-retardant construction for tunnel boring machines, underground portals and emergency power.

Motorised monospiral reel

Suitable

Aramid load-bearing reinforcement braid supports horizontal reeling and mobile generator payouts.

Mine roadway & tunnel wall hangers

Suitable

High-visibility optical safety sheath remains clearly visible under headlamp beams and power blackouts.

Typical machinesMining & TunnellingTunnelling, TBM & Underground Civil EngineeringOpen-Pit & Underground Mining Mobile EquipmentPort Quayside, Airport Apron & Night-Shift OperationsEmergency Power, Defence & Mobile Generator Fleets

Construction

Layer by layer

Shown: PWR AFR PUR+LUM (IEC 60502-1 / EN 50525-2-21) featuring main power cores (3x25 mm²), split pe cores (3x6 mm²) and pur+lum high-visibility sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Main Power Cores (3x25 mm²)Class 5 flexible plain annealed copper phase conductors with crosslinked polyethylene (XLPE) insulationIEC 60502-1 / EN 50525-2-21
2Split PE Cores (3x6 mm²)Three symmetrical green/yellow XLPE-insulated protective earth conductors positioned in the outer intersticesIEC 60502-1 / EN 50525-2-21
3Pilot / Control Cores (2x1.0 mm²)Two XLPE-insulated flexible plain copper pilot cores for continuity and control monitoringIEC 60502-1 / EN 50525-2-21
4Aramid Reinforcement BraidHigh-tenacity braided aramid yarn reinforcement layer absorbing tensile and torsional reeling/trailing loadsIEC 60502-1 / EN 50525-2-21
5PUR+LUM High-Visibility SheathHalogen-free yellow thermoplastic polyurethane (TMPU) outer sheath with integrated photoluminescent and retroreflective elementsIEC 60502-1 / EN 50525-2-21

PWR AFR PUR+LUM — Standard Execution

Built to IEC 60502-1 / EN 50525-2-21 with main power cores (3x25 mm²) and pur+lum high-visibility sheath

PWR AFR PUR+LUM — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

PWR AFR PUR+LUM — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 / EN 50525-2-21. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60502-1 / EN 50525-2-21)
Core / conductor construction
Main Power Cores (3x25 mm²) — Class 5 flexible plain annealed copper phase conductors with crosslinked polyethylene (XLPE) insulation
Primary dielectric / insulation
Split PE Cores (3x6 mm²) — Three symmetrical green/yellow XLPE-insulated protective earth conductors positioned in the outer interstices

Thermal

Continuous operating temperature
−40…+90 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
PUR+LUM High-Visibility Sheath — Halogen-free yellow thermoplastic polyurethane (TMPU) outer sheath with integrated photoluminescent and retroreflective elements
Minimum bending radius
6–10 × OD
Structural layer count
5 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per IEC 60502-1 / EN 50525-2-21
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 / EN 50525-2-21
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
PWR AFR PUR+LUM
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

4 standard PWR AFR PUR+LUM configurations

Manufactured to IEC 60502-1 / EN 50525-2-21 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
PWR AFR PUR+LUM Construction Schedule (−40…+90 °C)
PWR AFR PUR+LUM 3×16+3×4+2×1.03×16 + 3×4 + 2×1.0 mm²Class 5 Cu + aramid braid24.59804.5150
PWR AFR PUR+LUM 3×25+3×6+2×1.03×25 + 3×6 + 2×1.0 mm²Class 5 Cu + aramid braid28.21,3906.5170
PWR AFR PUR+LUM 3×35+3×6+2×1.03×35 + 3×6 + 2×1.0 mm²Class 5 Cu + aramid braid31.41,7808.5190
PWR AFR PUR+LUM 3×50+3×10+2×1.53×50 + 3×10 + 2×1.5 mm²Class 5 Cu + aramid braid35.82,42011.5215
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per IEC 60502-1 / EN 50525-2-21.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (IEC 60502-1 / EN 50525-2-21)Electrical parameters and outer diameter within IEC 60502-1 / EN 50525-2-21 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (IEC 60502-1 / EN 50525-2-21)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (IEC 60502-1 / EN 50525-2-21)Verified structural and dielectric integrity across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX PWR AFR PUR+LUM IEC 60502-1 0.6/1 kV CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is PWR AFR PUR+LUM engineered for?
PWR AFR PUR+LUM 0.6/1 kV halogen-free mobile trailing and reeling power cable featuring Class 5 copper phase, split PE and pilot cores with XLPE insulation, aramid reinforcement braid and a photoluminescent retroreflective yellow PUR sheath. It is built to IEC 60502-1 / EN 50525-2-21 for tunnelling, tbm & underground civil engineering and open-pit & underground mining mobile equipment.
What are the minimum bending radius and operating temperature range for PWR AFR PUR+LUM?
The minimum bending radius for PWR AFR PUR+LUM is 6–10 × OD across its continuous operating temperature range of -40 °C to +90 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of PWR AFR PUR+LUM arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Main Power Cores (3x25 mm²) (Class 5 flexible plain annealed copper phase conductors with crosslinked polyethylene (XLPE) insulation); (02) Split PE Cores (3x6 mm²) (Three symmetrical green/yellow XLPE-insulated protective earth conductors positioned in the outer interstices); (03) Pilot / Control Cores (2x1.0 mm²) (Two XLPE-insulated flexible plain copper pilot cores for continuity and control monitoring); (04) Aramid Reinforcement Braid (High-tenacity braided aramid yarn reinforcement layer absorbing tensile and torsional reeling/trailing loads); (05) PUR+LUM High-Visibility Sheath (Halogen-free yellow thermoplastic polyurethane (TMPU) outer sheath with integrated photoluminescent and retroreflective elements).
What factory test certificates are supplied with PWR AFR PUR+LUM?
Every production drum of PWR AFR PUR+LUM undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per IEC 60502-1 / EN 50525-2-21, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for PWR AFR PUR+LUM

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

PWR AFR PUR+LUM 0.6/1 kV Photoluminescent Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp