Switchgear & control cabinet wiring
Primary duty for internal RF module jumpers, PCB-to-bulkhead pigtails, and test instrumentation.
Product
RG-316 (MIL-DTL-17/113-RG316 / M17/138) is a miniature 50 Ω high-temperature fluoropolymer RF coaxial cable with a 2.50 mm outer diameter. Engineered with a 7×0.17 mm (26 AWG) silver-plated copper-clad steel (SCCS) conductor, solid PTFE dielectric
Typical values for this cable type, based on MIL-DTL-17/113-RG316 (M17/138) — confirmed in the datasheet and quotation for your order.
Application fit
Specified for compact internal RF interconnects, SMA/SMB/MMCX/BNC high-temperature pigtails, avionics transceivers, phased-array test racks, and military radio harnesses.
Primary duty for internal RF module jumpers, PCB-to-bulkhead pigtails, and test instrumentation.
+200 °C FEP jacket withstands wave/reflow heat and dense avionics bay routing without melting.
High tensile strength of the 7×0.17 mm SCCS center conductor resists breakage on test bench leads.
Suitable for short-stroke instrument flex; use PUR drag-chain cables for multi-million-cycle tracks.
S 368 CConstruction
26 AWG (7×0.17 mm) silver-plated copper-clad steel center, Ø 1.52 mm solid PTFE dielectric, 95 % silver-plated copper braid, and Ø 2.50 mm
| # | Layer | Material & reference |
|---|---|---|
| 1 | Center conductor (26 AWG SCCS) | 7×0.17 mm (Ø 0.51 mm) silver-plated copper-clad steel wire per ASTM B501MIL-DTL-17/113 |
| 2 | Solid PTFE fluoropolymer dielectric | Extruded virgin polytetrafluoroethylene (PTFE), Ø 1.52 mm ± 0.05 mmMIL-DTL-17/113 |
| 3 | Silver-plated copper (SPC) shield | 38 AWG silver-plated copper wire braid (≥ 95 % optical coverage; double braid on RG-316D)MIL-DTL-17/113 |
| 4 | Fluorinated ethylene-propylene (FEP) | Extruded high-temperature FEP fluoropolymer outer sheath, translucent brown (Ø 2.50 mm)MIL-DTL-17/113 |
Single silver-plated copper braid, Ø 2.50 mm FEP jacket, 50 Ω miniature high-temperature RF coax.
Double silver-plated copper braids (> 90 dB shielding), Ø 2.90 mm FEP jacket for low-leakage 6 GHz links.
Technical data
Sizes
Dimensional, physical and high-frequency electrical parameters for RG-316 per MIL-DTL-17/113-RG316 (M17/138).
| Order designation | Construction / Variant | Conductor | Outer Ø ≈ mm | Metal kg/km | Weight ≈ kg/km | Min. bend R fixed mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Standard RG-316 variants | |||||||
| RG-316/U (M17/113-RG316) Single Shield | 50 Ω Single SPC Braid (FEP) | 26 AWG (7×0.17 SCCS) | 2.50 | 7.8 | 15.6 | 12 | |
| M17/138-00001 Low-Loss RG-316 | 50 Ω Tight-Tol SPC Braid (FEP) | 26 AWG (7×0.17 SCCS) | 2.50 | 8.2 | 16.0 | 12 | |
| RG-316D / RD-316 (M17/152) Double Shield | 50 Ω Double SPC Braid (FEP) | 26 AWG (7×0.17 SCCS) | 2.90 | 14.5 | 23.0 | 14 | |
| RG-316 PFA (+250 °C Jacket) | 50 Ω Single SPC Braid (PFA) | 26 AWG (7×0.17 SCCS) | 2.50 | 7.8 | 16.2 | 12 | |
| Frequency | Nominal attenuation dB / 100 m | Nominal attenuation dB / 100 ft | Max. CW RF power W (@ 40 °C) | Impedance Z₀ Ω | Velocity VoP % |
|---|---|---|---|---|---|
| 50 MHz | 24.6 | 7.50 | 560 | 50 | 69.5 |
| 100 MHz | 36.1 | 11.00 | 380 | 50 | 69.5 |
| 400 MHz | 68.9 | 21.00 | 180 | 50 | 69.5 |
| 1000 MHz (1 GHz) | 115.0 | 35.05 | 110 | 50 | 69.5 |
| 2400 MHz (2.4 GHz) | 183.7 | 55.99 | 68 | 50 | 69.5 |
| 3000 MHz (3 GHz) | 206.7 | 63.00 | 58 | 50 | 69.5 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Sweep return loss & characteristic impedance | 50 Ω ± 2 Ω; VSWR ≤ 1.25:1 across DC–3 GHz | Every spool |
| Dielectric spark & AC voltage withstand | 2.0 kV rms at 60 Hz without breakdown | 100 % of length |
| Sample tests | ||
| Attenuation at 400 MHz, 1 GHz & 3 GHz | Complies with MIL-DTL-17/113 maximum attenuation limits | Per production lot |
| Thermal shock (-55 to +200 °C) & cold bend | Zero PTFE/FEP cracking or dimensional flow per MIL-DTL-17 | Qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.